72 research outputs found

    Precise measurement of the Bragg curve for 800 MeV/u 238^{238}U ions stopping in polyethylene and its implications for calculation of heavy ion ranges

    Get PDF
    Stopping power predictions in radiation transport codes are based on the Bethe-Bloch formula and different corrections. For very heavy ions at relativistic energies the available experimental data are scarce and therefore verification of stopping power predictions is only possible to a limited extent. In this work, a full experimental Bragg curve for 800 MeV/u 238^{238}U ions stopping in polyethylene is presented. The measurements were conducted at the experimental area Cave A at GSI Helmholtzzentrum fĂĽr Schwerionenforschung in Darmstadt, Germany. The 800 MeV/u 238^{238}U beam was provided by the SIS18 heavy ion synchrotron. The Bragg curve was measured with a setup consisting of a binary range shifter and two large area parallel plate ionization chambers. Complementary Monte Carlo simulations using the FLUKA code were performed and compared with the experimental Bragg curve. The mean ionization potential of polyethylene was fine-tuned to match the measured primary ion range with FLUKA simulations. The impact of the Bloch and Mott corrections to the stopping power calculation were studied by switching them off intentionally in separate simulations. A detailed description of the implementation of the stopping power formulae and the Mott correction in FLUKA is provided

    Investigating Slit-Collimator-Produced Carbon Ion Minibeams with High-Resolution CMOS Sensors

    Get PDF
    Particle minibeam therapy has demonstrated the potential for better healthy tissue sparing due to spatial fractionation of the delivered dose. Especially for heavy ions, the spatial fractionation could enhance the already favorable differential biological effectiveness at the target and the entrance region. Moreover, spatial fractionation could even be a viable option for bringing ions heavier than carbon back into patient application. To understand the effect of minibeam therapy, however, requires careful conduction of pre-clinical experiments, for which precise knowledge of the minibeam characteristics is crucial. This work introduces the use of high-spatial-resolution CMOS sensors to characterize collimator-produced carbon ion minibeams in terms of lateral fluence distribution, secondary fragments, track-averaged linear energy transfer distribution, and collimator alignment. Additional simulations were performed to further analyze the parameter space of the carbon ion minibeams in terms of beam characteristics, collimator positioning, and collimator manufacturing accuracy. Finally, a new concept for reducing the neutron dose to the patient by means of an additional neutron shield added to the collimator setup is proposed and validated in simulation. The carbon ion minibeam collimator characterized in this work is used in ongoing pre-clinical experiments on heavy ion minibeam therapy at the GSI

    Experimental Comparison of Fiducial Markers Used in Proton Therapy: Study of Different Imaging Modalities and Proton Fluence Perturbations Measured With CMOS Pixel Sensors

    Get PDF
    Fiducial markers are used for image guidance to verify the correct positioning of the target for the case of tumors that can suffer interfractional motion during proton therapy. The markers should be visible on daily imaging, but at the same time, they should produce minimal streak artifacts in the CT scans for treatment planning and induce only slight dose perturbations during particle therapy. In this work, these three criteria were experimentally investigated at the Heidelberg Ion Beam Therapy Center. Several small fiducial markers with different geometries and materials (gold, platinum, and carbon-coated ZrO₂) were evaluated. The streak artifacts on treatment planning CT were measured with and without iMAR correction, showing significantly smaller artifacts from markers lighter than 6 mg and a clear improvement with iMAR correction. Daily imaging as X-ray projections and in-room mobile CT were also performed. Markers heavier than 6 mg showed a better contrast in the X-ray projections, whereas on the images from the in-room mobile CT, all markers were clearly visible. In the other part of this work, fluence perturbations of proton beams were measured for the same markers by using a tracker system of several high spatial resolution CMOS pixel sensors. The measurements were performed for single-energy beams, as well as for a spread-out Bragg peak. Three-dimensional fluence distributions were computed after reconstructing all particle trajectories. These measurements clearly showed that the ZrO₂ markers and the low-mass gold/platinum markers (0.35mm diameter) induce perturbations being 2–3 times lower than the heavier gold or platinum markers of 0.5mm diameter. Monte Carlo simulations, using the FLUKA code, were used to compute dose distributions and showed good agreement with the experimental data after adjusting the phase space of the simulated proton beam compared to the experimental beam

    Helium ions for radiotherapy? Physical and biological verifications of a novel treatment modality

