573 research outputs found

    Performance Benefits of Pre- and Per-cooling on Self-paced Versus Constant Workload Exercise:A Systematic Review and Meta-analysis

    Get PDF
    BACKGROUND AND OBJECTIVE: Exercise in hot environments impairs endurance performance. Cooling interventions can attenuate the impact of heat stress on performance, but the influence of an exercise protocol on the magnitude of performance benefit remains unknown. This meta-analytical review compared the effects of pre- and per-cooling interventions on performance during self-paced and constant workload exercise in the heat.METHODS: The study protocol was preregistered at the Open Science Framework ( https://osf.io/wqjb3 ). A systematic literature search was performed in PubMed, Web of Science, and MEDLINE from inception to 9 June, 2023. We included studies that examined the effects of pre- or per-cooling on exercise performance in male individuals under heat stress (&gt; 30 °C) during self-paced or constant workload exercise in cross-over design studies. Risk of bias was assessed using the Cochrane Risk of Bias Tool for randomized trials.RESULTS: Fifty-nine studies (n = 563 athletes) were identified from 3300 records, of which 40 (n = 370 athletes) used a self-paced protocol and 19 (n = 193 athletes) used a constant workload protocol. Eighteen studies compared multiple cooling interventions and were included more than once (total n = 86 experiments and n = 832 paired measurements). Sixty-seven experiments used a pre-cooling intervention and 19 used a per-cooling intervention. Average ambient conditions were 34.0 °C [32.3-35.0 °C] and 50.0% [40.0-55.3%] relative humidity. Cooling interventions attenuated the performance decline in hot conditions and were more effective during a constant workload (effect size [ES] = 0.62, 95% confidence interval [CI] 0.44-0.81) compared with self-paced exercise (ES = 0.30, 95% CI 0.18-0.42, p = 0.004). A difference in performance outcomes between protocols was only observed with pre-cooling (ES = 0.74, 95% CI 0.50-0.98 vs ES = 0.29, 95% CI 0.17-0.42, p = 0.001), but not per-cooling (ES = 0.45, 95% CI 0.16-0.74 vs ES = 0.35, 95% CI 0.01-0.70, p = 0.68).CONCLUSIONS: Cooling interventions attenuated the decline in performance during exercise in the heat, but the magnitude of the effect is dependent on exercise protocol (self-paced vs constant workload) and cooling type (pre- vs per-cooling). Pre-cooling appears to be more effective in attenuating the decline in exercise performance during a constant workload compared with self-paced exercise protocols, whereas no differences were found in the effectiveness of per-cooling.</p

    Управление финансовой устойчивостью и рентабельностью предприятия

    Get PDF
    Целью статьи является изучение значения управления финансовой устойчивостью и рентабельностью предприятия в современных условиях хозяйствования

    Plasma for Electrification of Chemical Industry: a Case Study on CO2 Reduction

    Get PDF
    Significantly increasing the share of (intermittent) renewable power in the chemical industry is imperative to meet increasingly stricter limits on CO2 exhaust that are being implemented within Europe. This paper aims to evaluate the potential of a plasma process that converts input CO2 into a pure stream of CO to aid in renewable energy penetration in this sector. A realistic process design is constructed to serve as a basis for an economical analysis. The manufacturing cost price of CO is estimated at 1.2 kUS$/ton CO. A sensitivity analysis shows that separation is the dominant cost factor, so that improving conversion is currently more effective to lower the price than e.g. energy efficiency.</p

    The importance of thermal dissociation in CO2 microwave discharges investigated by power pulsing and rotational Raman scattering

    Get PDF
    The input power of a CO2 microwave plasma is modulated at kHz rate in scans of duty cycle at constant average power to investigate gas heating dynamics and its relation to dissociation efficiency. Rotational temperature profiles obtained from rotational Raman scattering reveal peak temperatures of up to 3000 K, while the edge temperature remains cold (500 K). During the plasma \u27OFF\u27-period, the gas cools down convectively, but remains overall too hot to allow for strong overpopulation of vibrational modes (2200 K in the core). Fast optical imaging monitors plasma volume variations and shows that power density scales with peak power. As dissociation scales with observed peak rotational temperature, it is concluded that thermal processes dominate. A simple 0D model is constructed which explains how higher power density favors dissociation over radial energy transport. Thermal decomposition is reviewed in relation to quenching oxygen radicals with vibrationally excited CO2, to reflect on earlier reported record efficiencies of 90%.</p

