320 research outputs found

    Factors involved in the handling of iron by the reticulo-endothelial system

    Get PDF
    A thesis presented for the degree of Doctor of Philosophy in Medicine of the University of the Witwatersrand, Johannesburg 1972For centuries iron was regarded as a source of health and vigour, and it has been known for at least 200 years that it is a component of blood and effective in the treatment of chlorosis. However, its metabolism remained largely a mystery until the advent of radioactive iron isotopes in 1938. Since then most of the major pathways of this metal into, through and out of the body have been elucidated. In addition the functions which it subserves have been partially characterized.IT201

    A predictive phenomenological tool at small Bjorken-x

    Full text link
    We present the results from global fits of inclusive DIS experimental data using the Balitsky-Kovchegov equation with running coupling.Comment: 5 pages, 2 figures, prepared for the Proceedings of 'Hot Quarks 2010

    Two-body quantum mechanical problem on spheres

    Full text link
    The quantum mechanical two-body problem with a central interaction on the sphere Sn{\bf S}^{n} is considered. Using recent results in representation theory an ordinary differential equation for some energy levels is found. For several interactive potentials these energy levels are calculated in explicit form.Comment: 41 pages, no figures, typos corrected; appendix D was adde

    Iron bioavailability in two commercial cultivars of wheat: a comparison between wholegrain and white flour and the effects of nicotianamine and 2'-deoxymugineic acid on iron uptake into Caco-2 cells

    Get PDF
    Iron bioavailability in unleavened white and wholegrain bread made from two commercial wheat varieties was assessed by measuring ferritin production in Caco-2 cells. The breads were subjected to simulated gastrointestinal digestion and the digests applied to the Caco-2 cells. Although Riband grain contained a lower iron concentration than Rialto, iron bioavailability was higher. No iron was taken up by the cells from white bread made from Rialto flour or from wholegrain bread from either variety, but Riband white bread produced a small ferritin response. The results probably relate to differences in phytate content of the breads, although iron in soluble monoferric phytate was demonstrated to be bioavailable in the cell model. Nicotianamine, an iron chelator in plants involved in iron transport, was a more potent enhancer of iron uptake into Caco-2 cells than ascorbic acid or 2'-deoxymugineic acid, another metal chelator present in plants

    Adjusting plasma ferritin concentrations to remove the effects of subclinical inflammation in the assessment of iron deficiency: a meta-analysis

    Get PDF
    Background: The World Health Organization recommends serum ferritin concentrations as the best indicator of iron deficiency (ID). Unfortunately, ferritin increases with infections; hence, the prevalence of ID is underestimated. Objective: The objective was to estimate the increase in ferritin in 32 studies of apparently healthy persons by using 2 acute-phase proteins (APPs). C-reactive protein (CRP) and alpha(1)-acid glycoprotein (AGP), individually and in combination, and to calculate factors to remove the influence of inflammation from ferritin concentrations. Design: We estimated the increase in ferritin associated with inflammation (ie, CRP >5 mg/L and/or AGP >1 g/L). The 32 studies comprised infants (5 studies), children (7 studies), men (4 studies), and women (16 studies) (n = 8796 subjects). In 2-group analyses (either CRP or AGP), we compared the ratios of log ferritin with or without inflammation in 30 studies. In addition, in 22 studies, the data allowed a comparison of ratios of log ferritin between 4 subgroups: reference (no elevated APP), incubation (elevated CRP only), early convalescence (both APP and CRP elevated), and late convalescence (elevated AGP only). Results: In the 2-group analysis, inflammation increased ferritin by 49.6% (CRP) or 38.2% (AGP; both P <0.001). Elevated AGP was more common than CRP in young persons than in adults. In the 4-group analysis, ferritin was 30%, 90%, and 36% (all P < 0.001) higher in the incubation, early convalescence, and late convalescence subgroups, respectively, with corresponding correction factors of 0.77, 0.53, and 0.75. Overall, inflammation increased ferritin by approximate to 30% and was associated with a 14% (CI: 7%, 21%) underestimation of ID. Conclusions: Measures of both APP and CRP are needed to estimate the full effect of inflammation and can be used to correct ferritin concentrations. Few differences were observed between age and sex subgroups. Am J Clin Nutr 2010;92:546-55

