2,661 research outputs found

    Low-pressure, chemical vapor deposition polysilicon

    Get PDF
    The low-pressure chemical vapor deposition (LPCVD) of polycrystalline silicon was investigted. The physical system was described, as was the controlling process parameters and requirements for producing films for use as an integral portion of the solar cell contact system

    Equilibrium Distribution of Mutators in the Single Fitness Peak Model

    Get PDF
    This paper develops an analytically tractable model for determining the equilibrium distribution of mismatch repair deficient strains in unicellular populations. The approach is based on the single fitness peak (SFP) model, which has been used in Eigen's quasispecies equations in order to understand various aspects of evolutionary dynamics. As with the quasispecies model, our model for mutator-nonmutator equilibrium undergoes a phase transition in the limit of infinite sequence length. This "repair catastrophe" occurs at a critical repair error probability of ϵr=Lvia/L \epsilon_r = L_{via}/L , where Lvia L_{via} denotes the length of the genome controlling viability, while L L denotes the overall length of the genome. The repair catastrophe therefore occurs when the repair error probability exceeds the fraction of deleterious mutations. Our model also gives a quantitative estimate for the equilibrium fraction of mutators in {\it Escherichia coli}.Comment: 4 pages, 2 figures (included as separate PS files

    Using audit and feedback to increase clinician adherence to clinical practice guidelines in brain injury rehabilitation: v

    Get PDF
    ObjectiveThis study evaluated whether frequent (fortnightly) audit and feedback cycles over a sustained period of time (>12 months) increased clinician adherence to recommended guidelines in acquired brain injury rehabilitation.DesignA before and after study design.SettingA metropolitan inpatient brain injury rehabilitation unit.ParticipantsClinicians; medical, nursing and allied health staff.InterventionsFortnightly cycles of audit and feedback for 14 months. Each fortnight, medical file and observational audits were completed against 114 clinical indicators.Main outcome measureAdherence to guideline indicators before and after intervention, calculated by proportions, Mann-Whitney U and Chi square analysis.ResultsClinical and statistical significant improvements in median clinical indicator adherence were found immediately following the audit and feedback program from 38.8% (95% CI 34.3 to 44.4) to 83.6% (95% CI 81.8 to 88.5). Three months after cessation of the intervention, median adherence had decreased from 82.3% to 76.6% (95% CI 72.7 to 83.3, pConclusionA fortnightly audit and feedback program increased clinicians’ adherence to guideline recommendations in an inpatient acquired brain injury rehabilitation setting. We propose future studies build on the evidence-based method used in the present study to determine effectiveness and develop an implementation toolkit for scale-up.</div

    CT Automated Exposure Control Using A Generalized Detectability Index

    Get PDF
    Purpose Identifying an appropriate tube current setting can be challenging when using iterative reconstruction due to the varying relationship between spatial resolution, contrast, noise, and dose across different algorithms. This study developed and investigated the application of a generalized detectability index (d\u27gen) to determine the noise parameter to input to existing automated exposure control (AEC) systems to provide consistent image quality (IQ) across different reconstruction approaches. Methods This study proposes a task‐based automated exposure control (AEC) method using a generalized detectability index (d\u27gen). The proposed method leverages existing AEC methods that are based on a prescribed noise level. The generalized d\u27gen metric is calculated using lookup tables of task‐based modulation transfer function (MTF) and noise power spectrum (NPS). To generate the lookup tables, the American College of Radiology CT accreditation phantom was scanned on a multidetector CT scanner (Revolution CT, GE Healthcare) at 120 kV and tube current varied manually from 20 to 240 mAs. Images were reconstructed using a reference reconstruction algorithm and four levels of an in‐house iterative reconstruction algorithm with different regularization strengths (IR1–IR4). The task‐based MTF and NPS were estimated from the measured images to create lookup tables of scaling factors that convert between d\u27gen and noise standard deviation. The performance of the proposed d\u27gen‐AEC method in providing a desired IQ level over a range of iterative reconstruction algorithms was evaluated using the American College of Radiology (ACR) phantom with elliptical shell and using a human reader evaluation on anthropomorphic phantom images. Results The study of the ACR phantom with elliptical shell demonstrated reasonable agreement between the d\u27gen predicted by the lookup table and d\u27 measured in the images, with a mean absolute error of 15% across all dose levels and maximum error of 45% at the lowest dose level with the elliptical shell. For the anthropomorphic phantom study, the mean reader scores for images resulting from the d\u27gen‐AEC method were 3.3 (reference image), 3.5 (IR1), 3.6 (IR2), 3.5 (IR3), and 2.2 (IR4). When using the d\u27gen‐AEC method, the observers’ IQ scores for the reference reconstruction were statistical equivalent to the scores for IR1, IR2, and IR3 iterative reconstructions (P \u3e 0.35). The d\u27gen‐AEC method achieved this equivalent IQ at lower dose for the IR scans compared to the reference scans. Conclusions A novel AEC method, based on a generalized detectability index, was investigated. The proposed method can be used with some existing AEC systems to derive the tube current profile for iterative reconstruction algorithms. The results provide preliminary evidence that the proposed d\u27gen‐AEC can produce similar IQ across different iterative reconstruction approaches at different dose levels

