630 research outputs found

    Pancreatic pseudocystwith stent placement in the background of narcotic use: a case report

    Get PDF
    A 49 year old gentleman presents with recurrent abdominal pain. The patient has a known history of chronic pancreatitis, alcoholism and narcotic addiction. Work-up, including computed tomography (CT) of the abdomen, demonstrated a 5.6 × 5.8 cm fluid collection contiguous with the pancreas. This was not seen on CT 18 months earlier. The patient's pain did not improve with bowel rest and pain control. He was transferred to another institution for endoscopic placement of a transgastric pancreatic stent. The procedure decreased the size the cyst and the patient's pain became more manageable

    An EMG-based eating behaviour monitoring system with haptic feedback to promote mindful eating

    Get PDF
    Mindless eating, or the lack of awareness of the food we are consuming, has been linked to health problems attributed to unhealthy eating behaviour, including obesity. Traditional approaches used to moderate eating behaviour often rely on inaccurate self-logging, manual observations or bulky equipment. Overall, there is a need for an intelligent and lightweight system which can automatically monitor eating behaviour and provide feedback. In this paper, we investigate: i) the development of an automated system for detecting eating behaviour using wearable Electromyography (EMG) sensors, and ii) the application of such a system in combination with real time wristband haptic feedback to facilitate mindful eating. Data collected from 16 participants were used to develop an algorithm for detecting chewing and swallowing. We extracted 18 features from EMG and presented those features to different classifiers. We demonstrated that eating behaviour can be automatically assessed accurately using the EMG-extracted features and a Support Vector Machine (SVM): F1-Score=0.94 for chewing classification, and F1-Score=0.86 for swallowing classification. Based on this algorithm, we developed a system to enable participants to self-moderate their chewing behaviour using haptic feedback. An experiment study was carried out with 20 additional participants showing that participants exhibited a lower rate of chewing when haptic feedback delivered in forms of wristband vibration was used compared to a baseline and non-haptic condition (F (2,38)=58.243, p<0.001). These findings may have major implications for research in eating behaviour, providing key new insights into the impacts of automatic chewing detection and haptic feedback systems on moderating eating behaviour with the aim to improve health outcomes

    High-resolution digital phenotypes from consumer wearables and their applications in machine learning of cardiometabolic risk markers: cohort study

    Get PDF
    Background: Consumer-grade wearable devices enable detailed recordings of heart rate and step counts in free-living conditions. Recent studies have shown that summary statistics from these wearable recordings have potential uses for longitudinal monitoring of health and disease states. However, the relationship between higher resolution physiological dynamics from wearables and known markers of health and disease remains largely uncharacterized. Objective: We aimed to derive high-resolution digital phenotypes from observational wearable recordings and to examine their associations with modifiable and inherent markers of cardiometabolic disease risk. Methods: We introduced a principled framework to extract interpretable high-resolution phenotypes from wearable data recorded in free-living conditions. The proposed framework standardizes the handling of data irregularities; encodes contextual information regarding the underlying physiological state at any given time; and generates a set of 66 minimally redundant features across active, sedentary, and sleep states. We applied our approach to a multimodal data set, from the SingHEART study (NCT02791152), which comprises heart rate and step count time series from wearables, clinical screening profiles, and whole genome sequences from 692 healthy volunteers. We used machine learning to model nonlinear relationships between the high-resolution phenotypes on the one hand and clinical or genomic risk markers for blood pressure, lipid, weight and sugar abnormalities on the other. For each risk type, we performed model comparisons based on Brier scores to assess the predictive value of high-resolution features over and beyond typical baselines. We also qualitatively characterized the wearable phenotypes for participants who had actualized clinical events. Results: We found that the high-resolution features have higher predictive value than typical baselines for clinical markers of cardiometabolic disease risk: the best models based on high-resolution features had 17.9% and 7.36% improvement in Brier score over baselines based on age and gender and resting heart rate, respectively (P<.001 in each case). Furthermore, heart rate dynamics from different activity states contain distinct information (maximum absolute correlation coefficient of 0.15). Heart rate dynamics in sedentary states are most predictive of lipid abnormalities and obesity, whereas patterns in active states are most predictive of blood pressure abnormalities (P<.001). Moreover, in comparison with standard measures, higher resolution patterns in wearable heart rate recordings are better able to represent subtle physiological dynamics related to genomic risk for cardiometabolic disease (improvement of 11.9%-22.0% in Brier scores; P<.001). Finally, illustrative case studies reveal connections between these high-resolution phenotypes and actualized clinical events, even for borderline profiles lacking apparent cardiometabolic risk markers. Conclusions: High-resolution digital phenotypes recorded by consumer wearables in free-living states have the potential to enhance the prediction of cardiometabolic disease risk and could enable more proactive and personalized health management