    Effect of haemoglobin concentration on the clinical outcomes in patients with acute myocardial infarction and the factors related to haemoglobin

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The impact of haemoglobin concentrations on clinical outcomes is still a controversial issue. To determine the association between haemoglobin concentrations on admission and clinical outcomes and the related factors, this study was performed in a Chinese hospital.</p> <p>Findings</p> <p>We conducted a retrospective study on 1394 Chinese patients with acute myocardial infarction. Patients were categorized according to the haemoglobin concentration on admission, and data were evaluated to determine whether there was an association between the haemoglobin concentrations on admission and 30-day in-hospital MACEs (major cardiovascular events). Patients with hemoglobin values between 141 and 150 g/L were used as the reference, the MACEs increased as hemoglobin concentrations fell below 140 g/L or rose > 150 g/L, with an adjusted OR (odds ratio) of 5.96[95% CI (confidence interval) 2.00 to 17.68, p = 0.0013], 4.39(1.37 to 14.08, p = 0.0128), 3.99(1.46 to 10.92, p = 0.0071), 3.19(1.27 to 8.05, p = 0.0139), 2.37(0.94 to 6.01, p = 0.0687), 2.11(0.66 to 6.74, p = 0.2065), 2.01(0.60 to 6.68, p = 0.2559) in patients with haemoglobin concentrations <100 g/L, 101-110 g/L, 111-120 g/L, 121-130 g/L, 131-140 g/L, 151-160 g/L, and >160 g/L respectively. Partial correlation analysis showed that age, albumin and creatinine were significantly associated with hemoglobin concentration.</p> <p>Conclusions</p> <p>Our results demonstrated that haemoglobin concentration affected MACEs in patients with acute myocardial infarction, and that haemoglobin concentration was associated with age, albumin and creatinine.</p

    UV activation of polymeric high aspect ratio microstructures: Ramifications in antibody surface loading for circulating tumor cell selection

    Get PDF
    The need to activate thermoplastic surfaces using robust and efficient methods has been driven by the fact that replication techniques can be used to produce microfluidic devices in a high production mode and at low cost, making polymer microfluidics invaluable for in vitro diagnostics, such as circulating tumor cell (CTC) analysis, where device disposability is critical to mitigate artifacts associated with sample carryover. Modifying the surface chemistry of thermoplastic devices through activation techniques can be used to increase the wettability of the surface or to produce functional scaffolds to allow for the covalent attachment of biologics, such as antibodies for CTC recognition. Extensive surface characterization tools were used to investigate UV activation of various surfaces to produce uniform and high surface coverage of functional groups, such as carboxylic acids in microchannels of different aspect ratios. We found that the efficiency of the UV activation process is highly dependent on the microchannel aspect ratio and the identity of the thermoplastic substrate. Colorimetric assays and fluorescence imaging of UV-activated microchannels following EDC/NHS coupling of Cy3-labeled oligonucleotides indicated that UV-activation of a PMMA microchannel with an aspect ratio of ???3 was significantly less efficient toward the bottom of the channel compared to the upper sections. This effect was a consequence of the bulk polymer&apos;s damping of the modifying UV radiation due to absorption artifacts. In contrast, this effect was less pronounced for COC. Moreover, we observed that after thermal fusion bonding of the device&apos;s cover plate to the substrate, many of the generated functional groups buried into the bulk rendering them inaccessible. The propensity of this surface reorganization was found to be higher for PMMA compared to COC. As an example of the effects of material and microchannel aspect ratios on device functionality, thermoplastic devices for the selection of CTCs from whole blood were evaluated, which required the immobilization of monoclonal antibodies to channel walls. From our results, we concluded the CTC yield and purity of isolated CTCs were dependent on the substrate material with COC producing the highest clinical yields for CTCs as well as better purities compared to PMMA.close9
    corecore