18,732 research outputs found
Metabolic risk score indexes validation in overweight healthy people
The constellation of adverse cardiovascular disease (CVD) and metabolic risk factors, including elevated abdominal obesity, blood pressure (BP), glucose, and triglycerides (TG) and lowered high-density lipoprotein-cholesterol (HDL-C), has been termed the metabolic syndrome (MetSyn) [1]. A number of different definitions have been developed by the World Health Organization (WHO) [2], the National Cholesterol Education Program Adult Treatment Panel III (ATP III) [3], the European Group for the Study of Insulin Resistance (EGIR) [4] and, most recently, the International Diabetes Federation (IDF) [5]. Since there is no universal definition of the Metabolic Syndrome, several authors have derived different risk scores to represent the clustering of its components [6-11]
PANIC: the new panoramic NIR camera for Calar Alto
PANIC is a wide-field NIR camera, which is currently under development for
the Calar Alto observatory (CAHA) in Spain. It uses a mosaic of four Hawaii-2RG
detectors and covers the spectral range from 0.8-2.5 micron(z to K-band). The
field-of-view is 30x30 arcmin. This instrument can be used at the 2.2m
telescope (0.45arcsec/pixel, 0.5x0.5 degree FOV) and at the 3.5m telescope
(0.23arcsec/pixel, 0.25x0.25 degree FOV). The operating temperature is about
77K, achieved by liquid Nitrogen cooling. The cryogenic optics has three flat
folding mirrors with diameters up to 282 mm and nine lenses with diameters
between 130 mm and 255 mm. A compact filter unit can carry up to 19 filters
distributed over four filter wheels. Narrow band (1%) filters can be used. The
instrument has a diameter of 1.1 m and it is about 1 m long. The weight limit
of 400 kg at the 2.2m telescope requires a light-weight cryostat design. The
aluminium vacuum vessel and radiation shield have wall thicknesses of only 6 mm
and 3 mm respectively.Comment: This paper has been presented in the SPIE of Astronomical Telescopes
and Instrumentation 2008 in Marseille (France
Characterization of a Subsurface Biosphere in a Massive Sulfide Deposit At Rio Tinto, Spain: Implications For Extant Life On Mars
The recent discovery of abundant sulfate minerals, particularly Jarosite by the Opportunity Rover at Sinus Merdiani on Mars has been interpreted as evidence for an acidic lake or sea on ancient Mars [1,2], since the mineral Jarosite is soluble in liquid water at pH above 4. The most likely mechanism to produce sufficient protons to acidify a large body of liquid water is near surface oxidation of pyrite rich deposits [3]. The acidic waters of the Rio Tinto, and the associated deposits of Hematite, Goethite, and Jarosite have been recognized as an important chemical analog to the Sinus Merdiani site on Mars [4]. The Rio Tinto is a river in southern Spain that flows 100 km from its source in the Iberian pyrite belt, one of the Earth's largest Volcanically Hosted Massive Sulfide (VHMS) provinces, into the Atlantic ocean. The river originates in artesian springs emanating from ground water that is acidified by the interaction with subsurface pyrite ore deposits. The Mars Analog Rio Tinto Experiment (MARTE) has been investigating the hypothesis that a subsurface biosphere exists at Rio Tinto living within the VHMS deposit living on chemical energy derived from sulfur and iron minerals. Reduced iron and sulfur might provide electron donors for microbial metabolism while in situ oxidized iron or oxidants entrained in recharge water might provide electron acceptors
Reliability and reproductibility of skin temperature of overweight subjects by an infrared thermograpy software designed for human beings
The technical improvement and new applications of Infrared Thermography (IRT) with healthy subjects should be accompanied by results about the reproducibility of IRT measurements in different popula-tion groups. In addition, there is a remarkable necessity of a larger supply on software to analyze IRT images of human beings. Therefore, the objectives of this study were: firstly, to investigate the reproducibility of skin temperature (Tsk) on overweight and obese subjects using IRT in different Regions of Interest (ROI), moments and side-to-side differences (?T); and secondly, to check the reliability of a new software called Termotracker®, specialized on the analysis of IRT images of human beings. Methods: 22 overweight and obese males (11) and females (11) (age: 41,51±7,76 years; height: 1,65±0,09 m; weight: 82,41±11,81 Kg; BMI: 30,17±2,58 kg/m²) were assessed in two consecutive thermograms (5 seconds in-between) by the same observer, using an infrared camera (FLIR T335, Sweden) to get 4 IRT images from the whole body. 11 ROI were selected using Termotracker® to analyze its reproducibility and reliability through Intra-class Correlation