12 research outputs found

    Physico-chemical, mechanical and histological characteristics on rumen and reticulum of sheep submitted to different techniques of retanning

    Get PDF
    The objective was to evaluate the physicochemical, mechanical and histological characteristics on rumen and reticulum of sheep submitted to different retanning techniques. Twenty rumens and reticulum were tanned with chrome and retanned with different tannins (Treatment1 = chrome; Treatment2 = vegetable; Treatment3 = synthetic and Treatment4 = vegetable + synthetic). Tanned samples of rumens and reticulum were extracted to evaluate the arrangement of fibers, and submitted for determination of chrome oxide, substances extractable with dichloromethane, pH value and difference figure of aqueous extract. Thickness, traction resistance, elongation and progressive tearing were measured. Retanning with chrome provided greater traction resistance (3.47 N mm-2), elongation (92.76%) and progressive tearing (28.81 N mm-1). Retanning with synthetic tannins showed less traction resistance (2.68 N mm-2) and increased thickness (1.25 mm). The rumen presented better results for tensile strength and progressive tearing. Elasticity results did not differ for both rumen and reticulum. Both rumen and reticulum retanned with chrome salts showed higher levels of chrome oxide and substances extractable by Dichloromethane (34.2%). Therefore, the best results were obtained for rumen retanned with chrome salts

    Proyecto, investigación e innovación en urbanismo, arquitectura y diseño industrial

    Get PDF
    Actas de congresoLas VII Jornadas de Investigación “Encuentro y Reflexión” y I Jornadas de Investigación de becarios y doctorandos. Proyecto, investigación e innovación en Urbanismo, Arquitectura y Diseño Industrial se centraron en cuatro ejes: el proyecto; la dimensión tecnológica y la gestión; la dimensión social y cultural y la enseñanza en Arquitectura, Urbanismo y Diseño Industrial, sustentados en las líneas prioritarias de investigación definidas epistemológicamente en el Consejo Asesor de Ciencia y Tecnología de esta Universidad Nacional de Córdoba. Con el objetivo de afianzar continuidad, formación y transferencia de métodos, metodología y recursos se incorporó becarios y doctorandos de los Institutos de investigación. La Comisión Honoraria la integraron las tres Secretarias de Investigación de la Facultad, arquitectas Marta Polo, quien fundó y María del Carmen Franchello y Nora Gutiérrez Crespo quienes continuaron la tradición de la buena práctica del debate en la cotidianeidad de la propia Facultad. Los textos que conforman las VII Jornadas son los avances y resultados de las investigaciones realizadas en el bienio 2016-2018.Fil: Novello, María Alejandra. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Repiso, Luciana. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Mir, Guillermo. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Brizuela, Natalia. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Herrera, Fernanda. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Períes, Lucas. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Romo, Claudia. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Gordillo, Natalia. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; ArgentinaFil: Andrade, Elena Beatriz. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; Argentin

    Voltammetric determination of herbicide molinate in river water and rice samples using solid silver amalgam electrode fabricated with nanoparticles

    No full text
    <p>The evaluation of the voltammetric behaviour and the determination of herbicide molinate were performed for the first time over the surface of solid amalgam electrode fabricated with silver nanoparticles using cyclic voltammetry and square-wave voltammetry techniques. The experimental and instrumental parameters were evaluated to reach the maximum analytical response for molinate. It was achieved when a medium composed of 0.04 mol L<sup>−1</sup> Britton–Robinson buffer at the pH value of 4.0 was used. Under these conditions, molinate showed one pronounced reduction peak at <i>E</i><sub>p</sub> = −0.37 V (vs. Ag/AgCl 3 mol L<sup>−1</sup>) that was characterised as an irreversible system. An analytical curve was constructed at the concentration range from 9.36 to 243.49 µg L<sup>−1</sup> and a limit of detection of 2.34 µg L<sup>−1</sup> was obtained. The amalgam electrode presented good stability during the measurements with relative standard deviation (RSD) values of 2.9% for the repeatability and 5.4% for the reproducibility. The voltammetric method developed here could be conveniently applied for the determination of molinate in river water and rice spiked samples at levels below those established on the legislations of European Union and Brazil with good accuracy (RSD of less than 5% for all samples). Comparison with HPLC technique was carried out and the results indicated satisfactory concordance. According to the results depicted here, the silver nanoparticles solid amalgam electrode showed itself highly sensitive and an interesting alternative for the routine analysis of molinate in water and food samples. Furthermore, it introduces an environmentally acceptable alternative to the mercury electrodes, most commonly used for determination of reducible pesticides.</p

