336 research outputs found

    Near-critical point phenomena in fluids (19-IML-1)

    Get PDF
    Understanding the effects of gravity is essential if the behavior of fluids is to be predicted in spacecraft and orbital stations, and, more generally, to give a better understanding of the hydrodynamics in these systems. An understanding is sought of the behavior of fluids in space. What should emerge from the International Microgravity Lab (IML-1) mission is a better understanding of the kinetics of growth in off-critical conditions, in both liquid mixtures and pure fluids. This complex phenomenon is the object of intensive study in physics and materials sciences area. It is also expected that the IML-1 flight will procure key results to provide a better understanding of how a pure fluid can be homogenized without gravity induced convections, and to what extent the 'Piston Effect' is effective in thermalizing the compressible fluids

    Is CHF triggered by the vapor recoil effect?

    Get PDF
    This paper deals with the triggering mechanism of the boiling crisis, a transition from nucleate to film boiling. We observe the boiling crisis in pool saturated boiling experimentally at nearly critical pressure to take advantage of the slowness of the bubble growth and of the smallness of the Critical Heat Flux (CHF) that defines the transition point. Such experiments require the reduced gravity conditions. Close to the CHF, the slow growth of the individual dry spots and their subsequent fusion on the transparent heater are observed through the latter. As discussed in the paper, these observations are consistent with numerical results obtained with the vapor recoil model of the boiling crisis

    Quench cooling under reduced gravity

    Full text link
    We report the quench cooling experiments performed with liquid O2 under different levels of gravity simulated with the magnetic gravity compensation. A copper disk is quenched from 270K to 90K. It is found that the cooling time in microgravity is very long in comparison with any other gravity level. This phenomenon is explained by the isolation effect of the gas surrounding the disk. The liquid subcooling is shown to drastically improuve the heat exchange thus reducing the cooling time (about 20 times). The effect of subcooling on the heat transfer is analyzed at different gravity levels. It is shown that such type of experiments cannot be used for the analysis of the critical heat flux (CHF) of the boiling crisis. The minimum heat flux (MHF) of boiling is analyzed instead

    Radiation-cooled Dew Water Condensers Studied by Computational Fluid Dynamic (CFD)

    Get PDF
    Harvesting condensed atmospheric vapour as dew water can be an alternative or complementary potable water resource in specific arid or insular areas. Such radiation-cooled condensing devices use already existing flat surfaces (roofs) or innovative structures with more complex shapes to enhance the dew yield. The Computational Fluid Dynamic - CFD - software PHOENICS has been programmed and applied to such radiation cooled condensers. For this purpose, the sky radiation is previously integrated and averaged for each structure. The radiative balance is then included in the CFD simulation tool to compare the efficiency of the different structures under various meteorological parameters, for complex or simple shapes and at various scales. It has been used to precise different structures before construction. (1) a 7.32 m^2 funnel shape was studied; a 30 degree tilted angle (60 degree cone half-angle) was computed to be the best compromise for funnel cooling. Compared to a 1 m^2 flat condenser, the cooling efficiency was expected to be improved by 40%. Seventeen months measurements in outdoor tests presented a 138 % increased dew yield as compared to the 1 m^2 flat condenser. (2) The simulation results for 5 various condenser shapes were also compared with experimental measurement on corresponding pilots systems: 0.16 m^2 flat planar condenser, 1 m^2 and 30 degree tilted planar condenser, 30 m^2 and 30 degree tilted planar condenser, 255 m^2 multi ridges, a preliminary construction of a large scale dew plant being implemented in the Kutch area (Gujarat, India)

