17 research outputs found
Assessing the effect of closed-loop insulin delivery from onset of type 1 diabetes in youth on residual beta-cell function compared to standard insulin therapy (CLOuD study): a randomised parallel study protocol.
INTRODUCTION:Management of newly diagnosed type 1 diabetes (T1D) in children and adolescents is challenging for patients, families and healthcare professionals. The objective of this study is to determine whether continued intensive metabolic control using hybrid closed-loop (CL) insulin delivery following diagnosis of T1D can preserve C-peptide secretion, a marker of residual beta-cell function, compared with standard multiple daily injections (MDI) therapy. METHODS AND ANALYSIS:The study adopts an open-label, multicentre, randomised, parallel design, and aims to randomise 96 participants aged 10-16.9 years, recruited within 21 days of diagnosis with T1D. Following a baseline mixed meal tolerance test (MMTT), participants will be randomised to receive 24 months treatment with conventional MDI therapy or with CL insulin delivery. A further 24-month optional extension phase will be offered to all participants to continue with the allocated treatment. The primary outcome is the between group difference in area under the stimulated C-peptide curve (AUC) of the MMTT at 12 months post diagnosis. Analyses will be conducted on an intention-to-treat basis. Key secondary outcomes are between group differences in time spent in target glucose range (3.9-10 mmol/L), glycated haemoglobin (HbA1c) and time spent in hypoglycaemia (<3.9 mmol/L) at 12 months. Secondary efficacy outcomes include between group differences in stimulated C-peptide AUC at 24 months, time spent in target glucose range, glucose variability, hypoglycaemia and hyperglycaemia as recorded by periodically applied masked continuous glucose monitoring devices, total, basal and bolus insulin dose, and change in body weight. Cognitive, emotional and behavioural characteristics of participants and parents will be evaluated, and a cost-utility analysis performed to support adoption of CL as a standard treatment modality following diagnosis of T1D. ETHICS AND DISSEMINATION:Ethics approval has been obtained from Cambridge East Research Ethics Committee. The results will be disseminated by peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER:NCT02871089; Pre-results
Recommended from our members
Health professionals' views about who would benefit from using a closed-loop system: a qualitative study.
AIM: To explore health professionals' views about who would benefit from using a closed-loop system and who should be prioritized for access to the technology in routine clinical care. METHODS: Health professionals (n = 22) delivering the Closed Loop from Onset in type 1 Diabetes (CLOuD) trial were interviewed after they had ≥ 6 months' experience supporting participants using a closed-loop system. Data were analysed thematically. RESULTS: Interviewees described holding strong assumptions about the types of people who would use the technology effectively prior to the trial. Interviewees described changing their views as a result of observing individuals engaging with the closed-loop system in ways they had not anticipated. This included educated, technologically competent individuals who over-interacted with the system in ways which could compromise glycaemic control. Other individuals, who health professionals assumed would struggle to understand and use the technology, were reported to have benefitted from it because they stood back and allowed the system to operate without interference. Interviewees concluded that individual, family and psychological attributes cannot be used as pre-selection criteria and, ideally, all individuals should be given the chance to try the technology. However, it was recognized that clinical guidelines will be needed to inform difficult decisions about treatment allocation (and withdrawal), with young children and infants being considered priority groups. CONCLUSIONS: To ensure fair and equitable access to closed-loop systems, prejudicial assumptions held by health professionals may need to be addressed. To support their decision-making, clinical guidelines need to be made available in a timely manner
Recommended from our members
Closed-Loop Therapy and Preservation of C-Peptide Secretion in Type 1 Diabetes.
BACKGROUND: Whether improved glucose control with hybrid closed-loop therapy can preserve C-peptide secretion as compared with standard insulin therapy in persons with new-onset type 1 diabetes is unclear. METHODS: In a multicenter, open-label, parallel-group, randomized trial, we assigned youths 10.0 to 16.9 years of age within 21 days after a diagnosis of type 1 diabetes to receive hybrid closed-loop therapy or standard insulin therapy (control) for 24 months. The primary end point was the area under the curve (AUC) for the plasma C-peptide level (after a mixed-meal tolerance test) at 12 months after diagnosis. The analysis was performed on an intention-to-treat basis. RESULTS: A total of 97 participants (mean [±SD] age, 12±2 years) underwent randomization: 51 were assigned to receive closed-loop therapy and 46 to receive control therapy. The AUC for the C-peptide level at 12 months (primary end point) did not differ significantly between the two groups (geometric mean, 0.35 pmol per milliliter [interquartile range, 0.16 to 0.49] with closed-loop therapy and 0.46 pmol per milliliter [interquartile range, 0.22 to 0.69] with control therapy; mean adjusted difference, -0.06 pmol per milliliter [95% confidence interval {CI}, -0.14 to 0.03]). There was not a substantial between-group difference in the AUC for the C-peptide level at 24 months (geometric mean, 0.18 pmol per milliliter [interquartile range, 0.06 to 0.22] with closed-loop therapy and 0.24 pmol per milliliter [interquartile range, 0.05 to 0.30] with control therapy; mean adjusted difference, -0.04 pmol per milliliter [95% CI, -0.14 to 0.06]). The arithmetic mean glycated hemoglobin level was lower in the closed-loop group than in the control group by 4 mmol per mole (0.4 percentage points; 95% CI, 0 to 8 mmol per mole [0.0 to 0.7 percentage points]) at 12 months and by 11 mmol per mole (1.0 percentage points; 95% CI, 7 to 15 mmol per mole [0.5 to 1.5 percentage points]) at 24 months. Five cases of severe hypoglycemia occurred in the closed-loop group (in 3 participants), and one occurred in the control group; one case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In youths with new-onset type 1 diabetes, intensive glucose control for 24 months did not appear to prevent the decline in residual C-peptide secretion. (Funded by the National Institute for Health and Care Research and others; CLOuD ClinicalTrials.gov number, NCT02871089.)
Effect of the coronavirus disease 2019 pandemic on the quality of stroke care in stroke units and alternative wards: a national comparative analysis
Background and purpose Changes to hospital systems were implemented from March 2020 in Australia in response to the coronavirus disease 2019 pandemic, including decreased resources allocated to stroke units. We investigate changes in the quality of acute care for patients with stroke or transient ischemic attack during the pandemic according to patients' treatment setting (stroke unit or alternate ward). Methods We conducted a retrospective cohort study of patients admitted with stroke or transient ischemic attack between January 2019 and June 2020 in the Australian Stroke Clinical Registry (AuSCR). The AuSCR monitors patients' treatment setting, provision of allied health and nursing interventions, prescription of secondary prevention medications, and discharge destination. Weekly trends in the quality of care before and during the pandemic period were assessed using interrupted time series analyses. Results In total, 18,662 patients in 2019 and 8,850 patients in 2020 were included. Overall, 75% were treated in stroke units. Before the pandemic, treatment in a stroke unit was superior to alternate wards for the provision of all evidence-based therapies assessed. During the pandemic period, the proportion of patients receiving a swallow screen or assessment, being discharged to rehabilitation, and being prescribed secondary prevention medications decreased by 0.58% to 1.08% per week in patients treated in other ward settings relative to patients treated in stroke units. This change represented a 9% to 17% increase in the care gap between these treatment settings during the period of the pandemic that was evaluated (16 weeks). Conclusions During the first 6 months of the pandemic, widening care disparities between stroke units and alternate wards have occurred.Dominique A. Cadilhaca, Joosup Kima, Geoffrey Cloudc, Craig S. Andersone, Emma K. Tod ... et al