115 research outputs found

    Association of Retinal Vascular Caliber and Age-Related Macular Degeneration in Patients With the Acquired Immunodeficiency Syndrome.

    Get PDF
    PurposeTo evaluate the relationship between retinal vascular caliber and AMD in patients with AIDS.MethodsParticipants enrolled in the Longitudinal Study of the Ocular Complications of AIDS had retinal photographs taken at enrollment. Retinal vascular caliber (central retinal artery equivalent [CRAE] and central retinal vein equivalent [CRVE]) and intermediate-stage AMD were determined from these retinal photographs. Photographs were evaluated by graders at a centralized reading center, using the Age-Related Eye Disease Study grading system for AMD and semiautomated techniques for evaluating retinal vascular caliber.ResultsOf the 1171 participants evaluated, 110 (9.4%) had AMD and 1061 (90.6%) did not. Compared with participants without AMD, participants with AMD had larger mean CRAEs (151 ± 16 Όm versus 147 ± 16 Όm; P = 0.009) and mean CRVEs (228 ± 24 Όm versus 223 ± 25 Όm; P = 0.02). The unadjusted differences were: CRAE, 4.3 Όm (95% confidence interval [CI] 1.1-7.5; P = 0.009) and CRVE, 5.5 Όm (95% CI 0.7-10.3; P = 0.02). After adjustment for age, race/ethnicity, sex, human immunodeficiency syndrome (HIV) transmission category, smoking, enrollment and nadir CD4+ T cells, and enrollment and maximum HIV load, the differences between patients with and without AMD were as follows: CRAE, 5.4 Όm (95% CI 2.3-8.5; P = 0.001) and CRVE, 6.0 Όm (95% CI 1.4-10.6; P = 0.01).ConclusionsIn patients with AIDS, AMD is associated with greater retinal arteriolar and venular calibers, suggesting a role for shared pathogenic mechanisms, such as persistent systemic inflammation

    Quality Control Measures over 30 Years in a Multicenter Clinical Study: Results from the Diabetes Control and Complications Trial / Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study.

    Get PDF
    Implementation of multicenter and/or longitudinal studies requires an effective quality assurance program to identify trends, data inconsistencies and process variability of results over time. The Diabetes Control and Complications Trial (DCCT) and the follow-up Epidemiology of Diabetes Interventions and Complications (EDIC) study represent over 30 years of data collection among a cohort of participants across 27 clinical centers. The quality assurance plan is overseen by the Data Coordinating Center and is implemented across the clinical centers and central reading units. Each central unit incorporates specific DCCT/EDIC quality monitoring activities into their routine quality assurance plan. The results are reviewed by a data quality assurance committee whose function is to identify variances in quality that may impact study results from the central units as well as within and across clinical centers, and to recommend implementation of corrective procedures when necessary. Over the 30-year period, changes to the methods, equipment, or clinical procedures have been required to keep procedures current and ensure continued collection of scientifically valid and clinically relevant results. Pilot testing to compare historic processes with contemporary alternatives is performed and comparability is validated prior to incorporation of new procedures into the study. Details of the quality assurance plan across and within the clinical and central reading units are described, and quality outcomes for core measures analyzed by the central reading units (e.g. biochemical samples, fundus photographs, ECGs) are presented

    A Genome-Wide Association Study of Diabetic Kidney Disease in Subjects With Type 2 Diabetes