    Joint angle variability and co-variation in a reaching with a rod task

    Get PDF
    The problem at the heart of motor control is how the myriad units of the neuromotor system are coordinated to perform goal-directed movements. Although for long these numerous degrees of freedom (DOFs) were considered redundant, recent views emphasize more that the DOFs should be considered abundant, allowing flexible performance. We studied how variability in arm joints was employed to stabilize the displaced end-effector in tool use to examine how the neuromotor system flexibly exploits DOFs in the upper extremity. Participants made pointing movements with the index finger and with the index finger extended by rods of 10, 20, and 30 cm. Using the uncontrolled manifold (UCM) method, the total joint angle variance was decomposed into two parts, the joint angle variance that did not affect the position of the end-effector (VUCM) and the variance that results in a deviation of the position of the end-effector from its mean (VORT). Analyses showed that some angles depended on length of the rod in use. For all rod lengths, VUCM was larger than VORT, and this did not differ over rod lengths, demonstrating that the arm was organized into a synergy. Finally, the variation in the joint angles in the arm as well as the degree of co-variation between these angles did not differ for the rod’s tip and the hand. We concluded that synergies are formed in the arm during reaching with an extended end-effector and those synergies stabilize different parts of the arm+rod system equally

    Comparison of two telemetric intestinal temperature devices with rectal temperature during exercise.

    Get PDF
    The experienced discomfort of rectal probes and esophageal probes for the estimation of body core temperatures has triggered the development of GI-capsules that are easy acceptable for athletes and workers due to their non-invasive characteristics.&#13; We compare two new GI-capsule devices with rectal temperature during cycle ergometer exercise and rest. Eight participants followed a protocol of (i) 30 min exercise with a power output of 130 W, (ii) 5 min rest, (iii) 10 min self-paced maximum exercise, and (iv) 15 min rest. Core temperature was measured using two GI-capsule devices (e-Celsius and myTemp) and rectal temperature.&#13; The myTemp system gave temperatures indifferent different from rectal temperature during rest and exercise. However, the factory calibrated e-Celsius system, showed a systematic underestimation of rectal temperature of 0.2 °C that is corrected in the 2018 versions. Finally, both GI-capsules react faster to temperature changes in the body compared to the rectal temperature probe during the rest period following maximum exercise

    Commissioning of inline ECE system within waveguide based ECRH transmission systems on ASDEX upgrade

    Get PDF
    A CW capable inline electron cyclotron emission (ECE) separation system for feedback control, featuring oversized corrugated waveguides, is commissioned on ASDEX upgrade (AUG). The system is based on a combination of a polarization independent, non-resonant, Mach-Zehnder diplexer equipped with dielectric plate beam splitters [2, 3] employed as corrugated oversized waveguide filter, and a resonant Fast Directional Switch, FADIS [4, 5, 6, 7] as ECE/ECCD separation system. This paper presents an overview of the system, the low power characterisation tests and first high power commissioning on AUG

    The role of a probiotics mixture in the treatment of childhood constipation: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Inconsistent data exist about the efficacy of probiotics in the treatment of constipation. Several studies in adults with constipation showed positive effects of probiotics on constipation. Inconsistent data exist regarding the effect of a single probiotic strain in constipated children. The aim of this pilot study was to determine the effect of a mixture of probiotics containing bifidobacteria and lactobacilli in the treatment of childhood constipation.</p> <p>Methods</p> <p>Children aged 4–16 years with constipation as defined by the Rome III criteria were eligible for the study. During a 4 week period, children received a daily mix of 4 × 10<sup>9 </sup>colony forming units of a probiotic mixture (<it>Ecologic</it><sup>®</sup><it>Relief</it>) containing Bifidobacteria (B.) bifidum, B. infantis, B. longum, Lactobacilli (L.) casei, L. plantarum and L. rhamnosus. Primary outcome measures were frequency of bowel movements (BMs) per week and stool consistency. Secondary outcome measures were number of faecal incontinence episodes per week, abdominal pain and side effects.</p> <p>Results</p> <p>Twenty children, 50% male, median age 8 (range 4–16) were included.</p> <p>The frequency of BMs per week increased from 2.0 (1.0–5.0) to 4.2 (0.0–16.0) in week 2 (p = 0.10) and 3.8 (2.1–7.0) in week 4 (p = 0.13). In 12 children presenting with <3 BMs/week, BMs per week increased significantly from 1.0 (0.0–2.0) to 3.0 (0.0–7.0) in week 2 (p = 0.01) and 3.0 (0.0–10.0) in week 4 (p = 0.01). The stool consistency was reported as hard in 7 children at baseline, in 4 children at week 2 (p = 0.23) and in 6 children after 4 weeks of treatment (p = 1.00). A significant decrease in number of faecal incontinence episodes per week was found in the entire group: 4.0 (0.0–35.0) to 1.5 (0.0–14.0) in week 2 (p = 0.01) and 0.3 (0.0–7.0) in week 4 (p = 0.001). The presence of abdominal pain decreased significantly from 45% to 25% in week 2 (p = 0.04) and 20% at week 4 (p = 0.006). No side effects were reported.</p> <p>Conclusion</p> <p>This pilot study shows that a mixture of probiotics, has positive effects on symptoms of constipation. To confirm these findings, a large randomised placebo controlled trial is required.</p
    corecore