102 research outputs found
Changes in smell and taste perception related to COVID-19 infection: a case–control study
The main aim of the present study was to psychophysically evaluate smell and taste functions in hospitalized COVID‐19 patients and to compare those results with a group of healthy subjects. Another aim of the study was to assess the relationship of changes in patients’ smell and taste functions with a number of clinical parameters, symptoms, and other physiological signs as well as with severity of disease. Olfactory and gustatory functions were tested in 61 hospitalized patients positive for SARS‐CoV‐2 infection and in a control group of 54 healthy individuals. Overall, we found a significant impairment of olfactory and gustatory functions in COVID‐19 patients compared with the control group. Indeed, about 45% of patients self‐reported complaints about or loss of either olfactory or gustatory functions. These results were confirmed by psychophysical testing, which showed a significantly reduced performance in terms of intensity perception and identification ability for both taste and smell functions in COVID‐19 patients. Furthermore, gustatory and olfactory impairments tended to be more evident in male patients suffering from more severe respiratory failure (i.e., pneumonia with need of respiratory support need during hospitalization)
A medical device-grade T1 and ECV phantom for global T1 mapping quality assurance - the T Mapping and ECV Standardization in cardiovascular magnetic resonance (T1MES) program
T mapping and extracellular volume (ECV) have the potential to guide patient care and serve as surrogate end-points in clinical trials, but measurements differ between cardiovascular magnetic resonance (CMR) scanners and pulse sequences. To help deliver T mapping to global clinical care, we developed a phantom-based quality assurance (QA) system for verification of measurement stability over time at individual sites, with further aims of generalization of results across sites, vendor systems, software versions and imaging sequences. We thus created T1MES: The T1 Mapping and ECV Standardization Program.
A design collaboration consisting of a specialist MRI small-medium enterprise, clinicians, physicists and national metrology institutes was formed. A phantom was designed covering clinically relevant ranges of T and T in blood and myocardium, pre and post-contrast, for 1.5 T and 3 T. Reproducible mass manufacture was established. The device received regulatory clearance by the Food and Drug Administration (FDA) and Conformité Européene (CE) marking.
The T1MES phantom is an agarose gel-based phantom using nickel chloride as the paramagnetic relaxation modifier. It was reproducibly specified and mass-produced with a rigorously repeatable process. Each phantom contains nine differently-doped agarose gel tubes embedded in a gel/beads matrix. Phantoms were free of air bubbles and susceptibility artifacts at both field strengths and T maps were free from off-resonance artifacts. The incorporation of high-density polyethylene beads in the main gel fill was effective at flattening the field. T and T values measured in T1MES showed coefficients of variation of 1 % or less between repeat scans indicating good short-term reproducibility. Temperature dependency experiments confirmed that over the range 15-30 °C the short-T tubes were more stable with temperature than the long-T tubes. A batch of 69 phantoms was mass-produced with random sampling of ten of these showing coefficients of variations for T of 0.64 ± 0.45 % and 0.49 ± 0.34 % at 1.5 T and 3 T respectively.
