30 research outputs found
Incidence, predictors and clinical impact of permanent pacemaker insertion in women following transcatheter aortic valve implantation: insights from a prospective multinational registry
To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. Background: Data on pacemaker insertion complicating TAVR in women are scarce. Methods: The Women''s International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. Results: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85â7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30â0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9â16] days in PPI vs. 9 [7â14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adjHR 0.95, 95% CI 0.60â1.52, p = 0.84 and adjHR 1.22, 95% CI 0.83â1.79, p = 0.31, respectively). Conclusion: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes
A controlled trial of rivaroxaban after transcatheter aortic-valve replacement
Background: whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. Methods: we randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. Results: after a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). Conclusions: in patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.)
Predictors of Paravalvular Regurgitation Following Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (From the REPRISE II Trial Extended Cohort)
Paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR) is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative adaptive seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL following implantation of the Lotus transcatheter aortic valve. The REPRISE II study with Extended Cohort enrolled 250 high-surgical risk patients with severe symptomatic aortic stenosis. Aortic regurgitation was assessed by echocardiography pre-procedure, at discharge and 30 days by an independent core lab. Baseline and procedural predictors of mild or greater PVL at 30 days (or at discharge if 30-day data were not available) were determined using a multivariate regression model (N=229). Among 229 patients, 197 (86%) had no/trace PVL, 30 had mild, and 2 had moderate PVL; no patient had severe PVL. Significant predictors of mild/moderate PVL included device:annulus area ratio (odds ratio [OR]: 0.87 (95% CI: 0.83-0.92); P<0.001), LVOT calcium volume (OR:2.85;(1.44-5.63); P=0.003), and annulus area (OR:0.89(0.82-0.96); P=0.002). When the device:annulus area ratio was <1, the rate of mild/moderate PVL was 53.1% (17/32). The rates of mild/moderate PVL with 0-5%, 5-10%, and >10% annular oversizing by area were 17.5% (11/63), 2.9% (2/70), and 3.2% (2/63), respectively. Significant independent predictors of PVL included device:annulus area ratio and LVOT calcium volume. When the prosthetic valve was oversized by â„5%, the rate of mild or greater PVL was only 3%. In conclusion, the overall rates of PVL with the Lotus Valve are low and predominantly related to device/annulus areas and calcium; these findings have implications for optimal device sizing
Adjunctive Antithrombotic Therapy for Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement.
Importance: Transcatheter aortic valve replacement (TAVR) is an established alternative to surgery for patients with severe symptomatic aortic stenosis. Adjunctive antithrombotic therapy used to mitigate thrombotic risks in patients undergoing TAVR must be balanced against bleeding complications, since both are associated with increased mortality. Observation: Stroke risk associated with TAVR is lower than that associated with surgical aortic valve replacement in recent trials including patients at intermediate or low risk, but it is constant beginning at the time of implant and accrues over time based on patient risk factors. Patients with aortic stenosis undergoing TAVR also have a sizable risk of life-threatening or major bleeding. Although dual antiplatelet therapy for 3 to 6 months after TAVR is the guideline-recommended regimen, this practice is not well supported by current evidence. In patients with no indication for oral anticoagulation, current registry-based evidence suggests that single antiplatelet therapy may be safer than dual antiplatelet therapy. Similarly, oral anticoagulation monotherapy appears superior to anticoagulation plus antiplatelet therapy in those where oral anticoagulant use is indicated. To date, no risk prediction models have been established to guide antithrombotic therapy. Conclusions and Relevance: Despite the growing volume of TAVR procedures to treat patients with severe aortic stenosis, evidence for adjunctive antithrombotic therapy remains rather scarce. Ongoing clinical trials will provide better understanding to guide antithrombotic therapy
Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial
Objectives: This study sought to test the superiority in terms of efficacy and safety of a dedicated plug-based vascular closure device (VCD) during transcatheter aortic valve replacement (TAVR) over a suture-based VCD. Background: Vascular complications after TAVR are relevant and often associated with VCD failure. Methods: The MASH (MANTA vs. Suture-based vascular closure after transcatHeter aortic valve replacement) trial is an international, 2-center pilot randomized controlled trial comparing the MANTA VCD (Teleflex, Wayne, Pennsylvania) versus 2 ProGlides (Abbott Vascular, Abbott Park, Illinois). The primary composite endpoint consisted of access siteârelated major or minor vascular complications at 30-daysâ follow-up. Secondary endpoints included clinically relevant access site bleeding, time to hemostasis, and modified VCD failure (defined as failure to achieve hemostasis within 5 min or requiring additional endovascular maneuvers such as endovascular stenting, surgical techniques, or additional closure devices). Adverse events were adjudicated by an independent clinical events committee according to the VARC-2 definitions. Results: A total of 210 TAVR patients were included between October 2018 and January 2020. Median age was 81 years, 54% were male, and the median STS score was 2.7%. There was no significant difference in the primary endpoint of access siteârelated vascular complications between MANTA and ProGlide (10% vs. 4%; p = 0.16). Clinically significant access site bleedings were similar with both closure techniques (9% vs. 6%; p = 0.57). Modified VCD failure occurred less frequently in MANTA versus ProGlide (20% vs. 40%; p < 0.01). Suture-based closure required more often additional closure devices, whereas MANTA numerically needed more covered stents and surgical bailouts. Conclusions: Plug-based large-bore arteriotomy closure was not superior to suture-based closure. Plug-based closure required fewer, but a different kind of bailout maneuvers
GuĂa ESC/EACTS 2017 sobre el tratamiento de las valvulopatĂas
[No abstract available
Mitral valve-in-valve and valve-in-ring procedures: Midterm outcomes in a French nationwide registry
International audienceOBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; nâ=â89) or valve-in-ring (ViR; nâ=â13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; pâ=â0.004) and more frequently severe regurgitation (46% vs. 15%; pâ=â0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (pâ=â0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA classââ€âII (vs. 25% at baseline; pâ\textlessâ0.001). At a mean follow-up of 17.1â±â11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; pâ=â0.031) while ViR was not found statistically associated (pâ=â0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes