111 research outputs found

    Integration of design tools and knowledge capture into a CAD system: a case study

    Get PDF
    onceptual design phase is partially supported by product lifecycle management/computer-aided design (PLM/CAD) systems causing discontinuity of the design information flow: customer needs — functional requirements — key characteristics — design parameters (DPs) — geometric DPs. Aiming to address this issue, it is proposed a knowledge-based approach is proposed to integrate quality function deployment, failure mode and effects analysis, and axiomatic design into a commercial PLM/CAD system. A case study, main subject of this article, was carried out to validate the proposed process, to evaluate, by a pilot development, how the commercial PLM/CAD modules and application programming interface could support the information flow, and based on the pilot scheme results to propose a full development framework

    The LOFAR Two Meter Sky Survey: Deep Fields, I -- Direction-dependent calibration and imaging

    Get PDF
    The Low Frequency Array (LOFAR) is an ideal instrument to conduct deep extragalactic surveys. It has a large field of view and is sensitive to large-scale and compact emission. It is, however, very challenging to synthesize thermal noise limited maps at full resolution, mainly because of the complexity of the low-frequency sky and the direction dependent effects (phased array beams and ionosphere). In this first paper of a series, we present a new calibration and imaging pipeline that aims at producing high fidelity, high dynamic range images with LOFAR High Band Antenna data, while being computationally efficient and robust against the absorption of unmodeled radio emission. We apply this calibration and imaging strategy to synthesize deep images of the Boötes and Lockman Hole fields at ∌150 MHz, totaling ∌80 and ∌100 h of integration, respectively, and reaching unprecedented noise levels at these low frequencies of .30 and .23 ”Jy beam−1 in the inner ∌3 deg2 . This approach is also being used to reduce the LOTSS-wide data for the second data release

    Sex Differences in Poststroke Cognitive Impairment : A Multicenter Study in 2343 Patients With Acute Ischemic Stroke

    Get PDF
    Funding Information: Dr Exalto is supported by Alzheimer Nederland WE.03-2019-15 and Netherlands CardioVascular Research Initiative: the Dutch Heart Foundation (CVON 2018-28 & 2012-06). The Meta-VCI Map consortium is supported by Vici Grant 918.16.616 from The Netherlands Organisation for Health Research and Development (ZonMw) to Dr Biessels. Harmonization analyses were supported by a Rudolf Magnus Young Talent Fellowship from the University Medical Center Utrecht Brain Center to Dr Biesbroek. The CASPER cohort was supported by Maastricht University, Health Foundation Limburg, and Stichting Adriana van Rinsum-Ponsen. The CROMIS-2 cohort was funded by the UK Stroke Association and the British Heart Foundation (grant number TSA BHF 2009/01). The CU-STRIDE cohort was supported by the Health and Health Services Research Fund of the Food and Health Bureau of the Government of Hong Kong (grant number 0708041), the Lui Che Woo Institute of Innovative Medicine, and Therese Pei Fong Chow Research Center for Prevention of Dementia. The GRECogVASC cohort was funded by Amiens University Hospital and by a grant from the French Ministry of Health (grant number DGOS R1/2013/144). The MSS-2 cohort is funded by the Wellcome Trust (grant number WT088134/Z/09/A to Dr Wardlaw) and the Row Fogo Charitable Trust. The PROCRAS cohort was funded via ZonMW as part of the TopZorg project in 2015 (grant number 842003011). The CODECS cohort (ongoing) is supported by a grant from Stichting Coolsingel (grant number 514). The Bundang VCI and Hallym VCI cohort groups do not wish to report any relevant funding sources. At the time of contribution, Dr Hamilton was funded by the College of Medicine and Veterinary Medicine at the University of Edinburgh and was supported by the Wellcome Trust through the Translational Neuroscience PhD program at the University of Edinburgh. Publisher Copyright: © 2023 Lippincott Williams and Wilkins. All rights reserved.Peer reviewedPublisher PD

    Baroreflex sensitivity differs among same strain Wistar rats from the same laboratory

    Get PDF
    Previous studies showed that a proportion of normotensive Sprague-Dawley rats spontaneously exhibit lower baroreflex sensitivity. However, investigations have not yet been carried out on Wistar rats. We aimed to compare baroreflex sensitivity among rats from the same strain and the same laboratory. Male Wistar normotensive rats (300–400g) were studied. Cannulas were inserted into the abdominal aortic artery through the right femoral artery to measure mean arterial pressure and heart rate. Baroreflex was calculated as the derivative of the variation of heart rate in function of the mean arterial pressure variation (ΔHR/ΔMAP) tested with a depressor dose of sodium nitroprusside (50 ”g/kg) and with a pressor dose of phenylephrine (8”g/kg) in the right femoral venous approach through an inserted cannula. We divided the rats into four groups: i) high bradycardic baroreflex, baroreflex gain less than −2 tested with phenylephrine; ii) low bradycardic baroreflex, baroreflex gain between −1 and −2 tested with phenylephrine; iii) high tachycardic baroreflex, baroreflex gain less than −3 tested with sodium nitroprusside; and iv) low tachycardic baroreflex, baroreflex gain between −1 and −3 tested with sodium nitroprusside. Approximately 71% of the rats presented a decrease in bradycardic reflex while around half showed an increase in tachycardic reflex. No significant changes in basal mean arterial pressure and heart rate, tachycardic and bradycardic peak and heart rate range were observed. There was a significant change in baroreflex sensitivity among rats from the same strain and the same laboratory
    • 

    corecore