49 research outputs found

    Absorption cross section in Lifshitz black hole

    Full text link
    We derive the absorption cross section of a minimally coupled scalar in the Lifshitz black hole obtained from the new massive gravity. The absorption cross section reduces to the horizon area in the low energy and massless limit of s-wave mode propagation, indicating that the Lifshitz black hole also satisfies the universality of low energy absorption cross section for black holes.Comment: 13 pages, 1 figure, version to appear in EPJ

    LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients

    Get PDF
    Background: Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP (R)) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Methods: Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 degrees C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP (R) MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. Results: The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/mu l. Conclusions: The Pan primer of the Malaria kit LoopAMP (R) can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.Peer reviewe

    From Nuevo LeĂłn to the USA and Back Again: Transnational Students in Mexico

    Get PDF
    The movement of Mexicans to the United States is both longstanding and long studied and from that study we know that for many newcomers the attachment to the receiving community is fraught and tentative. The experience of immigrant children in U.S. schools is also relatively well studied and reveals challenges of intercultural communication as well as concurrent and contradictory features of welcome and unwelcome. What is less well known, in the study of migration generally and of transnational students in particular, is how students moving in a less common direction — from the U.S. to Mexico — experience that movement. Based on visits to 173 randomly selected classrooms in the state of Nuevo León Mexico, this study shares survey and interview data from 208 of the 242 students encountered who had previous experience attending school in the United States

    Neurocognition and quality of life after reinitiating antiretroviral therapy in children randomized to planned treatment interruption

    Get PDF
    Objective: Understanding the effects of antiretroviral treatment (ART) interruption on neurocognition and quality of life (QoL) are important for managing unplanned interruptions and planned interruptions in HIV cure research. Design: Children previously randomized to continuous (continuous ART, n=41) vs. planned treatment interruption (PTI, n=47) in the Pediatric European Network for Treatment of AIDS (PENTA) 11 study were enrolled. At study end, PTI children resumed ART. At 1 and 2 years following study end, children were assessed by the coding, symbol search and digit span subtests of Wechsler Intelligence Scale for Children (6-16 years old) or Wechsler Adult Intelligence Scale ( 6517 years old) and by Pediatrics QoL questionnaires for physical and psychological QoL. Transformed scaled scores for neurocognition and mean standardized scores for QoL were compared between arms by t-test and Mann-Whitney U test, respectively. Scores indicating clinical concern were compared (<7 for neurocognition and <70 for QoL tests). Results: Characteristics were similar between arms with a median age of 12.6 years, CD4 + of 830 cells/\u3bcl and HIV RNA of 1.7 log 10 copies/ml. The median cumulative ART exposure was 9.6 in continuous ART vs. 7.7 years in PTI (P=0.02). PTI children had a median of 12 months off ART and had resumed ART for 25.2 months at time of first assessment. Neurocognitive scores were similar between arms for all tests. Physical and psychological QoL scores were no different. About 40% had low neurocognitive and QoL scores indicating clinical concern. Conclusion: No differences in information processing speed, sustained attention, short-term memory and QoL functioning were observed between children previously randomized to continuous ART vs. PTI in the PENTA 11 trial

    Autoantibodies against type I IFNs in patients with life-threatening COVID-19

    Get PDF
    Interindividual clinical variability in the course of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is vast. We report that at least 101 of 987 patients with life-threatening coronavirus disease 2019 (COVID-19) pneumonia had neutralizing immunoglobulin G (IgG) autoantibodies (auto-Abs) against interferon-w (IFN-w) (13 patients), against the 13 types of IFN-a (36), or against both (52) at the onset of critical disease; a few also had auto-Abs against the other three type I IFNs. The auto-Abs neutralize the ability of the corresponding type I IFNs to block SARS-CoV-2 infection in vitro. These auto-Abs were not found in 663 individuals with asymptomatic or mild SARS-CoV-2 infection and were present in only 4 of 1227 healthy individuals. Patients with auto-Abs were aged 25 to 87 years and 95 of the 101 were men. A B cell autoimmune phenocopy of inborn errors of type I IFN immunity accounts for life-threatening COVID-19 pneumonia in at least 2.6% of women and 12.5% of men
    corecore