721 research outputs found

    The new paradigm of hepatitis C therapy: integration of oral therapies into best practices.

    Get PDF
    Emerging data indicate that all-oral antiviral treatments for chronic hepatitis C virus (HCV) will become a reality in the near future. In replacing interferon-based therapies, all-oral regimens are expected to be more tolerable, more effective, shorter in duration and simpler to administer. Coinciding with new treatment options are novel methodologies for disease screening and staging, which create the possibility of more timely care and treatment. Assessments of histologic damage typically are performed using liver biopsy, yet noninvasive assessments of histologic damage have become the norm in some European countries and are becoming more widespread in the United States. Also in place are new Centers for Disease Control and Prevention (CDC) initiatives to simplify testing, improve provider and patient awareness and expand recommendations for HCV screening beyond risk-based strategies. Issued in 2012, the CDC recommendations aim to increase HCV testing among those with the greatest HCV burden in the United States by recommending one-time testing for all persons born during 1945-1965. In 2013, the United States Preventive Services Task Force adopted similar recommendations for risk-based and birth-cohort-based testing. Taken together, the developments in screening, diagnosis and treatment will likely increase demand for therapy and stimulate a shift in delivery of care related to chronic HCV, with increased involvement of primary care and infectious disease specialists. Yet even in this new era of therapy, barriers to curing patients of HCV will exist. Overcoming such barriers will require novel, integrative strategies and investment of resources at local, regional and national levels

    The Nearby Supernova Factory

    Get PDF
    The Nearby Supernova Factory (SNfactory) is an ambitious project to find and study in detail approximately 300 nearby Type Ia supernovae (SNe~Ia) at redshifts 0.03<z<0.08. This program will provide an exceptional data set of well-studied SNe in the nearby smooth Hubble flow that can be used as calibration for the current and future programs designed to use SNe to measure the cosmological parameters. The first key ingredient for this program is a reliable supply of Hubble-flow SNe systematically discovered in unprecedented numbers using the same techniques as those used in distant SNe searches. In 2002, 35 SNe were found using our test-bed pipeline for automated SN search and discovery. The pipeline uses images from the asteroid search conducted by the Near Earth Asteroid Tracking group at JPL. Improvements in our subtraction techniques and analysis have allowed us to increase our effective SN discovery rate to ~12 SNe/month in 2003.Comment: 7 pages, 3 figures to be published in New Astronomy Review

    EASL Clinical Practice Guidelines on non-invasive tests for evaluation of liver disease severity and prognosis – 2021 update

    Get PDF
    Non-invasive tests are increasingly being used to improve the diagnosis and prognostication of chronic liver diseases across aetiologies. Herein, we provide the latest update to the EASL Clinical Practice Guidelines on the use of non-invasive tests for the evaluation of liver disease severity and prognosis, focusing on the topics for which relevant evidence has been published in the last 5 years

    The Drift Chambers Of The Nomad Experiment

    Get PDF
    We present a detailed description of the drift chambers used as an active target and a tracking device in the NOMAD experiment at CERN. The main characteristics of these chambers are a large area, a self supporting structure made of light composite materials and a low cost. A spatial resolution of 150 microns has been achieved with a single hit efficiency of 97%.Comment: 42 pages, 26 figure

    Applicability and precautions of use of liver injury biomarker FibroTest. A reappraisal at 7 years of age

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>FibroTest (FT) is a validated biomarker of fibrosis. To assess the applicability rate and to reduce the risk of false positives/negatives (RFPN), security algorithms were developed. The aims were to estimate the prevalence of RFPN and of proven failures, and to identify factors associated with their occurrences.</p> <p>Methods</p> <p>Four populations were studied: 954 blood donors (P1), 7,494 healthy volunteers (P2), 345,695 consecutive worldwide sera (P3), including 24,872 sera analyzed in a tertiary care centre (GHPS) (P4). Analytical procedures of laboratories with RFPN > 5% and charts of P4 patients in with RFPN were reviewed.</p> <p>Results</p> <p>The prevalence of RFPN was 0.52% (5/954; 95%CI 0.17-1.22) in P1, 0.51% (38/7494; 0.36-0.70) in P2, and 0.97% (3349/345695; 0.94-1.00) in P3. Three a priori high-risk populations were confirmed: 1.97% in P4, 1.77% in HIV centre and 2.61% in Sub-Saharan origin subjects. RFPN was mostly associated with low haptoglobin (0.46%), and high apolipoproteinA1 (0.21%). A traceability study of a P3 laboratory with RFPFN > 5% permitted to correct analytical procedures.</p> <p>Conclusion</p> <p>The mean applicability rate of Fibrotest was 99.03%. Independent factors associated with the high risk of false positives/negatives were HIV center, subSaharan origin, and a tertiary care reference centre, although the applicability rate remained above 97%.</p

    Liver Stiffness Measurement and Biochemical Markers in Senegalese Chronic Hepatitis B Patients with Normal ALT and High Viral Load

    Get PDF
    Despite the high prevalence of chronic hepatitis B (CHB) in Africa, few studies have been performed among African patients. We sought to evaluate liver stiffness measurement by FibroScan® (LSM) and two biochemical scores (FibroTest®, Fibrometer®) to diagnose liver fibrosis in Senegalese CHB patients with HBV plasma DNA load ≥3.2 log(10) IU/mL and normal alanine aminotransferase (ALT) values.LSM and liver fibrosis biochemical markers were performed on 225 consecutive HBV infected Senegalese patients with high viral load. Patients with an LSM range between 7 and 13 kPa underwent liver biopsy (LB). Two experienced liver pathologists performed histological grading using Metavir and Ishak scoring.225 patients were evaluated (84% male) and LB was performed in 69 patients, showing F2 and F3 fibrosis in 17% and 10% respectively. In these patients with a 7-13 kPa range of LSM, accuracy for diagnosis of significant fibrosis according to LB was unsatisfactory for all non-invasive markers with AUROCs below 0.70. For patients with LSM values below 7 kPa, FibroTest® (FT), and Fibrometer® (FM) using the cut-offs recommended by the test promoters suggested a fibrosis in 18% of cases for FT (8% severe fibrosis) and 8% for FM. For patients with LSM values greater than 13 kPa, FT, FM suggested a possible fibrosis in 73% and 70%, respectively.In highly replicative HBV-infected African patients with normal ALT and LSM value below 13 kPa, FibroScan®, FibroTest® or Fibrometer® were unsuitable to predict the histological liver status of fibrosis
    corecore