9 research outputs found

    Periodicities in the Daily Proton Fluxes from 2011 to 2019 Measured by the Alpha Magnetic Spectrometer on the International Space Station from 1 to 100 GV

    Get PDF
    We present the precision measurement of the daily proton fluxes in cosmic rays from May 20, 2011 to October 29, 2019 (a total of 2824 days or 114 Bartels rotations) in the rigidity interval from 1 to 100 GV based on 5.5×109 protons collected with the Alpha Magnetic Spectrometer aboard the International Space Station. The proton fluxes exhibit variations on multiple timescales. From 2014 to 2018, we observed recurrent flux variations with a period of 27 days. Shorter periods of 9 days and 13.5 days are observed in 2016. The strength of all three periodicities changes with time and rigidity. The rigidity dependence of the 27-day periodicity is different from the rigidity dependences of 9-day and 13.5-day periods. Unexpectedly, the strength of 9-day and 13.5-day periodicities increases with increasing rigidities up to ∼10 GV and ∼20 GV, respectively. Then the strength of the periodicities decreases with increasing rigidity up to 100 GV.</p

    Cardiovascular risk management in patients with coronary heart disease in primary care: variation across countries and practices. An observational study based on quality indicators

    Get PDF
    Contains fulltext : 110491.pdf (publisher's version ) (Open Access)ABSTRACT: BACKGROUND: Primary care has an important role in cardiovascular risk management (CVRM) and a minimum size of scale of primary care practices may be needed for efficient delivery of CVRM . We examined CVRM in patients with coronary heart disease (CHD) in primary care and explored the impact of practice size. METHODS: In an observational study in 8 countries we sampled CHD patients in primary care practices and collected data from electronic patient records. Practice samples were stratified according to practice size and urbanisation; patients were selected using coded diagnoses when available. CVRM was measured on the basis of internationally validated quality indicators. In the analyses practice size was defined in terms of number of patients registered of visiting the practice. We performed multilevel regression analyses controlling for patient age and sex. RESULTS: We included 181 practices (63% of the number targeted). Two countries included a convenience sample of practices. Data from 2960 CHD patients were available. Some countries used methods supplemental to coded diagnoses or other inclusion methods introducing potential inclusion bias. We found substantial variation on all CVRM indicators across practices and countries. We computed aggregated practice scores as percentage of patients with a positive outcome. Rates of risk factor recording varied from 55% for physical activity as the mean practice score across all practices (sd 32%) to 94% (sd 10%) for blood pressure. Rates for reaching treatment targets for systolic blood pressure, diastolic blood pressure and LDL cholesterol were 46% (sd 21%), 86% (sd 12%) and 48% (sd 22%) respectively. Rates for providing recommended cholesterol lowering and antiplatelet drugs were around 80%, and 70% received influenza vaccination. Practice size was not associated to indicator scores with one exception: in Slovenia larger practices performed better. Variation was more related to differences between practices than between countries. CONCLUSIONS: CVRM measured by quality indicators showed wide variation within and between countries and possibly leaves room for improvement in all countries involved. Few associations of performance scores with practice size were found

    Properties of Cosmic Helium Isotopes Measured by the Alpha Magnetic Spectrometer

    No full text
    Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of He3 and He4 fluxes are presented. The measurements are based on 100 million He4 nuclei in the rigidity range from 2.1 to 21 GV and 18 million He3 from 1.9 to 15 GV collected from May 2011 to November 2017. We observed that the He3 and He4 fluxes exhibit nearly identical variations with time. The relative magnitude of the variations decreases with increasing rigidity. The rigidity dependence of the He3/He4 flux ratio is measured for the first time. Below 4 GV, the He3/He4 flux ratio was found to have a significant long-term time dependence. Above 4 GV, the He3/He4 flux ratio was found to be time independent, and its rigidity dependence is well described by a single power law 08R\u394 with \u394=-0.294\ub10.004. Unexpectedly, this value is in agreement with the B/O and B/C spectral indices at high energies

    Towards Understanding the Origin of Cosmic-Ray Electrons

    No full text
    Precision results on cosmic-ray electrons are presented in the energy range from 0.5 GeV to 1.4 TeV based on 28.1 7106 electrons collected by the Alpha Magnetic Spectrometer on the International Space Station. In the entire energy range the electron and positron spectra have distinctly different magnitudes and energy dependences. The electron flux exhibits a significant excess starting from 42.1-5.2+5.4 GeV compared to the lower energy trends, but the nature of this excess is different from the positron flux excess above 25.2\ub11.8 GeV. Contrary to the positron flux, which has an exponential energy cutoff of 810-180+310 GeV, at the 5\u3c3 level the electron flux does not have an energy cutoff below 1.9 TeV. In the entire energy range the electron flux is well described by the sum of two power law components. The different behavior of the cosmic-ray electrons and positrons measured by the Alpha Magnetic Spectrometer is clear evidence that most high energy electrons originate from different sources than high energy positrons

    Temporal Structures in Electron Spectra and Charge Sign Effects in Galactic Cosmic Rays

    No full text
    International audienceWe present the precision measurements of 11 years of daily cosmic electron fluxes in the rigidity interval from 1.00 to 41.9 GV based on 2.0×108 electrons collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The electron fluxes exhibit variations on multiple timescales. Recurrent electron flux variations with periods of 27 days, 13.5 days, and 9 days are observed. We find that the electron fluxes show distinctly different time variations from the proton fluxes. Remarkably, a hysteresis between the electron flux and the proton flux is observed with a significance of greater than 6σ at rigidities below 8.5 GV. Furthermore, significant structures in the electron-proton hysteresis are observed corresponding to sharp structures in both fluxes. This continuous daily electron data provide unique input to the understanding of the charge sign dependence of cosmic rays over an 11-year solar cycle

    Properties of Cosmic-Ray Sulfur and Determination of the Composition of Primary Cosmic-Ray Carbon, Neon, Magnesium, and Sulfur: Ten-Year Results from the Alpha Magnetic Spectrometer

    No full text
    International audienceWe report the properties of primary cosmic-ray sulfur (S) in the rigidity range 2.15 GV to 3.0 TV based on 0.38×106 sulfur nuclei collected by the Alpha Magnetic Spectrometer experiment (AMS). We observed that above 90 GV the rigidity dependence of the S flux is identical to the rigidity dependence of Ne-Mg-Si fluxes, which is different from the rigidity dependence of the He-C-O-Fe fluxes. We found that, similar to N, Na, and Al cosmic rays, over the entire rigidity range, the traditional primary cosmic rays S, Ne, Mg, and C all have sizeable secondary components, and the S, Ne, and Mg fluxes are well described by the weighted sum of the primary silicon flux and the secondary fluorine flux, and the C flux is well described by the weighted sum of the primary oxygen flux and the secondary boron flux. The primary and secondary contributions of the traditional primary cosmic-ray fluxes of C, Ne, Mg, and S (even Z elements) are distinctly different from the primary and secondary contributions of the N, Na, and Al (odd Z elements) fluxes. The abundance ratio at the source for S/Si is 0.167±0.006, for Ne/Si is 0.833±0.025, for Mg/Si is 0.994±0.029, and for C/O is 0.836±0.025. These values are determined independent of cosmic-ray propagation
    corecore