93 research outputs found

    Radiometric Active Indoor Imaging in the W-Band

    Get PDF
    Millimeter wave passive imaging systems constitute a good compromise between resolution and penetration depth for a variety of imaging applications. In an outdoor scenario, the cold sky radiation, interacting with the reflectivity characteristics of the targets, constitutes the main source of contrast in the acquired images. In indoor applications such a source is not available, and higher thermal sensitivity is required. Alternatively, one has to provide an artificial illumination to the scene in order to increase its dynamic range. The implementation of an active source for a passive radiometer can, under certain conditions, increase the contrast of the images acquired and add extra information to the measurement. With such a setup, outdoor systems can be used for indoor observations (the absence of cold sky radiation is compensated with active illumination). The subject of our study is to better understand which kind of source and which setup can provide a diffuse illumination over the targets. This topic was investigated by conducting observations of various indoor scenes with two radiometers in the W-Band, using noise and continuous wave (CW) sources as illumination. In this paper we present the results achieved and our conclusions in order to provide an efficient illumination for indoor environment

    The STARTWAVE atmospheric water database

    Get PDF
    International audienceThe STARTWAVE (STudies in Atmospheric Radiative Transfer and Water Vapour Effects) project aims to investigate the role which water vapour plays in the climate system, and in particular its interaction with radiation. Within this framework, an ongoing water vapour database project was set up which comprises integrated water vapour (IWV) measurements made over the last ten years by ground-based microwave radiometers, Global Positioning System (GPS) receivers and sun photometers located throughout Switzerland at altitudes between 330 and 3584 m. At Bern (46.95° N, 7.44° E) tropospheric and stratospheric water vapour profiles are obtained on a regular basis and integrated liquid water, which is important for cloud characterisation, is also measured. Additional stratospheric water vapour profiles are obtained by an airborne microwave radiometer which observes large parts of the northern hemisphere during yearly flight campaigns. The database allows us to validate the various water vapour measurement techniques. Comparisons between IWV measured by the Payerne radiosonde with that measured at Bern by two microwave radiometers, GPS and sun photometer showed instrument biases within ±0.5 mm. The bias in GPS relative to sun photometer over the 2001 to 2004 period was ?0.8 mm at Payerne (46.81° N, 6.94° E, 490 m), which lies in the Swiss plains north of the Alps, and +0.6 mm at Davos (46.81° N, 9.84° E, 1598 m), which is located within the Alps in the eastern part of Switzerland. At Locarno (46.18° N, 8.78° E, 366 m), which is located on the south side of the Alps, the bias is +1.9 mm. The sun photometer at Locarno was found to have a bias of ?2.2 mm (13% of the mean annual IWV) relative to the data from the closest radiosonde station at Milano. This result led to a yearly rotation of the sun photometer instruments between low and high altitude stations to improve the calibrations. In order to demonstrate the capabilites of the database for studying water vapour variations, we investigated a front which crossed Switzerland between 18 November 2004 and 19 November 2004. During the frontal passage, the GPS and microwave radiometers at Bern and Payerne showed an increase in IWV of between 7 and 9 mm. The GPS IWV measurements were corrected to a standard height of 500 m, using an empirically derived exponential relationship between IWV and altitude. A qualitative comparison was made between plots of the IWV distribution measured by the GPS and the 6.2 µm water vapour channel on the Meteosat Second Generation (MSG) satellite. Both showed that the moist air moved in from a northerly direction, although the MSG showed an increase in water vapour several hours before increases in IWV were detected by GPS or microwave radiometer. This is probably due to the fact that the satellite instrument is sensitive to an atmospheric layer at around 320 hPa, which makes a contribution of one percent or less to the IWV

    A millimeter wave technique for measuring ice thickness on the Space Shuttle's external tank