    Impact of Splenectomy on Thrombocytopenia, Chemotherapy, and Survival in Patients with Unresectable Pancreatic Cancer

    Get PDF
    Patients with unresectable pancreatic cancer (PDAC) or endocrine tumors (PET) often develop splenic vein thrombosis, hypersplenism, and thrombocytopenia which limits the administration of chemotherapy. From 2001 to 2009, 15 patients with recurrent or unresectable PDAC or PET underwent splenectomy for hypersplenism and thrombocytopenia. The clinical variables of this group of patients were analyzed. The overall survival of patients with PDAC was compared to historical controls. Of the 15 total patients, 13 (87%) had PDAC and 2 (13%) had PET. All tumors were either locally advanced (n = 6, 40%) or metastatic (n = 9, 60%). The platelet counts significantly increased after splenectomy (p &lt; 0.01). All patients were able to resume chemotherapy within a median of 11.5 days (range 6–27). The patients with PDAC had a median survival of 20 months (range 4–67) from the time of diagnosis and 10.6 months (range 0.6–39.8) from the time of splenectomy. Splenectomy for patients with unresectable PDAC or PET who developed hypersplenism and thrombocytopenia that limited the administration of chemotherapy, significantly increased platelet counts, and led to resumption of treatment in all patients. Patients with PDAC had better disease-specific survival as compared to historical controls

    Resectable adenocarcinomas in the pancreatic head: the retroperitoneal resection margin is an independent prognostic factor

    Get PDF
    Pancreatic cancer is a lethal disease, and even after assumed margin-free pancreatoduodenectomy, most patients die within few years. The aims were to evaluate the importance of standardised histopathologic assessment for adequacy of reporting and survival estimates, and to report on prognostic factors in a setting of standardised histopathologic assessment. We performed immunohistochemical evaluation, slide review, and review of histopathologic reports from all pancreatoduodenectomies at Rikshospitalet University Hospital in 1980–2004. Reports from 1998-2004 at this institution were compared with reports from all other Norwegian institutions in the same period. Standardised histopathologic assessment and reporting was found necessary to avoid underestimation of poor prognostic factors, and to avoid misdiagnosis of tumours originating from non-pancreatic tissue (ampulla, distal bile duct, duodenum). Standardised histopathology was more important than surgical volume for completeness of reporting and for reliability of survival estimates, particularly with respect to lymph node evaluation. Immunostaining for MUC1 and MUC4 identified a subgroup of patients with particularly poor prognosis. Standardised histopathologic evaluation should be a first prerequisite to assure adequate histopathology after pancreatoduodenectomy. Immunostaining may identify tumour markers potentially targetable in future adjuvant treatments for pancreatic cancer

    Single Cell Deposition and Patterning with a Robotic System

    Get PDF
    Integrating single-cell manipulation techniques in traditional and emerging biological culture systems is challenging. Microfabricated devices for single cell studies in particular often require cells to be spatially positioned at specific culture sites on the device surface. This paper presents a robotic micromanipulation system for pick-and-place positioning of single cells. By integrating computer vision and motion control algorithms, the system visually tracks a cell in real time and controls multiple positioning devices simultaneously to accurately pick up a single cell, transfer it to a desired substrate, and deposit it at a specified location. A traditional glass micropipette is used, and whole- and partial-cell aspiration techniques are investigated to manipulate single cells. Partially aspirating cells resulted in an operation speed of 15 seconds per cell and a 95% success rate. In contrast, the whole-cell aspiration method required 30 seconds per cell and achieved a success rate of 80%. The broad applicability of this robotic manipulation technique is demonstrated using multiple cell types on traditional substrates and on open-top microfabricated devices, without requiring modifications to device designs. Furthermore, we used this serial deposition process in conjunction with an established parallel cell manipulation technique to improve the efficiency of single cell capture from ∼80% to 100%. Using a robotic micromanipulation system to position single cells on a substrate is demonstrated as an effective stand-alone or bolstering technology for single-cell studies, eliminating some of the drawbacks associated with standard single-cell handling and manipulation techniques
    corecore