16 research outputs found

    Ground Truth Simulation for Deep Learning Classification of Mid-Resolution Venus Images Via Unmixing of High-Resolution Hyperspectral Fenix Data

    Full text link
    Training a deep neural network for classification constitutes a major problem in remote sensing due to the lack of adequate field data. Acquiring high-resolution ground truth (GT) by human interpretation is both cost-ineffective and inconsistent. We propose, instead, to utilize high-resolution, hyperspectral images for solving this problem, by unmixing these images to obtain reliable GT for training a deep network. Specifically, we simulate GT from high-resolution, hyperspectral FENIX images, and use it for training a convolutional neural network (CNN) for pixel-based classification. We show how the model can be transferred successfully to classify new mid-resolution VENuS imagery

    High-performance infrared photodetectors based on InAs/InAsSb/AlAsSb superlattice for 3.5 µm cutoff wavelength spectra

    Get PDF
    High-performance infrared p-i-n photodetectors based on InAs/InAsSb/AlAsSb superlattices on GaSb substrate have been demonstrated at 300K. These photodetectors exhibit 50% and 100% cut-off wavelength of ∼3.2 µm and ∼3.5 µm, respectively. Under -130 mV bias voltage, the device exhibits a peak responsivity of 0.56 A/W, corresponding to a quantum efficiency (QE) of 28%. The dark current density at 0 mV and -130 mV bias voltage are 8.17 × 10−2 A/cm2 and 5.02 × 10−1 A/cm2, respectively. The device exhibits a saturated dark current shot noise limited specific detectivity (D*) of 3.43 × 109 cm·Hz1/2/W (at a peak responsivity of 2.5 µm) under -130 mV of applied bias

    Experimental Study of Flow-Induced Whistling in Pipe Systems Including a Corrugated Section

    No full text
    When air flows through pipe systems that include a corrugated segment, a whistling tone is generated and increases in intensity with increasing flow velocity. This whistling sound is related to the particular geometry of corrugated pipes, which is in the form of alternating cavities. This whistling is an environmental noise problem as well as a possible structural danger because of the resulting induced vibration. This paper studies the whistling behavior of various pipe systems with a combination of smooth and corrugated pipes through a series of experiments. The considered pipe systems consist of two smooth pipes attached at the upstream and downstream ends of a corrugated segment. Experiments with smooth and corrugated pipes, which had inner diameters of 15.25 and 16.5 mm, respectively, and various lengths, were performed for flow velocities of up to approximately 30 m/s. The minimum and maximum Strouhal numbers (St) obtained during our experiments were 0.25 and 0.38, respectively. For all pipe configurations investigated in this study, the lowest Mach number at which whistling was observed was 0.017, and the maximum was 0.093. The lowest frequency at which whistling was detected in our experiments was 650 Hz, and the highest was 3080 Hz. The results presented in the form of different variables and dimensionless parameters, including the frequency, Mach number, Strouhal number, and Helmholtz number. The average mode gap and number of excited acoustic modes were also taken into account for all considered configurations. The pipe systems with longer corrugated segments had broader whistling ranges than did configurations with shorter segments, indicating that the number of cavities inside the corrugated pipe has a direct effect on whistling. Increasing the smooth pipe length (either upstream or downstream) resulted in a decrease in the average mode gap between successive modes. The number of excited acoustic modes was primarily related to the corrugated segment length, but the smooth pipe length also had a pronounced effect on the excited modes for a constant corrugation length. The highest number of excited modes (13) was seen in the case of corrugated length 450 mm and smooth pipe length (either upstream or downstream) 400 mm while the lowest number of excited modes (1) was observed for corrugated length 250 mm and smooth pipe length (downstream) 300 mm and 400 mm
    corecore