226 research outputs found

    Experimental Investigation into the Influence of Backfill Types on the Vibro-acoustic Characteristics of Leaks in MDPE Pipe

    Get PDF
    Pipe leak location estimates are commonly conducted using Vibro-Acoustic Emission (VAE) based methods, usually using accelerometers or hydrophones. Successful estimation of a leak's location is dependent on a number of factors, including the speed of sound, resonance, backfill, reflections from other sources, leak shape and size. However, despite some investigation into some of the aforementioned factors, the influence of backfill type on a leak's VAE signal has still not been experimentally quantified. A limited number of studies have attempted to quantify the effects of backfill. However, all of these studies couple other variables which could be equally responsible for their observed changes in leak signal. There have been no controlled studies where one variable can be directly compared to one another (i.e. all variables remain constant, only changing backfill type). The aim of this paper is to better characterise the influence of backfill on a leak's VAE signal by individually isolating all variables. For the first time, this paper demonstrates the influence of backfill on leak VAE signal by keeping all other variables consistent. It was found that the backfill type had a strong influence on the frequency and amplitude of leak signals, which is likely to have a significant impact on the accuracy of leak location estimates

    First report of paired ventral endites in a hurdiid radiodont

    Get PDF
    Radiodonta, large Palaeozoic nektonic predators, occupy a pivotal evolutionary position as stem-euarthropods and filled important ecological niches in early animal ecosystems. Analyses of the anatomy and phylogenetic affinity of these large nektonic animals have revealed the origins of the euarthropod compound eye and biramous limb, and interpretations of their diverse feeding styles have placed various radiodont taxa as primary consumers and apex predators. Critical to our understanding of both radiodont evolution and ecology are the paired frontal appendages; however, the vast differences in frontal appendage morphology between and within different radiodont families have made it difficult to identify the relative timings of character acquisitions for this body part

    The validity of a head-worn inertial sensor for measurements of swimming performance

    Get PDF
    The validity of the TritonWear ® device to measure swimming performance Was Investigated, with a pre-determined analytical goal of 6%. Twenty youth swimmers completed a 100m swim in a 25m pool, swimming breaststroke freestyle gold wearing the TritonWear ® device, whilst being white filmed Above and below water with three cameras. 95% limits of agreement (95% LoA) and coefficient of variation (% CV) were used to calculate error. Systematic biases ( P <0.05) were found between the two systems only for distance per stroke during breaststroke. Freestyle metrics agreement ranked between 1.06% and 10.40% CV, except for distance per stroke (CV = 14.64%), and time underwater (CV = 18.15%). Breaststroke metrics ranked between 0.95% and 13.74% CV, except for time underwater (CV = 25.76%). The smallest errors were found for split-times, speed, stroke-count and stroke-rate, across both strokes (all <5% CV). The TritonWear ® can be used for basic metrics of performance, Such As split-time speed and aim the error of more complex measurements, Such As time underwater gold turn-times, render em Unable to Identify typical exchange performance

    The validity of a head-worn inertial sensor for measurements of swimming performance

    Get PDF
    The validity of the TritonWear® device to measure swimming performance was investigated, with a pre-determined analytical goal of 6%. Twenty youth swimmers completed a 100 m swim in a 25 m pool, swimming breaststroke or freestyle wearing the TritonWear® device, whilst being filmed above and below water with three cameras. 95% Limits of Agreement (95% LoA) and coefficient of variation (CV%) were used to calculate error. Systematic biases (P < 0.05) were found between the two systems only for distance per stroke during breaststroke. Freestyle metrics agreement ranged between 1.06 % and 10.40 % CV, except for distance per stroke (CV = 14.64 %), and time underwater (CV = 18.15 %). Breaststroke metrics ranged between 0.95 % and 13.74 % CV, except for time underwater (CV = 25.76 %). The smallest errors were found for split-times, speed, stroke-count and stroke-rate, across both strokes (all < 5% CV). The TritonWear® can be used for basic metrics of performance, such as split-time and speed but the error of more complex measurements, such as time underwater or turn-times, renders them unable to identify typical performance changes

    Prediction of leak flow rate in plastic water distribution pipes using vibro-acoustic measurements

    Get PDF
    Leakage from water distribution systems is a worldwide issue with consequences including loss of revenue, health and environmental concerns. Leaks have typically been found through leak noise correlation by placing sensors either side of the leak and recording and analysing its vibro-acoustic emission. While this method is widely used to identify the location of the leak, the sensors also record data that could be related to the leak’s flow rate, yet no reliable method exists to predict leak flow rate in water distribution pipes using vibro-acoustic emission. The aim of this research is to predict leak flow rate in medium-density polyethylene pipe using vibro-acoustic emission signals. A novel experimental methodology is presented whereby circular holes of four sizes are tested at several leak flow rates. Following the derivation of a number of features, least squares support vector machines are used in order to predict leak flow rate. The results show a strong correlation highlighting the potential of this technique as a rapid and practical tool for water companies to assess and prioritise leak repair

    Conformational Altered p53 as an Early Marker of Oxidative Stress in Alzheimer's Disease

    Get PDF
    In order to study oxidative stress in peripheral cells of Alzheimer's disease (AD) patients, immortalized lymphocytes derived from two peculiar cohorts of patients, referring to early onset AD (EOSAD) and subjects harboured AD related mutation (ADmut), were used. Oxidative stress was evaluated measuring i) the typical oxidative markers, such as HNE Michel adducts, 3 Nitro-Tyrosine residues and protein carbonyl on protein extracts, ii) and the antioxidant capacity, following the enzymatic kinetic of superoxide dismutase (SOD), glutathione peroxidase (GPx) and glutathione reductase (GRD). We found that the signs of oxidative stress, measured as oxidative marker levels, were evident only in ADmut but not in EOSAD patients. However, oxidative imbalance in EOSAD as well as ADmut lymphocytes was underlined by a reduced SOD activity and GRD activity in both pathological groups in comparison with cells derived from healthy subjects. Furthermore, a redox modulated p53 protein was found conformational altered in both EOSAD and ADmut B lymphocytes in comparison with control cells. This conformational altered p53 isoform, named “unfolded p53”, was recognized by the use of two specific conformational anti-p53 antibodies. Immunoprecipitation experiments, performed with the monoclonal antibodies PAb1620 (that recognizes p53wt) and PAb240 (that is direct towards unfolded p53), and followed by the immunoblotting with anti-4-hydroxynonenal (HNE) and anti- 3-nitrotyrosine (3NT) antibodies, showed a preferential increase of nitrated tyrosine residues in unfolded p53 isoform comparing to p53 wt protein, in both ADmut and EOSAD. In addition, a correlation between unfolded p53 and SOD activity was further found. Thus this study suggests that ROS/RNS contributed to change of p53 tertiary structure and that unfolded p53 can be considered as an early marker of oxidative imbalance in these patients
    • …
    corecore