160 research outputs found

    TIRSPEC : TIFR Near Infrared Spectrometer and Imager

    Full text link
    We describe the TIFR Near Infrared Spectrometer and Imager (TIRSPEC) designed and built in collaboration with M/s. Mauna Kea Infrared LLC, Hawaii, USA, now in operation on the side port of the 2-m Himalayan Chandra Telescope (HCT), Hanle (Ladakh), India at an altitude of 4500 meters above mean sea level. The TIRSPEC provides for various modes of operation which include photometry with broad and narrow band filters, spectrometry in single order mode with long slits of 300" length and different widths, with order sorter filters in the Y, J, H and K bands and a grism as the dispersing element as well as a cross dispersed mode to give a coverage of 1.0 to 2.5 microns at a resolving power R of ~1200. The TIRSPEC uses a Teledyne 1024 x 1024 pixel Hawaii-1 PACE array detector with a cutoff wavelength of 2.5 microns and on HCT, provides a field of view of 307" x 307" with a plate scale of 0.3"/pixel. The TIRSPEC was successfully commissioned in June 2013 and the subsequent characterization and astronomical observations are presented here. The TIRSPEC has been made available to the worldwide astronomical community for science observations from May 2014.Comment: 20 pages, 21 figures, 2 tables. Accepted for publication in Journal of Astronomical Instrumentatio

    SYNTHESIS, AB INITIO STRUCTURE DETERMINATION, AND CHARACTERIZATION OF MANGANESE(III) PHENYL PHOSPHONATES

    Get PDF
    ABSTRACT , space group P1, and Z ϭ 2. The final agreement factors were R WP ϭ 12.8%, R P ϭ 9.1%, and R F ϭ 3.2%. There are 22 non-hydrogen atoms in the asymmetric part of the unit cell, and the positional parameters were refined with the help of soft constraints. The octahedral manganese coordination spheres are distorted due to the Jahn-Teller effect. The structure of this organic-inorganic compound is layered. The thermal behavior of Mn(HO 3 PC 6 H 5 )(O 3 PC 6 H 5 )⅐H 2 O was studied and its thermal decomposition product was identified. © 1998 Elsevier Science Lt

    Divalent Metal Vinylphosphonate Layered Materials: Compositional Variability, Structural Peculiarities, Dehydration Behavior, and Photoluminescent Properties

    Get PDF
    A family of M-VP (M = Ni, Co, Cd, Mn, Zn, Fe, Cu, Pb; VP = vinylphosphonate) and M-PVP (M = Co, Cd; PVP = phenylvinylphosphonate) materials have been synthesized by hydrothermal methods and characterized by FTIR, elemental analysis, and thermogravimetric analysis (TGA). Their structures were determined either by single crystal X-ray crystallography or from laboratory X-ray powder diffraction data. The crystal structure of some M-VP and M-PVP materials is two-dimensional (2D) layered, with the organic groups (vinyl or phenylvinyl) protruding into the interlamellar space. However, the Pb-VP and Cu-VP materials show dramatically different structural features. The porous, three-dimensional (3D) structure of Pb-VP contains the Pb center in a pentagonal pyramid. A Cu-VP variant of the common 2D layered structure shows a very peculiar structure. The structure of the material is 2D with the layers based upon three crystallographically distinct Cu atoms; an octahedrally coordinated Cu2+ atom, a square planar Cu2+ atom and a Cu+ atom. The latter has an unusual co-ordination environment as it is 3-coordinated to two oxygen atoms with the third bond across the double bond of the vinyl group. Metal-coordinated water loss was studied by TGA and thermodiffractometry. The rehydration of the anhydrous phases to give the initial phase takes place rapidly for Cd-PVP but it takes several days for Co-PVP. The M-VP materials exhibit variable dehydration-rehydration behavior, with most of them losing crystallinity during the process.Proyecto nacional MAT2010-15175 (MICINN, España

    Antimicrobial consumption and resistance in adult hospital inpatients in 53 countries:results of an internet-based global point prevalence survey

    Get PDF
    Summary: Background: The Global Point Prevalence Survey (Global-PPS) established an international network of hospitals to measure antimicrobial prescribing and resistance worldwide. We aimed to assess antimicrobial prescribing and resistance in hospital inpatients. Methods: We used a standardised surveillance method to collect detailed data about antimicrobial prescribing and resistance from hospitals worldwide, which were grouped by UN region. The internet-based survey included all inpatients (adults, children, and neonates) receiving an antimicrobial who were on the ward at 0800 h on one specific day between January and September, 2015. Hospitals were classified as primary, secondary, tertiary (including infectious diseases hospitals), and paediatric hospitals. Five main ward types were defined: medical wards, surgical wards, intensive-care units, haematology oncology wards, and medical transplantation (bone marrow or solid transplants) wards. Data recorded included patient characteristics, antimicrobials received, diagnosis, therapeutic indication according to predefined lists, and markers of prescribing quality (eg, whether a stop or review date were recorded, and whether local prescribing guidelines existed and were adhered to). We report findings for adult inpatients. Findings: The Global-PPS for 2015 included adult data from 303 hospitals in 53 countries, including eight lower-middle-income and 17 upper-middle-income countries. 86 776 inpatients were admitted to 3315 adult wards, of whom 29 891 (34·4%) received at least one antimicrobial. 41 213 antimicrobial prescriptions were issued, of which 36 792 (89·3%) were antibacterial agents for systemic use. The top three antibiotics prescribed worldwide were penicillins with β-lactamase inhibitors, third-generation cephalosporins, and fluoroquinolones. Carbapenems were most frequently prescribed in Latin America and west and central Asia. Of patients who received at least one antimicrobial, 5926 (19·8%) received a targeted antibacterial treatment for systemic use, and 1769 (5·9%) received a treatment targeting at least one multidrug-resistant organism. The frequency of health-care-associated infections was highest in Latin America (1518 [11·9%]) and east and south Asia (5363 [10·1%]). Overall, the reason for treatment was recorded in 31 694 (76·9%) of antimicrobial prescriptions, and a stop or review date in 15 778 (38·3%). Local antibiotic guidelines were missing for 7050 (19·2%) of the 36 792 antibiotic prescriptions, and guideline compliance was 77·4%. Interpretation: The Global-PPS showed that worldwide surveillance can be accomplished with voluntary participation. It provided quantifiable measures to assess and compare the quantity and quality of antibiotic prescribing and resistance in hospital patients worldwide. These data will help to improve the quality of antibiotic prescribing through education and practice changes, particularly in low-income and middle-income countries that have no tools to monitor antibiotic prescribing in hospitals. Funding: bioMérieux

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved
    corecore