    Get PDF
    dentification of sequence variants robustly associated with predisposition to diabetic kidney disease (DKD) has the potential to provide insights into the pathophysiological mechanisms responsible. We conducted a genome-wide association study (GWAS) of DKD in type 2 diabetes (T2D) using eight complementary dichotomous and quantitative DKD phenotypes: the principal dichotomous analysis involved 5,717 T2D subjects, 3,345 with DKD. Promising association signals were evaluated in up to 26,827 subjects with T2D (12,710 with DKD). A combined T1D+T2D GWAS was performed using complementary data available for subjects with T1D, which, with replication samples, involved up to 40,340 subjects with diabetes (18,582 with DKD). Analysis of specific DKD phenotypes identified a novel signal near GABRR1 (rs9942471, P = 4.5 x 10(-8)) associated with microalbuminuria in European T2D case subjects. However, no replication of this signal was observed in Asian subjects with T2D or in the equivalent T1D analysis. There was only limited support, in this substantially enlarged analysis, for association at previously reported DKD signals, except for those at UMOD and PRKAG2, both associated with estimated glomerular filtration rate. We conclude that, despite challenges in addressing phenotypic heterogeneity, access to increased sample sizes will continue to provide more robust inference regarding risk variant discovery for DKD.Peer reviewe

    Quantitative analysis of the Stratus optical coherence tomography fast macular thickness map reports

    No full text
    The cross sectional optical coherence tomography images have an important role in evaluating retinal diseases. The reports generated by the Stratus fast macular thickness scan protocol are useful for both clinical and research purposes. The centerpoint thickness is an important outcome measure for many therapeutic trials related to macular disease. The data is susceptible to artifacts such as decentration and boundary line errors and could be potentially erroneous. An understanding of how the data is generated is essential before utilizing the data. This article describes the interpretation of the fast macular thickness map report, assessment of the quality of an optical coherence tomography image and identification of the artifacts that could influence the numeric data

    Quantitative assessment of optic nerve changes in patients with diabetic macular edema treated with fluocinolone acetonide vitreous implants

    No full text
    BACKGROUND AND OBJECTIVE: To evaluate glaucomatous changes in patients with diabetic macular edema (DME) treated with intravitreal implants releasing 0.2 ?g/day or 0.5 ?g/day fluocinolone acetonide (FAc) (Iluvien 0.2 ?g/day; Alimera Sciences, Alpharetta, GA) or sham control. PATIENTS AND METHODS: Fundus photographs were assessed to determine clinically significant changes in glaucomatous indicators. RESULTS: The mean cup-to-disc ratio (CDR) change was similar with all three treatments. Compared with sham control, a significantly greater proportion of patients treated with 0.5 ?g/day but not 0.2 ?g/day FAc experienced a CDR increase of greater than 0.1. There was no significant increase in the proportion of patients experiencing a CDR increase of greater than 0.2 with either dose of implant versus sham control. Other indicators of glaucomatous change did not differ significantly with treatment. Subgroup analyses showed no differences in cupping based on ocular or baseline characteristics. CONCLUSION: Treatment with FAc for 36 months was not associated with significant glaucomatous optic nerve head changes in patients with DME with or without increased intraocular pressure

    Pilot Study of the Delivery of Microcollimated Pars Plana External Beam Radiation in Porcine Eyes: 270-Day Analysis

    Get PDF
    Objective. To determine the dose response and toxicity threshold of micro-collimated X-rays delivered to porcine maculae by a stereotactic radiosurgical system after 270 days. Methods. Twelve eyes of six Yucatan mini-swine were randomized to receive up to 90 Gy to the retina, using an office-based trans-pars plana delivery system. To determine the safety profile of this radiation delivery, ophthalmic examination, fundus photography, fluorescein angiography (FA), and spectral domain optical coherence tomography (SD-OCT) were obtained at multiple time points up to 270 days post treatment. Results. No abnormalities were noted on external examination. Cataracts were noted in 4 of 12 eyes. Dose and time-dependent changes were noted on fundus examination, FA, ICG and SD-OCT. No significant abnormalities were seen in the control, 16 Gy or 24 Gy groups using any modality. Histopathology revealed a dose response effect with no discernable lesions in the 16 Gy group. Conclusion. The X-ray delivery system precisely targets the porcine retina in vivo with little effect on surrounding structures. No ophthalmic or intracranial adverse effects were noted at clinically relevant doses at 270 days following radiation delivery

    Infektionsbiomarker im Klinikalltag - CRP, PCT & Co

    No full text
    • 

    corecore