84 research outputs found

    Prevalence of potential underlying aetiology of macrocytic anaemia in Dutch general practice

    Get PDF
    Background: Macrocytic anaemia (MCV \xe2\x89\xa5 100 fL) is a relatively common finding in general practice. However, literature on the prevalence of the different causes in this population is limited. The prevalence of macrocytic anaemia and its underlying aetiology were analysed in a general practice population. The potential effect of the different aetiology on survival was also evaluated. Methods: Between the 1st of February 2007 and the 1st of February 2015, patients aged 50 years or older and presenting to their general practitioner with a newly diagnosed anaemia, were included in the study. Anaemia was defined as haemoglobin level below 13.7 g/dL in men and below 12.1 g/dL in women. A broad range of laboratory tests was performed for each patient. The causes of anaemia were consequently determined by two independent observers based on the laboratory results. Results: Of the 3324 included patients, 249 (7.5 %) displayed a macrocytic anaemia and were subsequently analysed. An underlying explanation could be established in 204 patients (81.9 %) with 27 patients (13.2 %) displaying multiple causes. Classic aetiology (i.e. alcohol abuse, vitamin B12/folic acid deficiency, haemolysis and possible bone marrow disease) was found in 115 patients. Alternative causes (i.e. anaemia of chronic disease, iron deficiency, renal anaemia and other causes) were encountered in 101 patients. In addition, a notable finding was the median gamma GT of 277 U/L in patients diagnosed with alcohol abuse (N = 24, IQR 118.0-925.5) and 23 U/L in the remaining cohort (N = 138, IQR 14.0-61.0). The distribution of gamma GT values was statistically different (P < 0.001). Five year survival rates were determined for six categories of causes, ranging from 39.9 % (95 % CI 12.9-66.9) for renal anaemia to 76.2 % (95 % CI 49.4-103.0) for the category multiple causes. Conclusion: In addition to classic explanations for macrocytosis, alternative causes are frequently encountered in patients with macrocytic anaemia in general practice

    First results on the search for chameleons with the KWISP detector at CAST

    Get PDF
    We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of 80pN at 95% confidence level. The detector is sensitive for direct coupling to matter 104 = ßm = 108, where the coupling to photons is locally bound to ß¿ = 1011

    First results of the CAST-RADES haloscope search for axions at 34.67 µeV

    Get PDF
    We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 µeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of ga¿ ¿ 4 × 10-13 GeV-1 over a mass range of 34.6738 µeV &lt; ma&lt; 34.6771 µeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 µeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities. © 2021, The Author(s)

    Improved search for solar chameleons with a GridPix detector at CAST

    Get PDF
    We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No significant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, beta(gamma) less than or similar to 5.7 x 10(10) for 1 < beta(m) < 10(6) at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to 12.5 T

    Registro Español de Trasplante Cardiaco. XXXI Informe Oficial de la Asociación de Insuficiencia Cardiaca de la Sociedad Española de Cardiología

    Get PDF
    Introducción y objetivos Se presentan las características clínicas y los resultados de los trasplantes cardiacos realizados en España con la actualización correspondiente a 2019. Métodos Se describen las características clínicas y los resultados de los trasplantes cardiacos realizados en 2019, así como las tendencias de estos en el periodo 2010-2018. Resultados En 2019 se realizaron 300 trasplantes (8.794 desde 1984; 2.745 entre 2010 y 2019). Respecto a años previos, los cambios más llamativos son el descenso hasta el 38% de los trasplantes realizados en código urgente, y la consolidación en el cambio de asistencia circulatoria pretrasplante, con la práctica desaparición del balón de contrapulsación (0, 7%), la estabilización del uso del oxigenador extracorpóreo de membrana (9, 6%) y el aumento de los dispositivos de asistencia ventricular (29%). La supervivencia en el trienio 2016-2018 es similar a la del trienio 2013-2015 (p = 0, 34), y ambas mejores que la del trienio 2010-2012 (p = 0, 002 y p = 0, 01 respectivamente). Conclusiones Se mantienen estables tanto la actividad del trasplante cardiaco en España como los resultados en supervivencia en los últimos 2 trienios. Hay una tendencia a realizar menos trasplantes urgentes, la mayoría con dispositivos de asistencia ventricular. Introduction and objectives: The present report describes the clinical characteristics and outcomes of heart transplants in Spain and updates the data to 2019. Methods: We describe the clinical characteristics and outcomes of heart transplants performed in Spain in 2019, as well as trends in this procedure from 2010 to 2018. Results: In 2019, 300 transplants were performed (8794 since 1984; 2745 between 2010 and 2019). Compared with previous years, the most notable findings were the decreasing rate of urgent transplants (38%), and the consolidation of the type of circulatory support prior to transplant, with an almost complete disappearance of counterpulsation balloon (0.7%), stabilization in the use of extracorporeal membrane oxygenation (9.6%), and an increase in the use of ventricular assist devices (29.0%). Survival from 2016 to 2018 was similar to that from 2013 to 2015 (P = .34). Survival in both these periods was better than that from 2010 to 2012 (P = .002 and P = .01, respectively). Conclusions: Heart transplant activity has remained stable during the last few years, as have outcomes (in terms of survival). There has been a trend to a lower rate of urgent transplants and to a higher use of ventricular assist devices prior to transplant

    Psicopatologia descritiva: aspectos históricos e conceituais

    Full text link
    corecore