    New results from an extensive aging test on bakelite Resistive Plate Chambers

    Get PDF
    We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOhm to more than 250 MOhm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm2 to less than 0.15 kHz/cm2 is also found.Comment: 6 pages, 7 figures, presented at Siena 2002, 8th Topical Seminar on Innovative Particle and Radiation Detectors 21-24 October 2002, Siena, Ital

    Fatigue induced changes to kinematic and kinetic gait parameters following six minutes of walking in people with Multiple Sclerosis

    Get PDF
    This is an Accepted Manuscript of an article published by Taylor & Francis in Disability and Rehabilitation on 20 May 2015, available online: http://www.tandfonline.com/doi/abs/10.3109/09638288.2015.1047969Purpose: The aim of this study was to examine the effect of 6 min of walking on fatigue, exertion and spatiotemporal, kinematic and kinetic gait parameters in people with multiple sclerosis (MS). Methods: Thirty-four people with MS with moderate levels of disability completed measures of fatigue, exertion and instrumented gait analysis before and after 6-min trials of rest and walking (using a modified 6-min walk test, m6MWT). Ten age- and gender-matched healthy controls completed analysis before and after the m6MWT. Results: The MS group had a significant increase in self-reported fatigue following the m6MWT; however, there was no effect on spatiotemporal gait parameters. During stance on the more affected side ankle dorsiflexion at initial contact decreased, while knee and hip flexor moments and hip power absorption increased. On the less affected side ankle and knee power absorption, and hip extensor moment all increased. Healthy controls showed increases in joint kinetics likely due to increased walking speeds following m6MWT. Conclusion: For people with MS, ankle dorsiflexion angle reduces at initial contact following walking induced fatigue, while increased power absorption at the hip, knee and ankle indicate gait inefficiencies that may contribute to higher levels of fatigue and exertion. Implications for Rehabilitation The modified 6-min walk test (m6MWT) leads to significant increases in self-reported fatigue and exertion in people with MS. Following the m6MWT, there is significantly reduced ankle dorsiflexion angle at initial contact in the more affected leg in people with MS. This reveals an important walking-induced kinematic change that should be the target of future orthotic and strengthening interventions. In people with MS, increased power absorption primarily during the stance phase of gait following the m6MWT reveals important walking-induced muscle weakness that should also be monitored in future strengthening and gait retraining interventions

    Effect of wearing a dorsiflexion assist orthosis on mobility, perceived fatigue and exertion during the six-minute walk test in people with multiple sclerosis: a randomised cross-over protocol