    Dew frequency across the US from a network of in situ radiometers

    Get PDF
    Dew formation is a ubiquitous process, but its importance to energy budgets or ecosystem health is difficult to constrain. This uncertainty arises largely because of a lack of continuous quantitative measurements on dew across ecosystems with varying climate states and surface characteristics. This study analyzes dew frequency from the National Ecological Observatory Network (NEON), which includes 11 grasslands and 19 forest sites from 2015 to 2017. Dew formation is determined at 30&thinsp;min intervals using in situ radiometric surface temperatures from multiple heights within the canopy along with meteorological measurements. Dew frequency in the grasslands ranges from 15 % to 95 % of the nights with a strong linear dependency on the nighttime relative humidity (RH), while dew frequency in the forests is less frequent and more homogeneous (25±14 %, 1 standard deviation – SD). Dew mostly forms at the top of the canopy for the grasslands due to more effective radiative cooling and within the canopy for the forests because of higher within the canopy RH. The high temporal resolution of our data showed that dew duration reaches maximum values (∼6–15&thinsp;h) for RH∼96 % and for a wind speed of ∼0.5ms-1, independent of the ecosystem type. While dew duration can be inferred from the observations, dew yield needs to be estimated based on the Monin–Obukhov similarity theory. We find yields of 0.14±0.12mmnight-1 (1 SD from nine grasslands) similar to previous studies, and dew yield and duration are related by a quadratic relationship. The latent heat flux released by dew formation is estimated to be non-negligible (∼10Wm-2), associated with a Bowen ratio of ∼3. The radiometers used here provide canopy-averaged surface temperatures, which may underestimate dew frequency because of localized cold points in the canopy that fall below the dew point. A statistical model is used to test this effect and shows that dew frequency can increase by an additional ∼5 % for both ecosystems by considering a reasonable distribution around the mean canopy temperature. The mean dew duration is almost unaffected by this sensitivity analysis. In situ radiometric surface temperatures provide a continuous, non-invasive and robust tool for studying dew frequency and duration on a fine temporal scale.</p

    Study of fluid behaviour under gravity compensated by a magnetic field

    Get PDF
    International audienceFluids, and especially cryogenic fluids like Hydrogen H2 and Oxygen O2 , are widely used in space technology for propulsion and cooling. The knowledge of fluid behaviour during the acceleration variation and under reduced gravity is necessary for an efficient management of fluids in space. Such a management also asks fundamental questions about thermo-hydrodynamics and phase change once buoyancy forces are cancelled. For security reasons, it is nearly impossible to use the classical microgravity means to experiment with such cryofluids. However, it is possible to counterbalance gravity by using the paramagnetic (O2) or diamagnetic (H2) properties of fluids. By applying a magnetic field gradient on these materials, a volume force is created that is able to impose to the fluid a varying effective gravity, including microgravity. We have set up a magnetic levitation facility for H2 in which many experiments have been performed. A new facility for O2 is under construction that will enable fast change in the effective gravity by quenching down the magnetic field. The facilities and some particularly representative experimental results are presented

    Fast heat transfer calculations in supercritical fluids versus hydrodynamic approach

    Get PDF
    International audienceThis study investigates the heat transfer in a simple pure fluid whose temperature is slightly above its critical temperature. We propose a efficient numerical method to predict the heat transfer in such fluids when the gravity can be neglected. The method, based on a simplified thermodynamic approach, is compared with direct numerical simulations of the Navier-Stokes and energy equations performed for CO2 and SF6. A realistic equation of state is used to describe both fluids. The proposed method agrees with the full hydrodynamic solution and provides a huge gain in computation time. The connection between the purely thermodynamic and hydrodynamic descriptions is also discussed

    A Study of Dew Water Yields on Galvanized Iron Roof in Kothara (North-West India)

    Get PDF
    In order to determine what amount of dew water can be collected without much investment during the dry season (October –May) in north - west India, a study was performed on plain, un-insulated, corrugated galvanized iron roofs that are common in this rural region. Between October 1, 2004 and May 31, 2005, the cumulative dew yield on a 18 m2 double - sloped (30�) test roof was 113.5 L. The west side gave 35 % higher water yield than the east side. The use of thermal insulation and more IR radiative materials would have increased this yield by 40 % (160 L). An analysis of dew events is made with meteorological data. It shows that the variable relative humidity is the most important parameter, which in turn is strongly correlated with the average wind direction with respect to monsoon direction. The cumulative dew water yield (6.3 mm) remains modest when compared with the average rain fall (300 mm). But dew occurs far more frequently than rain and it forms precisely during the dry season when water is most scarce.
    corecore