407 research outputs found
Recommended from our members
Evolution of superconductivity in K2-xFe4+ySe5: Spectroscopic studies of X-ray absorption and emission.
This study investigates the evolution of superconductivity in K2-xFe4+ySe5 using temperature-dependent X-ray absorption and resonant inelastic X-ray scattering techniques. Magnetization measurements show that polycrystalline superconducting (SC) K1.9Fe4.2Se5 has a critical temperature (T c) of ∼31 K with a varying superconducting volume fraction, which strongly depends on its synthesis temperature. An increase in Fe-structural/vacancy disorder in SC samples with more Fe atoms occupying vacant 4d sites is found to be closely related to the decrease in the spin magnetic moment of Fe. Moreover, the nearest-neighbor Fe-Se bond length in SC samples exceeds that in the non-SC (NS) sample, K2Fe4Se5, which indicates a weaker hybridization between the Fe 3d and Se 4p states in SC samples. These results clearly demonstrate the correlations among the local electronic and atomic structures and the magnetic properties of K2-xFe4+ySe5 superconductors, providing deeper insight into the electron pairing mechanisms of superconductivity
Fingerprint oxygen redox reactions in batteries through high-efficiency mapping of resonant inelastic X-ray scattering
Realizing reversible reduction-oxidation (redox) reactions of lattice oxygen in batteries is a promising way to improve the energy and power density. However, conventional oxygen absorption spectroscopy fails to distinguish the critical oxygen chemistry in oxide-based battery electrodes. Therefore, high-efficiency full-range mapping of resonant inelastic X-ray scattering (mRIXS) has been developed as a reliable probe of oxygen redox reactions. Here, based on mRIXS results collected from a series of Li Ni Co Mn O electrodes at different electrochemical states and its comparison with peroxides, we provide a comprehensive analysis of five components observed in the mRIXS results. While all the five components evolve upon electrochemical cycling, only two of them correspond to the critical states associated with oxygen redox reactions. One is a specific feature at 531.0 eV excitation and 523.7 eV emission energy, the other is a low-energy loss feature. We show that both features evolve with electrochemical cycling of Li Ni Co Mn O electrodes, and could be used for characterizing oxidized oxygen states in the lattice of battery electrodes. This work provides an important benchmark for a complete assignment of all mRIXS features collected from battery materials, which sets a general foundation for future studies in characterization, analysis, and theoretical calculation for probing and understanding oxygen redox reactions. 1.17 0.21 0.08 0.54 2 1.17 0.21 0.08 0.54
Recommended from our members
MERLIN - A meV resolution beamline at the ALS
An ultra-high resolution beamline is being constructed at the Advanced Light Source (ALS) for the study of low energy excitations in strongly correlated systems with the use of high-resolution inelastic scattering and angle-resolved photoemission. This new beamline, given the acronym Merlin (for meV resolution line), will cover the energy range 10-150 eV. The monochromator has fixed entrance and exit slits and a plane mirror that can illuminate a spherical grating at the required angle of incidence (as in the SX-700 mechanism). The monochromator can be operated in two different modes. In the highest resolution mode, the energy scanning requires translating the monochromator chamber (total travel 1.1 m) as well as rotating the grating and the plane mirror in front of the grating. The resolution in this mode is practically determined by the slits width. In the second mode, the scanning requires rotating the grating and the plane mirror. This mode can be used to scan a few eV without a significant resolution loss. The source for the beamline is a 1.9 m long, 90 mm period quasi periodic EPU. The expected flux at the sample is higher than 10 photons/s at a resolving power of 5 × 10 in the energy range 16-130 eV. A second set of gratings can be used to obtain higher flux at the expense of resolution. © 2007 American Institute of Physics. 11
Momentum-resolved resonant inelastic soft X-ray scattering (qRIXS) endstation at the ALS