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Background Fatigue in combination with gait and balance impairments can severely limit daily activities in people with multiple sclerosis (PWMS). Generalised fatigue has a major impact on walking ability, with moderately disabled PWMS experiencing difficulty in walking extended distances. Localised motor fatigue in the ankle dorsiflexors can lead to foot drop, further reducing functional ambulation. The aim of this study is to evaluate the effect of a simple dynamic dorsiflexion assist orthosis on walking-induced fatigue, gait, balance and functional mobility in PWMS. Methods A randomised cross-over trial will be conducted with 40 community dwelling PWMS with mild to moderate mobility disability. Participants will initially be screened for disease severity, balance, strength, depression and fatigue at the South Australian Motion Analysis Centre. On two non-consecutive occasions, within two weeks, participants will undergo either the 6-minute walk test (6MWT) or the 6MWT while wearing a dorsiflexion ankle orthosis (with a randomised condition order). Distance walked, perceived exertion, perceived fatigue and the physiological cost of walking (the primary outcome measures) will be compared between the two walking conditions. Additional pre- and post-6MWT assessments for the two conditions will include tests of strength, reaction time, gait and balance. Discussion This study will increase our understanding of motor fatigue on gait and balance control in PWMS and elucidate the effect of a Dynamic Ankle Orthosis on fatigue-related balance and gait in PWMS. It will also examine relationships between mobility and balance performance with perceived fatigue levels in this group

    Visual Field Dependence Is Associated with Reduced Postural Sway, Dizziness and Falls in Older People Attending a Falls Clinic.

    Get PDF
    Moving visual fields can have strong destabilising effects on balance, particularly when visually perceived motion does not correspond to postural movements. This study investigated relationships between visual field dependence (VFD), as assessed using the roll vection test, and reported dizziness, falls and sway under eyes open, eyes closed and optokinetic conditions. Ninety five falls clinic attendees undertook the roll vection test (i.e. attempted to align a rod to the vertical while exposed to a rotating visual field). Sway was assessed under different visual conditions by centre of pressure movement. Participants also completed questionnaires on space and motion discomfort, fear of falling, depression and anxiety. Thirty four (35.8%) participants exhibited VFD, i.e. had an error > 6.5º in the roll vection test. Compared to participants without VFD, participants with VFD demonstrated less movement of the centre of pressure across all visual conditions, were more likely to report space and motion discomfort and to have suffered more multiple falls in the past year. VFD was independent of fear of falling, anxiety and depression. VFD in a falls clinic population is associated with reduced sway possibly due to a stiffening strategy to maintain stance, dizziness symptoms and an increased risk of falls

    Promoting Activity in Geriatric Rehabilitation: A Randomized Controlled Trial of Accelerometry

    Get PDF
    This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Background Low activity levels in inpatient rehabilitation are associated with adverse outcomes. The study aimed to test whether activity levels can be increased by the provision of monitored activity data to patients and clinicians in the context of explicit goal setting. Methods A randomized controlled trial in three sites in Australia included 255 inpatients aged 60 and older who had a rehabilitation goal to become ambulant. The primary outcome was patients’ walking time measured by accelerometers during the rehabilitation admission. Walking times from accelerometry were made available daily to treating therapists and intervention participants to motivate patients to improve incidental activity levels and reach set goals. For the control group, ‘usual care’ was followed, including the setting of mobility goals; however, for this group, neither staff nor patients received data on walking times to aid the setting of daily walking time targets. Results The median daily walking time in the intervention group increased from 10.3 minutes at baseline to 32.1 minutes at day 28, compared with an increase from 9.5 to 26.5 minutes per day in the control group. Subjects in the intervention group had significantly higher non-therapy walking time by about 7 minutes [mean (95% CI): 24.6 (21.7, 27.4)] compared to those in the control group [mean(95% CI): 17.3 (14.4, 20.3)] (p = 0.001). Conclusions Daily feedback to patients and therapists using an accelerometer increased walking times during rehabilitation admissions. The results of this study suggest objective monitoring of activity levels could provide clinicians with information on clinically important, mobility-related activities to assist goal setting. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12611000034932 http://www.ANZCTR.org.au
    corecore