    Análise da evolução do número de patentes relacionadas ao processo de ordenha

    No full text
    Resumo A economia leiteira abrange produtos de grande destaque para o agronegócio brasileiro. Sua produção apresentou crescimento nas últimas décadas, podendo atribuir-se a fatores, como o aumento do número de vacas ordenhadas e/ou adoção de animais com maior produtividade no rebanho, e a inserção de tecnologia no processo de produção leiteira. Assim, o objetivo deste trabalho foi quantificar, junto à base de dados do Instituto Nacional da Propriedade Industrial – INPI, a totalidade de registros de patentes vinculadas à atividade da produção leiteira, principalmente durante a fase de ordenha, verificando se há correlação entre o número de registros e o aumento de produtividade e/ou o aumento do número de animais em lactação. Foram consultadas na base de dados do INPI, registros de patentes relacionadas ao processo de ordenha realizadas no período entre 1975 e 2015 No ano de 1996, foi promulgada a Lei n.º 9.279, que garante os direitos e obrigações relativos à propriedade industrial, momento em que ocorre maior procura pelos pedidos de registros. Entretanto, o número de pedidos de registros não foi significativo, se comparado com o período após 2006, quando entrou em vigor no Brasil a Instrução Normativa 51, que regula todo o processo envolvido na produção leiteira, quando, então, ocorreu um aumento expressivo do número de registros na base de dados do INPI. Concluiu-se, assim, que o aumento do número de patentes no período analisado coincidiu com o aumento da produção de leite, relacionado ao maior número de animais ordenhados e / ou maior produção de leite no rebanho brasileiro, o que torna a evolução tecnológica no setor ser mencionada como uma das causas da melhoria da qualidade dos produtos lácteos

    Sensibilidade e especificidade do exame eletrocardiográfico na detecção de sobrecargas atriais e/ou ventriculares em gatos da raça Persa com cardiomiopatia hipertrófica

    No full text
    Resumo: A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. O ecocardiograma é o melhor meio diagnóstico não invasivo para a diferenciação das cardiomiopatias e é considerado padrão ouro para a detecção de hipertrofia ventricular presente na CMH. Alterações eletrocardiográficas também são comuns em animais com CMH e o eletrocardiograma (ECG) é um teste de triagem para detecção de hipertrofia ventricular em humanos, sendo um exame rápido e facilmente disponível. Em gatos, poucos estudos foram realizados quanto à sensibilidade e especificidade do ECG na detecção de hipertrofia ventricular. Com a intenção de avaliar o uso do ECG como ferramenta de triagem para diagnóstico de CMH em felinos, gatos da raça Persa (n=82) foram avaliados por meio de exames ecocardiográfico e eletrocardiográfico. Animais com bloqueios e/ou distúrbios de condução foram excluídos da análise estatística (n=22). Posteriormente, os animais incluídos foram classificados em: normais (n=38), suspeitos (n=6) e acometidos pela CMH (n=16). Observaram-se diferenças estatísticas na amplitude da onda P em DII e na amplitude de onda R em DII, CV6LL e CV6LU, com valores maiores nos animais com CMH; e nos valores ecocardiográficos de velocidade e gradiente de pressão do fluxo aórtico, diâmetro do átrio esquerdo (AE) e relação AE/Ao, com valores maiores nos gatos com CMH. Dentre os animais com alterações eletrocardiográficas sugestivas de sobrecarga atrial esquerda (n=7), apenas dois realmente apresentavam aumento do AE no ecocardiograma; e dentre os animais com aumento atrial esquerdo ao ecocardiograma (n=7), apenas dois apresentavam alterações eletrocardiográficas sugestivas de sobrecarga do AE (sensibilidade de 40,40% e especificidade de 90,90%). Dentre os gatos com alterações eletrocardiográficas sugestivas de sobrecarga ventricular esquerda (n=6), cinco realmente apresentavam hipertrofia ventricular ao ecocardiograma; e dentre os animais com CMH ao ecocardiograma (n=16), apenas cinco apresentaram alterações eletrocardiográficas sugestivas de sobrecarga do VE (sensibilidade de 31,25% e especificidade de 97,72%). Observou-se correlação positiva entre espessura diastólica do septo interventricular e/ou da parede livre do ventrículo esquerdo e a amplitude da onda R em derivações DII e CV6LU. O eletrocardiograma é um exame rápido e de fácil execução, apresenta boa especificidade na detecção de hipertrofia ventricular em felinos, porém, possui baixa sensibilidade, com grande número de falsos negativos. Desta forma, o ECG auxilia no diagnóstico, mas não substitui o ecocardiograma na confirmação da hipertrofia ventricular
    corecore