    Get PDF
    Purpose: Modern facilities for actively scanned ion beam radiotherapy allow in principle the use of helium beams, which could present specific advantages, especially for pediatric tumors. In order to assess the potential use of these beams for radiotherapy, i.e., to create realistic treatment plans, the authors set up a dedicated He-4 beam model, providing base data for their treatment planning system TRiP98, and they have reported that in this work together with its physical and biological validations. Methods: A semiempirical beam model for the physical depth dose deposition and the production of nuclear fragments was developed and introduced in TRiP98. For the biological effect calculations the last version of the local effect model was used. The model predictions were experimentally verified at the HIT facility. The primary beam attenuation and the characteristics of secondary charged particles at various depth in water were investigated using He-4 ion beams of 200 MeV/u. The nuclear charge of secondary fragments was identified using a Delta E/E telescope. 3D absorbed dose distributions were measured with pin point ionization chambers and the biological dosimetry experiments were realized irradiating a Chinese hamster ovary cells stack arranged in an extended target. Results: The few experimental data available on basic physical processes are reproduced by their beam model. The experimental verification of absorbed dose distributions in extended target volumes yields an overall agreement, with a slight underestimation of the lateral spread. Cell survival along a 4 cm extended target is reproduced with remarkable accuracy. Conclusions: The authors presented a simple simulation model for therapeutical He-4 beams which they introduced in TRiP98, and which is validated experimentally by means of physical and biological dosimetries. Thus, it is now possible to perform detailed treatment planning studies with He-4 beams, either exclusively or in combination with other ion modalities. (C) 2016 Author(s)

    FOOT: a new experiment to measure nuclear fragmentation at intermediate energies

    Get PDF
    Summary: Charged particle therapy exploits proton or 12C beams to treat deep-seated solid tumors. Due to the advantageous characteristics of charged particles energy deposition in matter, the maximum of the dose is released to the tumor at the end of the beam range, in the Bragg peak region. However, the beam nuclear interactions with the patient tissues induces fragmentation both of projectile and target nuclei and needs to be carefully taken into account. In proton treatments, target fragmentation produces low energy, short range fragments along all the beam range, which deposit a non negligible dose in the entry channel. In 12C treatments the main concern is represented by long range fragments due to beam fragmentation that release their dose in the healthy tissues beyond the tumor. The FOOT experiment (FragmentatiOn Of Target) of INFN is designed to study these processes, in order to improve the nuclear fragmentation description in next generation Treatment Planning Systems and the treatment plans quality. Target (16O and 12C nuclei) fragmentation induced by –proton beams at therapeutic energies will be studied via an inverse kinematic approach, where 16O and 12C therapeutic beams impinge on graphite and hydrocarbon targets to provide the nuclear fragmentation cross section on hydrogen. Projectile fragmentation of 16O and 12C beams will be explored as well. The FOOT detector includes a magnetic spectrometer for the fragments momentum measurement, a plastic scintillator for ΔE and time of flight measurements and a crystal calorimeter to measure the fragments kinetic energy. These measurements will be combined in order to make an accurate fragment charge and isotopic identification. Keywords: Hadrontherapy, Nuclear fragmentation cross sections, Tracking detectors, Scintillating detector

    Fragmentation of 400 MeV/u 12C on a thin graphite target

    Get PDF
    Detailed understanding of high energetic heavy ions interacting with matter is of great interest in basic research and applied physics especially in radiotherapy and space radioprotection. Radiotherapy with carbon ions showed great success especially in the treatment of deep seated tumors due to the favorable depth-dose profile and increased biological effectiveness compared to photons or protons. Due to nuclear interactions between the primary beam and the patient's body, usually only 50% of the carbon ions will reach the target location. Thus, a detailed knowledge of the changes in the radiation field is required for delivering a successful treatment. The radiation environment in space is composed of high energy charged particles and can lead to serious health risks for astronauts. The assessment and mitigation of radioinduced health complications cannot be accomplished without a good understanding of the interaction of the mixed radiation field with e.g. the hull of the spaceship or lunar soil. In this work the fragmentation of 400 MeV/u 12C on a thin graphite target was investigated. The resulting angular yield distributions and differential energy spectra of charged and uncharged particles are presented and compared to two different Monte Carlo codes (PHITS and GEANT4)

    Bestrahlungsphantom mit zumindest einer Bewegungsvorrichtung zur Bewegung eines ersten Teilbereichs

    No full text
    Die Erfindung betrifft eine Bestrahlungsphantomvorrichtung zur Validierung einer Bestrahlungsplanung, die eine Bewegungsvorrichtung zur Bewegung von einem ersten Teilbereich der Bestrahlungsphantomvorrichtung relativ zu einem zweiten Teilbereich der Bestrahlungsphantomvorrichtung aufweist. Die Bestrahlungsphantomvorrichtung ist zumindest bereichsweise mit bestrahlungsphantomvorbildkonformen Bestrahlungseigenschaften versehen
    • …
    corecore