72 research outputs found

    A Novel Biomimetic Tool for Assessing Vitamin K Status Based on Molecularly Imprinted Polymers

    Get PDF
    Vitamin K was originally discovered as a cofactor required to activate clotting factors and has recently been shown to play a key role in the regulation of soft tissue calcification. This property of vitamin K has led to an increased interest in novel methods for accurate vitamin K detection. Molecularly Imprinted Polymers (MIPs) could offer a solution, as they have been used as synthetic receptors in a large variety of biomimetic sensors for the detection of similar molecules over the past few decades, because of their robust nature and remarkable selectivity. In this article, the authors introduce a novel imprinting approach to create a MIP that is able to selectively rebind vitamin K 1. As the native structure of the vitamin does not allow for imprinting, an alternative imprinting strategy was developed, using the synthetic compound menadione (vitamin K 3) as a template. Target rebinding was analyzed by means of UV-visible (UV-VIS) spectroscopy and two custom-made thermal readout techniques. This analysis reveals that the MIP-based sensor reacts to an increasing concentration of both menadione and vitamin K 1. The Limit of Detection (LoD) for both compounds was established at 700 nM for the Heat Transfer Method (HTM), while the optimized readout approach, Thermal Wave Transport Analysis (TWTA), displayed an increased sensitivity with a LoD of 200 nM. The sensor seems to react to a lesser extent to Vitamin E, the analogue under study. To further demonstrate its potential application in biochemical research, the sensor was used to measure the absorption of vitamin K in blood serum after taking vitamin K supplements. By employing a gradual enrichment strategy, the sensor was able to detect the difference between baseline and peak absorption samples and was able to quantify the vitamin K concentration in good agreement with a validation experiment using High-Performance Liquid Chromatography (HPLC). In this way, the authors provide a first proof of principle for a low-cost, straightforward, and label-free vitamin K sensor

    Label-free protein detection based on the heat-transfer method-a case study with the peanut allergen Ara h 1 and aptamer-based synthetic receptors

    Get PDF
    © 2015 American Chemical Society. Aptamers are an emerging class of molecules that, because of the development of the systematic evolution of ligands by exponential enrichment (SELEX) process, can recognize virtually every target ranging from ions, to proteins, and even whole cells. Although there are many techniques capable of detecting template molecules with aptamer-based systems with high specificity and selectivity, they lack the possibility of integrating them into a compact and portable biosensor setup. Therefore, we will present the heat-transfer method (HTM) as an interesting alternative because this offers detection in a fast and low-cost manner and has the possibility of performing experiments with a fully integrated device. This concept has been demonstrated for a variety of applications including DNA mutation analysis and screening of cancer cells. To the best our knowledge, this is the first report on HTM-based detection of proteins, in this case specifically with aptamer-type receptors. For proof-of-principle purposes, measurements will be performed with the peanut allergen Ara h 1 and results indicate detection limits in the lower nanomolar regime in buffer liquid. As a first proof-of-application, spiked Ara h 1 solutions will be studied in a food matrix of dissolved peanut butter. Reference experiments with the quartz-crystal microbalance will allow for an estimate of the areal density of aptamer molecules on the sensor-chip surface

    Fingerprints for Structural Defects in Poly(thienylene vinylene) (PTV): A Joint Theoretical–Experimental NMR Study on Model Molecules

    Full text link
    In the field of plastic electronics, low band gap conjugated polymers like poly(thienylene vinylene) (PTV) and its derivatives are a promising class of materials that can be obtained with high molecular weight via the so-called dithiocarbamate precursor route. We have performed a joint experimental- theoretical study of the full NMR chemical shift assignment in a series of thiophene-based model compounds, which aims at (i) benchmarking the quantum-chemical calculations against experiments, (ii) identifying the signature of possible structural defects that can appear during the polymerization of PTV's, namely head-to-head and tail-to-tail defects, and (iii) defining a criterion regarding regioregularity

    Towards water compatible MIPs for sensing in aqueous media

    No full text
    When synthesizing molecularly imprinted polymers (MIPs), a few fundamental principles should be kept in mind. There is a strong correlation between porogen polarity, MIP microenvironment polarity and the imprinting effect itself. The combination of these parameters eventually determines the overall binding behavior of a MIP in a given solvent. In addition, it is shown that MIP binding is strongly influenced by the polarity of the rebinding solvent. Because the use of MIPs in biomedical environments is of considerable interest, it is important that these MIPs perform well in aqueous media. In this article, various approaches are explored towards a water compatible MIP for the target molecule l-nicotine. To this end, the imprinting effect together with the MIP matrix polarity is fine-tuned during MIP synthesis. The binding behavior of the resulting MIPs is evaluated by performing batch rebinding experiments that makes it possible to select the most suitable MIP/non-imprinted polymer couple for future application in aqueous environments. One method to achieve improved compatibility with water is referred to as porogen tuning, in which porogens of varying polarities are used. It is demonstrated that, especially when multiple porogens are mixed, this approach can lead to superior performance in aqueous environments. Another method involves the incorporation of polar or non-polar comonomers in the MIP matrix. It is shown that by carefully selecting these monomers, it is also possible to obtain MIPs, which can selectively bind their target in water. © 2012 John Wiley & Sons, Ltd

    The synthesis of poly(thienylene vinylene) derivatives via the dithiocarbamate route: low band gap p-type conjugated polymers for photovoltaics

    No full text
    Poly(2,5-thienylene vinylene), PTV and its soluble alkyl derivatives were synthesised using the dithiocarbamate precursor route (DTC-route) in a good yield, with high molecular weight (Mw), low polydispersity (PD), and with a high maximum absorption peak, λmax\lambda_{max}. The polymers were characterised by absorption spectroscopy, cyclic voltammetry and, X-ray diffraction

    Identification and Quantification of Defect Structures in Poly(2,5-thienylene vinylene) Derivatives Prepared via the Dithiocarbamate Precursor Route by Means of NMR Spectroscopy on C-13-Labeled Polymers

    No full text
    International audienceDuring the past decades several synthetic routes toward the low band gap polymer poly(2,5-thienylene vinylene) (PTV) and derivatives have been studied. This study describes an extensive NMR characterization of 13C-labeled 3-octyl-PTV and its precursor polymer prepared via the dithiocarbamate route which is, since stable monomers are available, a promising route toward PTV derivatives. By introducing 13C-labeled vinylene carbons, we were able to characterize these polymers in a quantitative way, taking the end groups and structural polymerization defects, which disturb the conjugated system, into account. Several NMR techniques and the synthesis of model compounds were used to fully assign the proton and carbon chemical shifts. Moreover, the classically used thermal conversion of the precursor toward the conjugated polymer has been compared to a smoother, acid-induced elimination procedure
    • …
    corecore