12 research outputs found

    Improving the utilization of implantable cardioverter defibrillators for sudden cardiac arrest prevention Improve SCA in developing countries Clinical characteristics and reasons for implantation refusal.

    No full text
    9 páginasBACKGROUND: Despite available evidence that implantable cardioverter defibrillators (ICDs) reduce all-cause mortality among patients at risk for sudden cardiac death, utilization of ICDs is low especially in developing countries. OBJECTIVE: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries. METHODS: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction < 25%, nonsustained ventricular tachycardia [NSVT], or frequent premature ventricular complexes) were further categorized as "1.5 PP patients." Candidates who declined implantation were asked for reasons for refusal. Baseline factors that may have influenced the implant decision were examined using logistic regression. RESULTS: Among 3892 patients, the implant refusal rate was 46.5% among PP patients (n = 2700), and 10.3% among SP patients (n = 1192). The most common refusal reason was inability to pay for the device (53.8%), followed by not believing in the benefits of the ICD (19.4%). Among PP ICD candidates, those with no syncope, no NSVT, no premature ventricular contractions, shorter QRS duration, no atrial arrhythmias, and no left bundle branch block were more likely to refuse implant. Among SP candidates, a history of cardiovascular surgery and no sinus node dysfunction were significant predictors of ICD refusal. Additionally, countries had significant differences in patient refusal rates among PP and SP groups. CONCLUSION: Implant refusal among PP patients is high in many countries. Increased reimbursement and better awareness of the benefits of an ICD could increase their utilization

    Cardioverter-defibrillator reduces mortality risk in eligible ischemic and non-ischemic cardiomyopathy patients: Sub-analysis of the multi-center Improve SCA study

    No full text
    Background &amp; Objective: Despite the burden of sudden cardiac arrest (SCA) worldwide, implantable cardioverter-defibrillators (ICDs) are underutilized, particularly in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA trial demonstrated that primary prevention (PP) patients in these regions benefit from an ICD or a cardiac resynchronization therapy defibrillator (CRT-D). We aimed to compare the rate of device therapy and mortality among ischemic and non-ischemic cardiomyopathy (ICM and NICM) PP patients who met guideline indications for ICD therapy and had an ICD/CRT-D implanted. Methods: Improve SCA was a prospective, non-randomized, non-blinded multicenter trial that enrolled patients from the above-mentioned regions. All-cause mortality and device therapy were examined by cardiomyopathy (ICM vs NICM) and implantation status. Cox proportional hazards methods were used, adjusting for factors affecting mortality risk. Results: Of 1848 PP NICM patients, 1007 (54.5%) received ICD/CRT-D, while 303 of 581 (52.1%) PP ICM patients received an ICD/CRT-D. The all-cause mortality rate at 3 years for NICM patients with and without an ICD/CRT-D was 13.1% and 18.3%, respectively (HR 0.51, 95% CI 0.38–0.68, p < 0.001). Similarly, all-cause mortality at 3 years in ICM patients was 13.8% in those with a device and 19.9% in those without an ICD/CRT-D (HR 0.54, 95% CI 0.33–.0.88, p = 0.011). The time to first device therapy, time to first shock, and time to first antitachycardia pacing (ATP) therapy were not significantly different between groups (p ≥ 0.263). Conclusions: In this large data set of patients with a guideline-based PP ICD indication, defibrillator device implantation conferred a significant mortality benefit in both NICM and ICM patients. The rate of appropriate device therapy was also similar in both groups. Clinical trial registration: ClinicalTrials.gov ID: NCT02099721

    Atrial fibrillation history impact on catheter ablation outcome. Findings from the ESC-EHRA Atrial Fibrillation Ablation Long-Term Registry

    No full text
    Background Atrial fibrillation (AF) promotes atrial remodeling that in turn promotes AF perpetuation. The aim of our study is to investigate the impact of AF history length on 1-year outcome of AF catheter ablation in a cohort of patients enrolled in the Atrial Fibrillation Ablation Registry. Methods We described the real-life clinical epidemiology, therapeutic strategies, and the short- and mid-term outcomes of 1948 patients (71.9% with paroxysmal AF) undergoing AF ablation procedures, stratified according to AF history duration (= 2 years). Results The mean AF history duration was 46.2 +/- 57.4 months, 592 patients had an AF history duration = 2 years (mean 75.5 +/- 63.5 months) (P = 2 years (34.0%) (P = 0.037). AF history duration >= 2 years, overall ablation procedure duration, hypertension, and chronic kidney disease were all predictors of recurrences after the blanking period. Conclusions In this multicenter registry, performing catheter ablation in patients with an AF history >= 2 years was associated with higher rates of AF recurrences at 1 year. Since cumulative time in AF in not necessarily equivalent to AF history, its role remains to be clarified.Cardiolog

    2019 ESC Guidelines for the management of patients with supraventricular tachycardiaThe Task Force for the management of patients with supraventricular tachycardia of the European Society of Cardiology (ESC).

    Get PDF
    [No abstract available

    2019 ESC Guidelines for themanagement of patients with supraventricular tachycardia

    No full text

    2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS): 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS)

    Get PDF
    © 2020 European Society of Cardiology. All rights reserved.Atrial fibrillation (AF) poses significant burden to patients, physicians, and healthcare systems globally. Substantial research efforts and resources are being directed towards gaining detailed information about the mechanisms underlying AF, its natural course and effective treatments (see also the ESC Textbook of Cardiovascular Medicine: CardioMed) and new evidence is continuously generated and published. The complexity of AF requires a multifaceted, holistic, and multidisciplinary approach to the management of AF patients, with their active involvement in partnership with clinicians. Streamlining the care of patients with AF in daily clinical practice is a challenging but essential requirement for effective management of AF. In recent years, substantial progress has been made in the detection of AF and its management, and new evidence is timely integrated in this third edition of the ESC guidelines on AF. The 2016 ESC AF Guidelines introduced the concept of the five domains to facilitate an integrated structured approach to AF care and promote consistent, guideline-adherent management for all patients. The Atrial Fibrillation Better Care (ABC) approach in the 2020 ESC AF Guidelines is a continuum of this approach, with the goal to further improve the structured management of AF patients, promote patient values, and finally improve patient outcomes.info:eu-repo/semantics/publishedVersio
    corecore