    Full text link
    The external fueltank of the Space Shuttle contains extremely lowtemperature propellents. A layer of material known as SOFI (Spray-On Foam Insulation) covering the outside of the fueltank provides thermal insulation between the aluminum surface of the fueltank and the ambient air. In spite of this insulation, under certain conditions ice formation will occur on the surface of the SOFI. Ice on the external fueltank can be detrimental to the launch and it is important to detect its presence and measure its thickness. This paper describes the design of a millimeter-wave radiometer technique developed for this purpose. The design is based on model calculations and measurements of the emission properties of a panel from the external fueltank performed at 35, 94 and 140 GHz. Two sets of measurements were performed, one for the unmodified rough-surface SOFI panel and another for a panel whose surface was sanded down to produce a smooth surface interface with the ice cover. The latter was used to evaluate the results of radiative transfer calculations which are much easier to perform for multilayer structures with plane boundaries. We present experimental evidence demonstrating that the technique developed can accurately predict ice thickness in the case of the smooth-surface SOFI panel. For the original (rough-surface) panel, the emission levels observed were considerably higher than predicted by the model. Both cases however exhibited comparable sensitivities to ice thickness (∼ K/mm at 35 GHz, 4 K/mm at 94 GHz, and 5 K/mm at 140 GHz).Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/44545/1/10762_2005_Article_BF01883870.pd

    Short-term physical exercise impacts on the human holobiont obtained by a randomised intervention study

    Get PDF
    Background Human well-being has been linked to the composition and functional capacity of the intestinal microbiota. As regular exercise is known to improve human health, it is not surprising that exercise was previously described to positively modulate the gut microbiota, too. However, most previous studies mainly focused on either elite athletes or animal models. Thus, we conducted a randomised intervention study that focused on the effects of different types of training (endurance and strength) in previously physically inactive, healthy adults in comparison to controls that did not perform regular exercise. Overall study duration was ten weeks including six weeks of intervention period. In addition to 16S rRNA gene amplicon sequencing of longitudinally sampled faecal material of participants (six time points), detailed body composition measurements and analysis of blood samples (at baseline and after the intervention) were performed to obtain overall physiological changes within the intervention period. Activity tracker devices (wrist-band wearables) provided activity status and sleeping patterns of participants as well as exercise intensity and heart measurements. Conclusions We could show that different types of exercise have distinct but moderate effects on the overall physiology of humans and very distinct microbial changes in the gut. The observed overall changes during the intervention highlight the importance of physical activity on well-being. Future studies should investigate the effect of exercise on a longer timescale, investigate different training intensities and consider high-resolution shotgun metagenomics technology. Trial registration DRKS, DRKS00015873 . Registered 12 December 2018; Retrospectively registered

    Promising Metabolite Profiles in the Plasma and CSF of Early Clinical Parkinson's Disease

    Get PDF
    Parkinson's disease (PD) shows high heterogeneity with regard to the underlying molecular pathogenesis involving multiple pathways and mechanisms. Diagnosis is still challenging and rests entirely on clinical features. Thus, there is an urgent need for robust diagnostic biofluid markers. Untargeted metabolomics allows establishing low-molecular compound biomarkers in a wide range of complex diseases by the measurement of various molecular classes in biofluids such as blood plasma, serum, and cerebrospinal fluid (CSF). Here, we applied untargeted high-resolution mass spectrometry to determine plasma and CSF metabolite profiles. We semiquantitatively determined small-molecule levels (≤1.5 kDa) in the plasma and CSF from early PD patients (disease duration 0-4 years; n = 80 and 40, respectively), and sex- and age-matched controls (n = 76 and 38, respectively). We performed statistical analyses utilizing partial least square and random forest analysis with a 70/30 training and testing split approach, leading to the identification of 20 promising plasma and 14 CSF metabolites. These metabolites differentiated the test set with an AUC of 0.8 (plasma) and 0.9 (CSF). Characteristics of the metabolites indicate perturbations in the glycerophospholipid, sphingolipid, and amino acid metabolism in PD, which underscores the high power of metabolomic approaches. Further studies will enable to develop a potential metabolite-based biomarker panel specific for PD
    corecore