10 research outputs found

    In Vitro Cytotoxicity of GuttaFlow Bioseal, GuttaFlow 2, AH-Plus and MTA Fillapex

    Get PDF
    Introduction: The aim of the present in vitro study was to evaluate the cytotoxicity of different sealers including GuttaFlow Bioseal, GuttaFlow 2, AH-Plus and MTA Fillapex on L929 murine fibroblasts. Methods and Materials: Samples of GuttaFlow Bioseal, GuttaFlow 2, AH-Plus and MTA Fillapex were fabricated in Teflon disks of 5 mm diameter and 3 mm thickness. L929 fibroblasts were exposed to the extracts of these materials for 3, 24, 72 and 168 h at 37°C with 5% CO2. Cell viability was evaluated by the 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) assay. Apoptosis was evaluated by the terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay. The data were analysed by ANOVA. Results: GuttaFlow Bioseal was nontoxic at all experimental time points (P>0.05), whereas MTA Fillapex and AH-Plus were toxic (P<0.001). At 7 days, there were more viable cells in the GuttaFlow 2 group than in the control group, and MTA Fillapex was more cytotoxic than AH-Plus. There were more apoptotic cells in the MTA Fillapex and AH-Plus groups than in the other groups at 3 h (P<0.001). Conclusion: GuttaFlow sealers are less cytotoxic than MTA Fillapex and AH-Plus. At all experimental time points, there was no significant difference in the cell viability between the GuttaFlow Bioseal group and the control group.Keywords: AH-Plus; Cytotoxicity; GuttaFlow Bioseal; GuttaFlow 2; MTA Fillapex; MTT Assay; TUNEL Assa

    Single-Visit Pulp Revascularization of a Nonvital Immature Permanent Tooth Using Biodentine

    Get PDF
    An 11-year-old female patient was referred with a chief complaint of pain in the right mandibular second premolar. Clinical and radiographic examinations showed secondary caries under an old composite restoration, a negative response to a pulp test and an immature root with an open apex. After root canal cleaning and shaping, bleeding was invoked in the canal up to 2 mm short of the cemento-enamel junction (CEJ). After 10 min to allow clotting at this level, a plug of Biodentine was placed over the blood clot and the tooth was temporized with glass ionomer cement. At the next visit, the tooth was free of symptoms and a permanent filling was placed. Clinical and radiographic examinations during a two-year follow-up showed complete root maturation and intact supporting soft tissues without sinus tract, pain or swelling. Conclusion: The use of Biodentine in a single-visit apexification protocol to treat an immature permanent tooth with necrotic pulp can create a suitable environment for revascularization, resulting in the completion of root maturation.Key Words:Biodentine; Immature Apex; Pulp Revascularization

    Comparison of the Cyclic Fatigue Resistance of 5 Different Rotary Pathfinding Instruments Made of Conventional Nickel-Titanium Wire, M-wire, and Controlled Memory Wire

    No full text
    WOS: 000353076700019PubMed ID: 25510316Introduction: This study compared the cyclic fatigue resistance of current nickel-titanium rotary path-finding instruments. Methods: Five types of nickel-titanium rotary pathfinding instruments were used in steel canals with a 90 degrees curvature and a curvature radius of 3 mm (n = 10) and 5 mm (n = 10). The cyclic fatigue of the following instruments was tested at 4 mm from the tip: PathFile (#16 and a .02 taper; Dentsply Maillefer, Ballaigues, Switzerland), G-File (#12 and a .03 taper; Micro-Mega, Besancon Cedex, France), Scout Race (#15 and a .02 taper; FKG Dentaire, La Chaux-de-Fonds, Switzerland), HyFlex GPF (#15 and a .02 taper; Coltene-Whaledent, Allstetten, Switzerland), and ProGlider (#16 with a mean taper of .04125 and a .02 at the first 4 mm from the tip, Dentsply Maillefer). The length of the fractured parts was measured, and the number of cycles to fracture (NCF) was calculated. The data were statistically analyzed using Kruskal-Wallis and MannWhitney tests (alpha =.05). After Bonferroni correction, the new P value was set as .005. Results: The difference in the cyclic fatigue of all the files at both curvatures was statistically significant (P values from .0035 to less than .0001). The ranking of the instruments from the highest to the lowest NCF was as follows: HyFlex GPF, G files, ProGlider, PathFile, and Scout Race. The length of the fractured part of the instruments was similar in all the groups > .05). All the tested instruments had a lower NCF at a curvature radius of 3 mm when compared with a curvature radius of 5 mm (P < .0001). Conclusions: Within the limitations of this study, the cyclic fatigue resistance of the HyFlex GPF instrument was the highest, and the curvature radius had a significant effect on the fatigue resistance
    corecore