627 research outputs found

    A search for energy deposition by neutrinos in matter

    Get PDF
    An exploratory search for an anomalous energy deposition by neutrinos in a germanium crystal was performed in the CERN high energy neutrino beam. No signal was found and a limit is set at a level of about 10^-12 of the normal dE/dx for a minimum ionizing particle.Comment: 7 pages, 3 figures Paper accepted by Physics Letters B on March 4th, 199

    The Nearby Supernova Factory

    Get PDF
    The Nearby Supernova Factory (SNfactory) is an ambitious project to find and study in detail approximately 300 nearby Type Ia supernovae (SNe~Ia) at redshifts 0.03<z<0.08. This program will provide an exceptional data set of well-studied SNe in the nearby smooth Hubble flow that can be used as calibration for the current and future programs designed to use SNe to measure the cosmological parameters. The first key ingredient for this program is a reliable supply of Hubble-flow SNe systematically discovered in unprecedented numbers using the same techniques as those used in distant SNe searches. In 2002, 35 SNe were found using our test-bed pipeline for automated SN search and discovery. The pipeline uses images from the asteroid search conducted by the Near Earth Asteroid Tracking group at JPL. Improvements in our subtraction techniques and analysis have allowed us to increase our effective SN discovery rate to ~12 SNe/month in 2003.Comment: 7 pages, 3 figures to be published in New Astronomy Review

    The Drift Chambers Of The Nomad Experiment

    Get PDF
    We present a detailed description of the drift chambers used as an active target and a tracking device in the NOMAD experiment at CERN. The main characteristics of these chambers are a large area, a self supporting structure made of light composite materials and a low cost. A spatial resolution of 150 microns has been achieved with a single hit efficiency of 97%.Comment: 42 pages, 26 figure

    EASL Clinical Practice Guidelines on non-invasive tests for evaluation of liver disease severity and prognosis – 2021 update

    Get PDF
    Non-invasive tests are increasingly being used to improve the diagnosis and prognostication of chronic liver diseases across aetiologies. Herein, we provide the latest update to the EASL Clinical Practice Guidelines on the use of non-invasive tests for the evaluation of liver disease severity and prognosis, focusing on the topics for which relevant evidence has been published in the last 5 years

    Liver Stiffness Measurement and Biochemical Markers in Senegalese Chronic Hepatitis B Patients with Normal ALT and High Viral Load

    Get PDF
    Despite the high prevalence of chronic hepatitis B (CHB) in Africa, few studies have been performed among African patients. We sought to evaluate liver stiffness measurement by FibroScan® (LSM) and two biochemical scores (FibroTest®, Fibrometer®) to diagnose liver fibrosis in Senegalese CHB patients with HBV plasma DNA load ≥3.2 log(10) IU/mL and normal alanine aminotransferase (ALT) values.LSM and liver fibrosis biochemical markers were performed on 225 consecutive HBV infected Senegalese patients with high viral load. Patients with an LSM range between 7 and 13 kPa underwent liver biopsy (LB). Two experienced liver pathologists performed histological grading using Metavir and Ishak scoring.225 patients were evaluated (84% male) and LB was performed in 69 patients, showing F2 and F3 fibrosis in 17% and 10% respectively. In these patients with a 7-13 kPa range of LSM, accuracy for diagnosis of significant fibrosis according to LB was unsatisfactory for all non-invasive markers with AUROCs below 0.70. For patients with LSM values below 7 kPa, FibroTest® (FT), and Fibrometer® (FM) using the cut-offs recommended by the test promoters suggested a fibrosis in 18% of cases for FT (8% severe fibrosis) and 8% for FM. For patients with LSM values greater than 13 kPa, FT, FM suggested a possible fibrosis in 73% and 70%, respectively.In highly replicative HBV-infected African patients with normal ALT and LSM value below 13 kPa, FibroScan®, FibroTest® or Fibrometer® were unsuitable to predict the histological liver status of fibrosis

    The use of transient elastography in the management of chronic hepatitis B

    Get PDF
    There has been increasing interest in noninvasive methods of assessing liver fibrosis over the last decade. The use of transient elastography in measuring liver stiffness has become the forefront of a wide range of noninvasive tools. Most of the other methods are based on measurements of biomarkers associated with fibrosis. There are several reasons for its wide acceptance, including the ease of performing a scan, the short procedure time, the results being immediately available on completion of the examination, and its reproducibility. For chronic hepatitis B (CHB), the cut-off values for F3 and F4 fibrosis range between 7.5–12.0 and 11.0–13.4 kPa, respectively, although the cut-offs may be slightly lower in those with normal ALT. In addition to measuring liver fibrosis, recent studies have demonstrated several other roles for transient elastography, including selecting patients who will benefit from antiviral therapy, monitoring response to antiviral therapy, and predicting long-term outcomes. However, there are limitations associated with transient elastography, including the confounding effects of inflammatory activity, and to a lesser extent, steatosis, on liver stiffness. There is also reduced accuracy observed in lower fibrosis stages (F0–F2). Furthermore, the incidences of failed and unreliable scan have been reported to be ~ 3 and 16%, respectively. Although liver biopsy can be avoided in an estimated 50–60% using transient elastography, in situations where liver stiffness measurement is nondiagnostic or inconsistent with the clinical picture, a biopsy is still recommended. Further studies are needed to consolidate the role of transient elastography in the management of CHB, and for incorporation of this method into current treatment guidelines

    Applicability and precautions of use of liver injury biomarker FibroTest. A reappraisal at 7 years of age

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>FibroTest (FT) is a validated biomarker of fibrosis. To assess the applicability rate and to reduce the risk of false positives/negatives (RFPN), security algorithms were developed. The aims were to estimate the prevalence of RFPN and of proven failures, and to identify factors associated with their occurrences.</p> <p>Methods</p> <p>Four populations were studied: 954 blood donors (P1), 7,494 healthy volunteers (P2), 345,695 consecutive worldwide sera (P3), including 24,872 sera analyzed in a tertiary care centre (GHPS) (P4). Analytical procedures of laboratories with RFPN > 5% and charts of P4 patients in with RFPN were reviewed.</p> <p>Results</p> <p>The prevalence of RFPN was 0.52% (5/954; 95%CI 0.17-1.22) in P1, 0.51% (38/7494; 0.36-0.70) in P2, and 0.97% (3349/345695; 0.94-1.00) in P3. Three a priori high-risk populations were confirmed: 1.97% in P4, 1.77% in HIV centre and 2.61% in Sub-Saharan origin subjects. RFPN was mostly associated with low haptoglobin (0.46%), and high apolipoproteinA1 (0.21%). A traceability study of a P3 laboratory with RFPFN > 5% permitted to correct analytical procedures.</p> <p>Conclusion</p> <p>The mean applicability rate of Fibrotest was 99.03%. Independent factors associated with the high risk of false positives/negatives were HIV center, subSaharan origin, and a tertiary care reference centre, although the applicability rate remained above 97%.</p
    corecore