1,086 research outputs found

    Finite element models for brush-debris interaction in road sweeping

    Get PDF
    In this paper, 2-D and 3-D finite element (FE) models for particle removal mechanisms are constructed to study the interaction between brush tines and debris in road sweeping processes. A 2-D contact FE analysis is first performed to analyse the contact behaviour between a flicking brush tine and an object to sweep. Using this model, the removal mechanisms are studied and analysed. Furthermore, the effect of brush penetration on debris removal is investigated. The 2-D sweeping model is extended to an accurate 3-D contact model, which overcomes some geometric errors in the 2-D model. From the results, it is suggested that the major removal mechanisms are a horizontal dragging force and a rolling moment generated by the external forces. It is also found that penetration has a positive contribution when it is relatively small in a non-sticky environment. Furthermore, in this environment, it is found that sweeping loads have a small effect on the removal process as either flicking tines or cutting tines can produce adequate removal loads

    Multi-vessel stenting during primary percutaneous coronary intervention for acute myocardial infarction. A single-center experience

    Get PDF
    BACKGROUND: Recanalization of the culprit lesion is the main goal of primary angioplasty for acute ST-segment elevation myocardial infarction (STEMI). Patients presenting with acute myocardial infarction and multivessel disease are, therefore, usually subjected to staged procedures, with the primary percutaneous coronary intervention (PCI) confined to recanalization of the infarct-related artery (IRA). Theoretically at least, early relief of stenoses of non-infarct-related arteries could promote collateral circulation, which could help to limit the infarct size. However, the safety and feasibility of such an approach has not been adequately established. METHODS: In this single-center prospective study we examined 73 consecutive patients who had an acute STEMI and at least one or more lesions > or = 70% in a major epicardial vessel other than the infarct-related artery. In the first 28 patients, forming the multi-vessel (MV) PCI group, all lesions were treated during the primary procedure. In the following 45 patients, forming the culprit-only (CO) PCI group, only the culprit lesion was treated during the initial procedure, followed by either planned-staged or ischemia-driven revascularization of the non-culprit lesions. Fluoroscopy time and contrast dye amount were compared between both groups, and patients were followed up for one year for major adverse cardiac events (MACE) and other significant clinical events. RESULTS: The two groups were well balanced in terms of clinical characteristics, number of diseased vessels and angiographic characteristics of the culprit lesion. In the MV-PCI group, 2.51 lesions per patient were treated using 2.96 +/- 1.34 stents (1.00 lesions and 1.76 +/- 1.17 stents in the CO-PCI group, both p < 0.001). The fluoroscopy time increased from 10.3 (7.2-16.9) min in the CO-PCI group to 12.5 (8.5-19.3) min in the MV-PCI group (p = 0.22), and the amount of contrast used from 200 (180-250) ml to 250 (200-300) ml, respectively (p = 0.16). Peak CK and CK-MB were significantly lower in patients of the MV-PCI group (843 +/- 845 and 135 +/- 125 vs 1652 +/- 1550 and 207 +/- 155 U/l, p < 0.001 and 0.01, respectively). Similar rates of major adverse cardiac events at one year were observed in the two groups (24% and 28% in multi-vessel and culprit treatment groups, p = 0.73). The incidence of new revascularization in both infarct- and non-infarct-related arteries was also similar (24% and 28%, respectively, p = 0.73). CONCLUSION: We may state from this limited experience that a multi-vessel stenting approach for patients with acute STEMI and multi-vessel disease is feasible and probably safe during routine clinical practice. Our data suggest that this approach may help to limit the infarct size. However, larger studies, perhaps using drug-eluting stents, are still needed to further evaluate the safety and efficiency of this procedure, and whether it is associated with a lower need of subsequent revascularization and lower costs

    Validation of the surface downwelling solar irradiance estimates of the HelioClim-3 database in Egypt

    Get PDF
    International audienceHelioClim-3 (HC3) is a database providing time series of the surface downwelling solar irradiance that are computed from images of the Meteosat satellites. This paper presents the validation results of the hourly global horizontal irradiance (GHI) and direct normal irradiance (DNI), i.e., beam irradiance at normal incidence, of versions four and five of HC3 at seven Egyptian sites. The validation is performed for all-sky conditions, as well as cloud-free conditions. Both versions of HC3 provide similar OPEN ACCESS Remote Sens. 2015, 7 9270 performances whatever the conditions. Another comparison is made with the estimates provided by the McClear database that is restricted to cloud-free conditions. All databases capture well the temporal variability of the GHI in all conditions, McClear being superior for cloud-free cases. In cloud-free conditions for the GHI, the relative root mean square error (RMSE) are fairly similar, ranging from 6% to 15%; both HC3 databases exhibit a smaller bias than McClear. McClear offers an overall better performance for the cloud-free DNI estimates. For all-sky conditions, the relative RMSE for GHI ranges from 10% to 22%, except one station, while, for the DNI, the results are not so good for the two stations with DNI measurements

    Further evidence for association of hepatitis C infection with parenteral schistosomiasis treatment in Egypt

    Get PDF
    BACKGROUND: Hepatitis C virus (HCV) infection and schistosomiasis are major public health problems in the Nile Delta of Egypt. To control schistosomiasis, mass treatment campaigns using tartar emetic injections were conducted in the 1960s through 1980s. Evidence suggests that inadequately sterilized needles used in these campaigns contributed to the transmission of HCV in the region. To corroborate this evidence, this study evaluates whether HCV infections clustered within houses in which household members had received parenteral treatment for schistosomiasis. METHODS: A serosurvey was conducted in a village in the Nile Delta and residents were questioned about prior treatment for schistosomiasis. Sera were evaluated for the presence of antibodies to HCV. The GEE2 approach was used to test for clustering of HCV infections, where correlation of HCV infections within household members who had been treated for schistosomiasis was the parameter of interest. RESULTS: A history of parenteral treatment for schistosomiasis was observed to cluster within households, OR for clustering: 2.44 (95% CI: 1.47–4.06). Overall, HCV seropositivity was 40% (321/796) and was observed to cluster within households that had members who had received parenteral treatment for schistosomiasis, OR for clustering: 1.76 (95% CI: 1.05–2.95). No such evidence for clustering was found in the remaining households. CONCLUSION: Clustering of HCV infections and receipt of parenteral treatment for schistosomiasis within the same households provides further evidence of an association between the schistosomiasis treatment campaigns and the high HCV seroprevalence rates currently observed in the Nile delta of Egypt

    Mutations in ASXL1 are associated with poor prognosis across the spectrum of malignant myeloid diseases

    Get PDF
    The ASXL1 gene is one of the most frequently mutated genes in malignant myeloid diseases. The ASXL1 protein belongs to protein complexes involved in the epigenetic regulation of gene expression. ASXL1 mutations are found in myeloproliferative neoplasms (MPN), myelodysplastic syndromes (MDS), chronic myelomonocytic leukemia (CMML) and acute myeloid leukemia (AML). They are generally associated with signs of aggressiveness and poor clinical outcome. Because of this, a systematic determination of ASXL1 mutational status in myeloid malignancies should help in prognosis assessment

    Rationale and design of a randomized clinical trial comparing safety and efficacy of myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: The LANDMARK trial

    Get PDF
    BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial
    corecore