A momentum resolved resonant inelastic X-ray scattering (qRIXS) experimental station with continuously rotatable spectrometers and parallel detection is designed to operate at different beamlines at synchrotron and free electron laser (FEL) facilities. This endstation, currently located at the Advanced Light Source (ALS), has five emission ports on the experimental chamber for mounting the high-throughput modular soft X-ray spectrometers (MXS) [24]. Coupled to the rotation from the supporting hexapod, the scattered X-rays from 27.5° (forward scattering) to 152.5° (backward scattering) relative to the incident photon beam can be recorded, enabling the momentum-resolved RIXS spectroscopy. The components of this endstation are described in details, and the preliminary RIXS measurements on highly oriented pyrolytic graphite (HOPG) reveal the low energy vibronic excitations from the strong electron-phonon coupling at C K edge around σ* band. The grating upgrade option to enhance the performance at low photon energies is presented and the potential of this spectroscopy is discussed in summary
ARPES: A probe of electronic correlations
Angle-resolved photoemission spectroscopy (ARPES) is one of the most direct
methods of studying the electronic structure of solids. By measuring the
kinetic energy and angular distribution of the electrons photoemitted from a
sample illuminated with sufficiently high-energy radiation, one can gain
information on both the energy and momentum of the electrons propagating inside
a material. This is of vital importance in elucidating the connection between
electronic, magnetic, and chemical structure of solids, in particular for those
complex systems which cannot be appropriately described within the
independent-particle picture. Among the various classes of complex systems, of
great interest are the transition metal oxides, which have been at the center
stage in condensed matter physics for the last four decades. Following a
general introduction to the topic, we will lay the theoretical basis needed to
understand the pivotal role of ARPES in the study of such systems. After a
brief overview on the state-of-the-art capabilities of the technique, we will
review some of the most interesting and relevant case studies of the novel
physics revealed by ARPES in 3d-, 4d- and 5d-based oxides.Comment: Chapter to appear in "Strongly Correlated Systems: Experimental
Techniques", edited by A. Avella and F. Mancini, Springer Series in
Solid-State Sciences (2013). A high-resolution version can be found at:
http://www.phas.ubc.ca/~quantmat/ARPES/PUBLICATIONS/Reviews/ARPES_Springer.pdf.
arXiv admin note: text overlap with arXiv:cond-mat/0307085,
arXiv:cond-mat/020850
Precision measurement of the top quark mass from dilepton events at CDF II
We report a measurement of the top quark mass, M_t, in the dilepton decay
channel of
using an integrated luminosity of 1.0 fb^{-1} of p\bar{p} collisions collected
with the CDF II detector. We apply a method that convolutes a leading-order
matrix element with detector resolution functions to form event-by-event
likelihoods; we have enhanced the leading-order description to describe the
effects of initial-state radiation. The joint likelihood is the product of the
likelihoods from 78 candidate events in this sample, which yields a measurement
of M_{t} = 164.5 \pm 3.9(\textrm{stat.}) \pm 3.9(\textrm{syst.})
\mathrm{GeV}/c^2, the most precise measurement of M_t in the dilepton channel.Comment: 7 pages, 2 figures, version includes changes made prior to
publication by journa
Cross Section Measurements of High- Dilepton Final-State Processes Using a Global Fitting Method
We present a new method for studying high- dilepton events
(, , ) and simultaneously
extracting the production cross sections of , , and p\bar{p} \to \ztt at a center-of-mass energy of TeV. We perform a likelihood fit to the dilepton data in a parameter
space defined by the missing transverse energy and the number of jets in the
event. Our results, which use of data recorded with the CDF
II detector at the Fermilab Tevatron Collider, are pb, pb, and
\sigma(\ztt) =291^{+50}_{-46} pb.Comment: 20 pages, 2 figures, to be submitted to PRD-R
Measurement of the Ratios of Branching Fractions B(Bs -> Ds pi pi pi) / B(Bd -> Dd pi pi pi) and B(Bs -> Ds pi) / B(Bd -> Dd pi)
Using 355 pb^-1 of data collected by the CDF II detector in \ppbar collisions
at sqrt{s} = 1.96 TeV at the Fermilab Tevatron, we study the fully
reconstructed hadronic decays B -> D pi and B -> D pi pi pi. We present the
first measurement of the ratio of branching fractions B(Bs -> Ds pi pi pi) /
B(Bd -> Dd pi pi pi) = 1.05 pm 0.10 (stat) pm 0.22 (syst). We also update our
measurement of B(Bs -> Ds pi) / B(Bd -> Dd pi) to 1.13 pm 0.08 (stat) pm 0.23
(syst) improving the statistical uncertainty by more than a factor of two. We
find B(Bs -> Ds pi) = [3.8 pm 0.3 (stat) pm 1.3 (syst)] \times 10^{-3} and B(Bs
-> Ds pi pi pi) = [8.4 pm 0.8 (stat) pm 3.2 (syst)] \times 10^{-3}.Comment: 7 pages, 2 figure
- …