287 research outputs found

    Precision measurement of the neutrino velocity with the ICARUS detector in the CNGS beam

    Get PDF
    During May 2012, the CERN-CNGS neutrino beam has been operated for two weeks for a total of 1.8 10^17 pot in bunched mode, with a 3 ns narrow width proton beam bunches, separated by 100 ns. This tightly bunched beam structure allows a very accurate time of flight measurement of neutrinos from CERN to LNGS on an event-by-event basis. Both the ICARUS-T600 PMT-DAQ and the CERN-LNGS timing synchronization have been substantially improved for this campaign, taking ad-vantage of additional independent GPS receivers, both at CERN and LNGS as well as of the deployment of the "White Rabbit" protocol both at CERN and LNGS. The ICARUS-T600 detector has collected 25 beam-associated events; the corresponding time of flight has been accurately evaluated, using all different time synchronization paths. The measured neutrino time of flight is compatible with the arrival of all events with speed equivalent to the one of light: the difference between the expected value based on the speed of light and the measured value is tof_c - tof_nu = (0.10 \pm 0.67stat. \pm 2.39syst.) ns. This result is in agreement with the value previously reported by the ICARUS collaboration, tof_c - tof_nu = (0.3 \pm 4.9stat. \pm 9.0syst.) ns, but with improved statistical and systematic errors.Comment: 21 pages, 13 figures, 1 tabl

    Application of Graphene within Optoelectronic Devices and Transistors

    Full text link
    Scientists are always yearning for new and exciting ways to unlock graphene's true potential. However, recent reports suggest this two-dimensional material may harbor some unique properties, making it a viable candidate for use in optoelectronic and semiconducting devices. Whereas on one hand, graphene is highly transparent due to its atomic thickness, the material does exhibit a strong interaction with photons. This has clear advantages over existing materials used in photonic devices such as Indium-based compounds. Moreover, the material can be used to 'trap' light and alter the incident wavelength, forming the basis of the plasmonic devices. We also highlight upon graphene's nonlinear optical response to an applied electric field, and the phenomenon of saturable absorption. Within the context of logical devices, graphene has no discernible band-gap. Therefore, generating one will be of utmost importance. Amongst many others, some existing methods to open this band-gap include chemical doping, deformation of the honeycomb structure, or the use of carbon nanotubes (CNTs). We shall also discuss various designs of transistors, including those which incorporate CNTs, and others which exploit the idea of quantum tunneling. A key advantage of the CNT transistor is that ballistic transport occurs throughout the CNT channel, with short channel effects being minimized. We shall also discuss recent developments of the graphene tunneling transistor, with emphasis being placed upon its operational mechanism. Finally, we provide perspective for incorporating graphene within high frequency devices, which do not require a pre-defined band-gap.Comment: Due to be published in "Current Topics in Applied Spectroscopy and the Science of Nanomaterials" - Springer (Fall 2014). (17 pages, 19 figures

    Modeling the natural gas knocking behaviour using gas-phase infrared spectra and multivariate calibration

    Get PDF
    [Abstract] To assess the knocking properties of natural gas (NG) when it is used as fuel for vehicles is vital to optimize the design and functioning of their motors. Analytical efforts in this field are needed as the engines used to define it empirically are not available anymore, and existent mathematical algorithms yield different accuracy. The hybridization of gas-phase infrared spectrometry and partial least squares multivariate regression is presented first time to address the determination of the methane number (MN) of NG samples. It circumvents the need for the previous knowledge of the NG composition required to apply dedicated equations. The use of true NG samples to develop the models is also quite new in the field. Proof-of-concept studies were made with synthetic spectra and, then, a collection of liquefied NG samples for which MN values were computed by the National Physics Laboratory algorithm (NPL) from their sample composition were used to develop operative models. Additional validation was made with a collection of synthetic standard mixtures prepared for two European projects (EMRP LNG II and EMPIR LNG III) whose service methane numbers (SMN) were measured with an engine. The FTIR-PLS approach yielded statistically unbiased predictions with average standard errors around 0.4% MN when compared to the NPL-MN and SMN values, and standard deviations of the means ca. 1% MN. The approach is fast, cost effective as it involves standard instrumentation, and can be considered compliant with the green chemistry principles.This work is part of the EMPIR 16ENG09 project ‘Metrological support for LNG and LBG as transport fuel (LNG III)’. This project has received funding from the EMPIR programme co-financed by the Participant States and from the European Union's Horizon 2020 Research and Innovation programme. The authors from TU Braunschweig would like to thank IAV, Mahle, MAN Truck & Bus and Motortech for their support in preparing the test engine. The Group of Applied Analytical Chemistry of the University of A Coruña acknowledges Mestrelab, Reganosa and Naturgy for hiring its services for FTIR method developmentFinanciado para publicación en acceso aberto: Universidade da Coruña/CISU

    Functional consequences of microbial shifts in the human gastrointestinal tract linked to antibiotic treatment and obesity

    Get PDF
    The microbiomes in the gastrointestinal tract (GIT) of individuals receiving antibiotics and those in obese subjects undergo compositional shifts, the metabolic effects and linkages of which are not clearly understood. Herein, we set to gain insight into these effects, particularly with regard to carbohydrate metabolism, and to contribute to unravel the underlying mechanisms and consequences for health conditions. We measured the activity level of GIT carbohydrate-active enzymes toward 23 distinct sugars in adults patients (n = 2) receiving 14-d β-lactam therapy and in obese (n = 7) and lean (n = 5) adolescents. We observed that both 14 d antibiotic-treated and obese subjects showed higher and less balanced sugar anabolic capacities, with 40% carbohydrates being preferentially processed as compared with non-treated and lean patients. Metaproteome-wide metabolic reconstructions confirmed that the impaired utilization of sugars propagated throughout the pentose phosphate metabolism, which had adverse consequences for the metabolic status of the GIT microbiota. The results point to an age-independent positive association between GIT glycosidase activity and the body mass index, fasting blood glucose and insulin resistance (r2 ≥ 0.95). Moreover, antibiotics altered the active fraction of enzymes controlling the thickness, composition and consistency of the mucin glycans. Our data and analyses provide biochemical insights into the effects of antibiotic usage on the dynamics of the GIT microbiota and pin-point presumptive links to obesity. The knowledge and the hypotheses generated herein lay a foundation for subsequent, systematic research that will be paramount for the design of “smart” dietary and therapeutic interventions to modulate host-microbe metabolic co-regulation in intestinal homeostasis
    corecore