The T1MES program has developed a T mapping phantom to CE/FDA manufacturing standards. An initial 69 phantoms with a multi-vendor user manual are now being scanned fortnightly in centers worldwide. Future results will explore T mapping sequences, platform performance, stability and the potential for standardization.This project has been funded by a European Association of Cardiovascular Imaging (EACVI part of the ESC) Imaging Research Grant, a UK National Institute of Health Research (NIHR) Biomedical Research Center (BRC) Cardiometabolic Research Grant at University College London (UCL, #BRC/ 199/JM/101320), and a Barts Charity Research Grant (#1107/2356/MRC0140). G.C. is supported by the National Institute for Health Research Rare Diseases Translational Research Collaboration (NIHR RD-TRC) and by the NIHR UCL Hospitals Biomedical Research Center. J.C.M. is directly and indirectly supported by the UCL Hospitals NIHR BRC and Biomedical Research Unit at Barts Hospital respectively. This work was in part supported by an NIHR BRC award to Cambridge University Hospitals NHS Foundation Trust and NIHR Cardiovascular Biomedical Research Unit support at Royal Brompton Hospital London UK
Current trends and challenges in the clinical use of cardiovascular magnetic resonance: a survey from the Italian Society of Cardiology
Aims: Challenges related to the use of cardiovascular magnetic resonance (CMR) remain a key issue to secure its full clinical impact. This survey aimed to assess the awareness of CMR clinical utility and to collect data on its local usage levels, operational barriers, and report efficacy, with the goal of identifying key obstacles to its effective implementation across Italy. Methods and results: The CMR Working Group of the Italian Society of Cardiology promoted an online survey targeting Italian physicians involved in direct care of patients with cardiovascular disease. The questionnaire was completed by 709 physicians, mostly working in public or university hospitals (75%); 27% were medical residents. Cardiomyopathies and myocarditis were identified as the most established clinical indications for CMR. 79% of respondents perceived underutilisation of CMR in their local settings, with waiting times exceeding 3 months in 42% of cases. Public hospitals were reported as the primary providers of CMR services (41%), with the majority of CMR reports signed exclusively by radiologists. Obstacles in obtaining clinically useful and effective CMR exams were frequent, with 69% of respondents often encountering issues. Need for an expert second opinion was reported by 27% of participants either often or always. Stress CMR was reported of limited access or unavailable by 79% of respondents. Conclusion: CMR is highly regarded for its clinical utility but underutilized due to operational barriers, mainly long waiting times and lack of specific competence. Perceived inadequacy in report quality is common and contributes to a consistent rate of second-opinion requests
CMR Mapping: The 4th-Era Revolution in Cardiac Imaging
Cardiac magnetic resonance (CMR) imaging has witnessed substantial progress with the advent of parametric mapping techniques, most notably T1 and T2 mapping. These advanced techniques provide valuable insights into a wide range of cardiac conditions, including ischemic heart disease, cardiomyopathies, inflammatory cardiomyopathies, heart valve disease, and athlete's heart. Mapping could be the first sign of myocardial injury and oftentimes precedes symptoms, changes in ejection fraction, and irreversible myocardial remodeling. The ability of parametric mapping to offer a quantitative assessment of myocardial tissue properties addresses the limitations of conventional CMR methods, which often rely on qualitative or semiquantitative data. However, challenges persist, especially in terms of standardization and reference value establishment, hindering the wider clinical adoption of parametric mapping. Future developments should prioritize the standardization of techniques to enhance their clinical applicability, ultimately optimizing patient care pathways and outcomes. In this review, we endeavor to provide insights into the potential contributions of CMR mapping techniques in enhancing the diagnostic processes across a range of cardiac conditions
Sex dimorphism in the myocardial response to aortic stenosis
Objectives: The goal of this study was to explore sex differences in myocardial remodeling in aortic stenosis (AS) by using echocardiography, cardiac magnetic resonance (CMR), and biomarkers.
Background: AS is a disease of both valve and left ventricle (LV). Sex differences in LV remodeling are reported in AS and may play a role in disease phenotyping.
Methods: This study was a prospective assessment of patients awaiting surgical valve replacement for severe AS using echocardiography, the 6-min walking test, biomarkers (high-sensitivity troponin T and N-terminal pro-brain natriuretic peptide), and CMR with late gadolinium enhancement and extracellular volume fraction, which dichotomizes the myocardium into matrix and cell volumes. LV remodeling was categorized into normal geometry, concentric remodeling, concentric hypertrophy, and eccentric hypertrophy
An accurate and time-efficient deep learning-based system for automated segmentation and reporting of cardiac magnetic resonance-detected ischemic scar
