43 research outputs found

    A parallel algorithm for solving the incompressible Navier-Stokes problems

    Get PDF
    AbstractWe introduce and analyze a parallel algorithm for solving the Navier-Stokes equations based on the splitting of the two main difficulties involved, the presence of nonlinear terms and the zero divergence condition. The numerical results obtained by using the proposed algorithm are quite consistent with those furnished by other known algorithms. Numerical results are discussed, as well as the advantages of this new algorithm

    Comparative genomic hybridization and amplotyping by arbitrarily primed PCR in stage A B-CLL

    Get PDF
    Cytogenetic analysis is useful in the diagnosis and to assess prognosis of B-cell chronic lymphocytic leukemia (B-CLL). However, successful cytogenetics by standard techniques has been hindered by the low in vitro mitotic activity of the malignant B-cell population. Fluorescence in situ hybridization (FISH) has become a useful tool, but it does not provide an overall view of the aberrations. To overcome this hurdle, two DNA-based techniques have been tested in the present study: comparative genomic hybridization (CGH) and amplotyping by arbitrarily primed PCR (AP-PCR). Comparative genomic hybridization resolution depends upon the 400-bands of the human standard karyotype. AP-PCR allows detection of allelic losses and gains in tumor cells by PCR fingerprinting, thus its resolution is at the molecular level. Both techniques were performed in 23 patients with stage A B-CLL at diagnosis. The results were compared with FISH. The sensitivity of AP-PCR was greater than CGH (62% vs. 43%). The use of CGH combined with AP-PCR allowed to detect genetic abnormalities in 79% (15/19) of patients in whom G-banding was not informative, providing a global view of the aberrations in a sole experiment. This study shows that combining these two methods with FISH, makes possible a more precise genetic characterization of patients with B-CLL

    Severe Asthma Standard-of-Care Background Medication Reduction With Benralizumab: ANDHI in Practice Substudy

    Full text link
    peer reviewedBackground: The phase IIIb, randomized, parallel-group, placebo-controlled ANDHI double-blind (DB) study extended understanding of the efficacy of benralizumab for patients with severe eosinophilic asthma. Patients from ANDHI DB could join the 56-week ANDHI in Practice (IP) single-arm, open-label extension substudy. Objective: Assess potential for standard-of-care background medication reductions while maintaining asthma control with benralizumab. Methods: Following ANDHI DB completion, eligible adults were enrolled in ANDHI IP. After an 8-week run-in with benralizumab, there were 5 visits to potentially reduce background asthma medications for patients achieving and maintaining protocol-defined asthma control with benralizumab. Main outcome measures for non–oral corticosteroid (OCS)-dependent patients were the proportions with at least 1 background medication reduction (ie, lower inhaled corticosteroid dose, background medication discontinuation) and the number of adapted Global Initiative for Asthma (GINA) step reductions at end of treatment (EOT). Main outcomes for OCS-dependent patients were reductions in daily OCS dosage and proportion achieving OCS dosage of 5 mg or lower at EOT. Results: For non–OCS-dependent patients, 53.3% (n = 208 of 390) achieved at least 1 background medication reduction, increasing to 72.6% (n = 130 of 179) for patients who maintained protocol-defined asthma control at EOT. A total of 41.9% (n = 163 of 389) achieved at least 1 adapted GINA step reduction, increasing to 61.8% (n = 110 of 178) for patients with protocol-defined EOT asthma control. At ANDHI IP baseline, OCS dosages were 5 mg or lower for 40.4% (n = 40 of 99) of OCS-dependent patients. Of OCS-dependent patients, 50.5% (n = 50 of 99) eliminated OCS and 74.7% (n = 74 of 99) achieved dosages of 5 mg or lower at EOT. Conclusions: These findings demonstrate benralizumab's ability to improve asthma control, thereby allowing background medication reduction. © 202

    Elliptic flow of charged particles at midrapidity relative to the spectator plane in Pb–Pb and Xe–Xe collisions

    Get PDF
    Measurements of the elliptic flow coefficient relative to the collision plane defined by the spectator neutrons v2{ SP} in collisions of Pb ions at center-of-mass energy per nucleon–nucleon pair √ 2.76 TeV and Xe ions at √ sNN = sNN =5.44 TeV are reported. The results are presented for charged particles produced at midrapidity as a function of centrality and transverse momentum for the 5–70% and 0.2–6 GeV/c ranges, respectively. The ratio between v2{ SP} and the elliptic flow coefficient relative to the participant plane v2{4}, estimated using four-particle correlations, deviates by up to 20% from unity depending on centrality. This observation differs strongly from the magnitude of the corresponding eccentricity ratios predicted by the TRENTo and the elliptic power models of initial state fluctuations that are tuned to describe the participant plane anisotropies. The differences can be interpreted as a decorrelation of the neutron spectator plane and the reaction plane because of fragmentation of the remnants from the colliding nuclei, which points to an incompleteness of current models describing the initial state fluctuations. A significant transverse momentum dependence of the ratio v2{ SP}/v2{4} is observed in all but the most central collisions, which may help to understand whether momentum anisotropies at low and intermediate transverse momentum have a common origin in initial state f luctuations. The ratios of v2{ SP} and v2{4} to the corresponding initial state eccentricities for Xe–Xe and Pb–Pb collisions at similar initial entropy density show a difference of (7.0 ±0.9)%with an additional variation of +1.8% when including RHIC data in the TRENTo parameter extraction. These observations provide new experimental constraints for viscous effects in the hydrodynamic modeling of the expanding quark–gluon plasma produced in heavy-ion collisions at the LHC

    8. Escuela hispano-francesa sobre simulacion numerica en fisica e ingenieria Resumenes de los cursos

    No full text
    Centro de Informacion y Documentacion Cientifica (CINDOC). C/Joaquin Costa, 22. 28002 Madrid. SPAIN / CINDOC - Centro de InformaciĂČn y DocumentaciĂČn CientĂŹficaSIGLEESSpai

    Removal of Cu(II) ions from aqueous streams using poly(acrylic acid-co-acrylamide) hydrogels

    No full text
    The adsorption of Cu(II) ions from aqueous solutions onto poly(acrylic acid-co-acrylamide) hydrogels was investigated. The hydrogels were prepared via free-radical solution polymerization using Irgacure 754 as a photoinitiator and ethylene glycol dimethacrylate as a cross-linking agent. Loading of acrylamide/acrylic acid moieties on the surfaces of hydrogels and the amount of cross-linking agent were varied to determine the maximum metal uptake. Polymerization kinetics was investigated by 1H NMR. The physicochemical properties of hydrogels were investigated by nitrogen sorption measurements, elemental analysis, Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS). The 1H NMR results demonstrated that the polymerization reaction was carried out almost to completion and confirmed the absence of residual monomers. Swelling results indicated that, by appropriate selection of cross-linking agent amount and monomer ratio, hydrogels can be swollen up to 70,000%. Further characterization of the hydrogels showed rapid adsorption kinetics and equilibrium Cu(II) adsorption capacities of 121mgg-1. Cu(II) adsorption kinetic data followed pseudo-first-order kinetics. Adsorption equilibrium data were better fitted by a Langmuir isotherm. FTIR and XPS results indicated the presence of a tetradentate copper complex on the surfaces of hydrogels. The copper uptake achieved suggests the potential use of hydrogels to extract toxic metals from industrial aqueous streams. © 2010 Elsevier Inc
    corecore