Coefficient (ICC) and Coefficient of Variation (CV) values. Results: The reproducibility of the side-to-side differences (?T) between two consecutive thermograms was very high in all ROIs (Mean ICC = 0,989), and excellent between two computers (Mean ICC = 0,998). The re-liability of the software was very high in all the ROIs (Mean ICC = 0,999). Intraexaminer reliability analysing the same subjects in two consecutive thermograms was also very high (Mean ICC = 0,997). CV values of the different ROIs were around 2%. Conclusions: Skin temperature on overweight subjects had an excellent reproducibility for consecutive ther-mograms. The reproducibility of thermal asymmetries (?T) was also good but it had the influence of several factors that should be further investigated. Termotracker® reached excellent reliability results and it is a relia-ble and objective software to analyse IRT images of humans beings
Iodine chemistry in the troposphere and its effect on ozone
Despite the potential influence of iodine chemistry on the oxidizing capacity of the troposphere, reactive iodine distributions and their impact on tropospheric ozone remain almost unexplored aspects of the global atmosphere. Here we present a comprehensive global modelling experiment aimed at estimating lower and upper limits of the inorganic iodine burden and its impact on tropospheric ozone. Two sets of simulations without and with the photolysis of IxOy oxides (i.e. I2O2, I2O3 and I2O4) were conducted to define the range of inorganic iodine loading, partitioning and impact in the troposphere. Our results show that the most abundant daytime iodine species throughout the middle to upper troposphere is atomic iodine, with an annual average tropical abundance of (0.15-0.55) pptv. We propose the existence of a "tropical ring of atomic iodine" that peaks in the tropical upper troposphere (∼11-14 km) at the equator and extends to the sub-tropics (30°N-30°S). Annual average daytime I = IO ratios larger than 3 are modelled within the tropics, reaching ratios up to ∼20 during vigorous uplift events within strong convective regions. We calculate that the integrated contribution of catalytic iodine reactions to the total rate of tropospheric ozone loss (IOx Loss) is 2-5 times larger than the combined bromine and chlorine cycles. When IxOy photolysis is included, IOx Loss represents an upper limit of approximately 27, 14 and 27% of the tropical annual ozone loss for the marine boundary layer (MBL), free troposphere (FT) and upper troposphere (UT), respectively, while the lower limit throughout the tropical troposphere is ∼9 %. Our results indicate that iodine is the second strongest ozone-depleting family throughout the global marine UT and in the tropical MBL. We suggest that (i) iodine sources and its chemistry need to be included in global tropospheric chemistry models, (ii) experimental programs designed to quantify the iodine budget in the troposphere should include a strategy for the measurement of atomic I, and (iii) laboratory programs are needed to characterize the photochemistry of higher iodine oxides to determine their atmospheric fate since they can potentially dominate halogen-catalysed ozone destruction in the troposphere
Association of VAV2 and VAV3 polymorphisms with cardiovascular risk factors
Hypertension, diabetes and obesity are cardiovascular risk factors closely associated to the development of renal and cardiovascular target organ damage. VAV2 and VAV3, members of the VAV family proto-oncogenes, are guanosine nucleotide exchange factors for the Rho and Rac GTPase family, which is related with cardiovascular homeostasis. We have analyzed the relationship between the presence of VAV2 rs602990 and VAV3 rs7528153 polymorphisms with cardiovascular risk factors and target organ damage (heart, vessels and kidney) in 411 subjects. Our results show that being carrier of the T allele in VAV2 rs602990 polymorphism is associated with an increased risk of obesity, reduced levels of ankle-brachial index and diastolic blood pressure and reduced retinal artery caliber. In addition, being carrier of T allele is associated with increased risk of target organ damage in males. On the other hand, being carrier of the T allele in VAV3 rs7528153 polymorphism is associated with a decreased susceptibility of developing a pathologic state composed by the presence of hypertension, diabetes, obesity or cardiovascular damage, and with an increased risk of developing altered basal glycaemia. This is the first report showing an association between VAV2 and VAV3 polymorphisms with cardiovascular risk factors and target organ damage
EUROnu-WP6 2010 Report
This is a summary of the work done by the Working Package 6 (Physics) of the
EU project "EUROnu" during the second year of activity of the project.Comment: 82 pages, 51 eps figure
- …
