562 research outputs found

    High-purity material selection techniques for Rare-Events Physics experiments

    Get PDF
    In experiments on Rare-Events Physics it is important that the construction materials, in particular those closer to the detectors, have the smallest amount of contaminants that can contribute to background. Copper is a material widely used thanks to its low content in radioactive contaminants, so it is very important to develop tools able to reach high sensitivity in the analysis of Copper radioactivity. A method based on Neutron Activation Analysis (NAA) has been developed to analyze 232Th contamination in copper samples through the irradiation of 200 g of copper then radiochemical concentrated using nitric acid and actinide resin. Several elutions with various inorganic acids were done to concentrate 233Pa, activation product of 232Th, from copper matrix to eliminate radioactive contribution from other activation products. Using gamma spectroscopy with HPGe to evaluate the radioactivity due to gamma rays from 233Pa decay it was possible to reach a detection limit of 5 × 10−13g232Th/gCu

    Relationship between device acceptance and patient-reported outcomes in left ventricular assist device (LVAD) recipients

    Get PDF
    The number of Left Ventricular Assist Devices (LVADs) implanted each year is rising. Nevertheless, there are minimal data on device acceptance after LVAD implant, and on its relationship with patient-reported outcomes. We designed a cross-sectional study to address this knowledge gap and test the hypothesis that low device acceptance is associated with poorer quality of life, depression and anxiety. Self-report questionnaires were administered to assess quality of life (12-item Kansas City Cardiomyopathy Questionnaire quality of life subscale), level of anxiety (7-item Generalized Anxiety Disorder; GAD-7), level of depression (9-item Patient Health Questionnaire; PHQ-9) and device acceptance (Florida Patient Acceptance Survey; FPAS) to 101 consecutive patients presenting to LVAD clinic. Regression analysis showed a strong correlation between device acceptance and both psychological distress (p\u2009<\u20090.001) and quality of life (p\u2009<\u20090.001). Analysis of the sub-scales of the FPAS showed that patients had significant body image concerns, but return to function and device-related distress were the main drivers of the observed correlation between device acceptance and patient well-being. Younger age was associated with lower device acceptance (r\u2009=\u20090.36, p\u2009<\u20090.001) and lower quality of life (r\u2009=\u20090.54, p\u2009<\u20090.001). These findings suggest that interventions targeting device acceptance should be explored to improve outcomes in LVAD recipients

    The 4 K outer cryostat for the CUORE experiment: construction and quality control

    Full text link
    The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell were produced and delivered to the Gran Sasso underground Laboratories in July 2012. In this paper, we describe the production techniques and the validation tests done at the production site in 2012.Comment: 11 pages, 13 figures; to appear in NIM

    Usefulness of regional right ventricular and right atrial strain for prediction of early and late right ventricular failure following a left ventricular assist device implant: A machine learning approach

    Get PDF
    Background: Identifying candidates for left ventricular assist device surgery at risk of right ventricular failure remains difficult. The aim was to identify the most accurate predictors of right ventricular failure among clinical, biological, and imaging markers, assessed by agreement of different supervised machine learning algorithms. Methods: Seventy-four patients, referred to HeartWare left ventricular assist device since 2010 in two Italian centers, were recruited. Biomarkers, right ventricular standard, and strain echocardiography, as well as cath-lab measures, were compared among patients who did not develop right ventricular failure (N = 56), those with acute–right ventricular failure (N = 8, 11%) or chronic–right ventricular failure (N = 10, 14%). Logistic regression, penalized logistic regression, linear support vector machines, and naïve Bayes algorithms with leave-one-out validation were used to evaluate the efficiency of any combination of three collected variables in an “all-subsets” approach. Results: Michigan risk score combined with central venous pressure assessed invasively and apical longitudinal systolic strain of the right ventricular–free wall were the most significant predictors of acute–right ventricular failure (maximum receiver operating characteristic–area under the curve = 0.95, 95% confidence interval = 0.91–1.00, by the naïve Bayes), while the right ventricular–free wall systolic strain of the middle segment, right atrial strain (QRS-synced), and tricuspid annular plane systolic excursion were the most significant predictors of Chronic-RVF (receiver operating characteristic–area under the curve = 0.97, 95% confidence interval = 0.91–1.00, according to naïve Bayes). Conclusion: Apical right ventricular strain as well as right atrial strain provides complementary information, both critical to predict acute–right ventricular failure and chronic–right ventricular failure, respectively

    Puma predation on radiocollared and uncollared bighorn sheep

    Get PDF
    BackgroundWe used Global Positioning System (GPS) data from radiocollared pumas (Puma concolor) to identify kill sites of pumas preying upon an endangered population of bighorn sheep (Ovis canadensis) in southern California. Our aims were to test whether or not pumas selected radiocollared versus uncollared bighorn sheep, and to identify patterns of movement before, during, and after kills.FindingsThree pumas killed 23 bighorn sheep over the course of the study, but they did not preferentially prey on marked (radiocollared) versus unmarked bighorn sheep. Predation occurred primarily during crepuscular and nighttime hours, and 22 kill sites were identified by the occurrence of 2 or more consecutive puma GPS locations (a cluster) within 200 m of each other at 1900, 0000, and 0600 h.ConclusionWe tested the "conspicuous individual hypothesis" and found that there was no difference in puma predation upon radiocollared and uncollared bighorn sheep. Pumas tended to move long distances before and after kills, but their movement patterns immediately post-kill were much more restricted. Researchers can exploit this behaviour to identify puma kill sites and investigate prey selection by designing studies that detect puma locations that are spatially clustered between dusk and dawn

    Large area Si low-temperature light detectors with Neganov-Luke effect

    Full text link
    Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors are the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performance thanks to the use of the Neganov-Luke effect is described. The aim of this research line is the production of high performance detectors with industrial-grade reproducibility and reliability.Comment: 4 pages, 2 figure

    Sant'Imbenia (Alghero): further archaeometric evidence for an Iron Age market square

    Get PDF
    AbstractLead isotope compositions were determined for 18 metal objects from the archaeological site of Sant'Imbenia, NW Sardinia, dating to the end of the ninth century BCE onwards. The provenance of some objects is unambiguously traced to SW Sardinia; other objects could derive either from central Sardinia or the Iberian coastal ranges. The variety of the provenances attests to a wide trade network that spanned the entire island of Sardinia and extended to the Iberian sites

    Reducing the impact of radioactivity on quantum circuits in a deep-underground facility

    Get PDF
    As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor fifty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware
    corecore