Background and objectives: Myocardial infarction scar (MIS) assessment by cardiac magnetic resonance provides prognostic information and guides patients' clinical management. However, MIS segmentation is time-consuming and not performed routinely. This study presents a deep-learning-based computational workflow for the segmentation of left ventricular (LV) MIS, for the first time performed on state-of-the-art dark-blood late gadolinium enhancement (DB-LGE) images, and the computation of MIS transmurality and extent.Methods: DB-LGE short-axis images of consecutive patients with myocardial infarction were acquired at 1.5T in two centres between Jan 1, 2019, and June 1, 2021. Two convolutional neural network (CNN) mod-els based on the U-Net architecture were trained to sequentially segment the LV and MIS, by processing an incoming series of DB-LGE images. A 5-fold cross-validation was performed to assess the performance of the models. Model outputs were compared respectively with manual (LV endo-and epicardial border) and semi-automated (MIS, 4-Standard Deviation technique) ground truth to assess the accuracy of the segmentation. An automated post-processing and reporting tool was developed, computing MIS extent (expressed as relative infarcted mass) and transmurality.Results: The dataset included 1355 DB-LGE short-axis images from 144 patients (MIS in 942 images). High performance (> 0.85) as measured by the Intersection over Union metric was obtained for both the LV and MIS segmentations on the training sets. The performance for both LV and MIS segmentations was 0.83 on the test sets.Compared to the 4-Standard Deviation segmentation technique, our system was five times quicker ( <1 min versus 7 +/- 3 min), and required minimal user interaction. Conclusions: Our solution successfully addresses different issues related to automatic MIS segmentation, including accuracy, time-effectiveness, and the automatic generation of a clinical report.(c) 2022 Elsevier B.V. All rights reserved
May Measurement Month 2019: an analysis of blood pressure screening results from Italy
: Cardiovascular (CV) diseases are burdened by high mortality and morbidity, being responsible for half of the deaths in Europe. Although hypertension is recognized as the most important CV risk factor, hypertension awareness, and blood pressure (BP) control are still unsatisfactory. In 2017 and 2018, respectively >10 000 and >5000 individuals took part in the May Measurement Month (MMM) campaign in Italy, of whom 30.6% and 26.3% were found to have high BP, respectively. To raise public awareness on the importance of hypertension and to collect BP data on a nation-wide scale in Italy. In the frame of the MMM campaign, an opportunistic cross-sectional survey of volunteers aged ≥18 years was carried out in May 2019. BP measurement, the definition of hypertension, and statistical analysis followed the standard MMM protocol. Screening was conducted in multiple sites by health personnel. Among the 10 182 people screened (females: 52.3%, mean age 58 ± 16years) mean BP was 127/78 mmHg, and 3171 (31.1%) participants had arterial hypertension, of whom 62.1% were aware of being hypertensive. Diabetes, body mass index >25 kg/m2 were associated with higher BP and previous myocardial infarction with lower BP. For the third consecutive year we collected a nation-wide snapshot of BP control in a large sample of individuals. The high participation, with some yearly fluctuations likely due to the limitations of the sampling technique, confirms the power of this kind of health campaign in reaching a significant number of people to raise awareness on health topics
An accurate and time-efficient deep learning-based system for automated segmentation and reporting of cardiac magnetic resonance-detected ischemic scar
BACKGROUND AND OBJECTIVES: Myocardial infarction scar (MIS) assessment by cardiac magnetic resonance provides prognostic information and guides patients' clinical management. However, MIS segmentation is time-consuming and not performed routinely. This study presents a deep-learning-based computational workflow for the segmentation of left ventricular (LV) MIS, for the first time performed on state-of-the-art dark-blood late gadolinium enhancement (DB-LGE) images, and the computation of MIS transmurality and extent. METHODS: DB-LGE short-axis images of consecutive patients with myocardial infarction were acquired at 1.5T in two centres between Jan 1, 2019, and June 1, 2021. Two convolutional neural network (CNN) models based on the U-Net architecture were trained to sequentially segment the LV and MIS, by processing an incoming series of DB-LGE images. A 5-fold cross-validation was performed to assess the performance of the models. Model outputs were compared respectively with manual (LV endo- and epicardial border) and semi-automated (MIS, 4-Standard Deviation technique) ground truth to assess the accuracy of the segmentation. An automated post-processing and reporting tool was developed, computing MIS extent (expressed as relative infarcted mass) and transmurality. RESULTS: The dataset included 1355 DB-LGE short-axis images from 144 patients (MIS in 942 images). High performance (> 0.85) as measured by the Intersection over Union metric was obtained for both the LV and MIS segmentations on the training sets. The performance for both LV and MIS segmentations was 0.83 on the test sets. Compared to the 4-Standard Deviation segmentation technique, our system was five times quicker (<1 min versus 7 ± 3 min), and required minimal user interaction. CONCLUSIONS: Our solution successfully addresses different issues related to automatic MIS segmentation, including accuracy, time-effectiveness, and the automatic generation of a clinical report
- …
