31 research outputs found

    Subjective satisfaction in long-term orthokeratology patients

    Get PDF
    Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of visual distortion being graded on a scale of 0 to 10, where 0 indicated no discomfort at all. Results: More than 50% of patients skipped lens wear at least 1 night per week. The most common wearing pattern was 6–8 hours a day for 72.7% with 54.5% of patients wearing lenses every 2–3 nights only. Subjective vision scores after lens removal was 9.1 6 1.1 after having worn the lenses and 8.1 6 1.4 after skipping lens wear for 1 night. Subjective vision scores before lens insertion at the end of the day was 6.9 6 2.0 and 5.8 6 2.4, respectively. The number of hours until noticeable blur reduced with increased level of baseline myopia (r = 0.396; P , 0.001). Conclusion: Orthokeratology patients show an irregular wearing pattern after 1 year of treatment that has significant effects on the subjective visual performance over the next day of skipping lens wear. Light distortion under low-light conditions seems to be a transient complication of the treatment and most of the patients report an improvement after the first weeks of treatment.Supported in part by projects PTDC/SAU-BEB/098391/2008//FCOMP-01-0124-FEDER-010897 and PTDC/SAU-BEB/098392/2008//FCOMP-01-0124-FEDER-010898 funded by Fundacao para a Ciencia e Tecnologia (FCT) of Portugal

    Effects of ageing on the anterior segment of the eye structure and function

    Get PDF
    [Excerpt] The world will soon have more aged people than children and more people at extreme old age than ever before [1]. Improving quality of life as well as reducing severe disability due to age-related problems has become key for the health systems worldwide. The ageing of the world population has both structural and functional consequences for the human visual system; changes due to ageing occur in all the structures of the eye causing a variety of effects. Over the last few years, great advances in ophthalmic instrumentation allow the determination of ocular parameters to a level of detail without precedent. Such advances allowresearcherstodevelopspecificdevicesforvisualcorrection and rehabilitation and at the same time guide the clinicians in their decision making and selection of treatment options to convey with the increasing demand of highquality outcomes of the ageing population. This special issue aimed at creating a multidisciplinary forum of discussion on recent advances in the knowledge of the effects of ageing in the anterior segment of the human eye’s structure and function, and improvements on early detection, treatment, and prognosis of age-related ocular conditions of the anterior segment. As a result, a remarkable compilation of ten articles cover many of these very different aspects of ocular ageing. [...]info:eu-repo/semantics/publishedVersio

    Collyria seals in the Roman Empire

    Get PDF
    Roman seals associated with collyria (Latin expression for eye drops /washes and lotions for eye maintenance) provide valuable information about eye care in the antiquity. These small, usually stone-made pieces bore engravings with the names of eye doctors and also the collyria used to treat an eye disease. The collyria seals have been found all over the Roman empire and Celtic territories in particular and were usually associated with military camps. In Hispania (Iberian Peninsula), only three collyria seals have been found. These findings speak about eye care in this ancient Roman province as well as about of the life of the time. This article takes a look at the utility and social significance of the collyria seals and seeks to give an insight in the ophthalmological practice of in the Roman Empire

    PEČATI ZA KOLIRIJE U RIMSKOM CARSTVU

    Get PDF
    Roman seals associated with collyria (Latin expression for eye drops /washes and lotions for eye maintenance) provide valuable information about eye care in the antiquity. These small, usually stone-made pieces bore engravings with the names of eye doctors and also the collyria used to treat an eye disease. The collyria seals have been found all over the Roman empire and Celtic territories in particular and were usually associated with military camps. In Hispania (Iberian Peninsula), only three collyria seals have been found. These findings speak about eye care in this ancient Roman province as well as about of the life of the time. This article takes a look at the utility and social significance of the collyria seals and seeks to give an insight in the ophthalmological practice of in the Roman Empire.Rimski pečati kojima su se pečatili koliriji (lat. collyrium – kapi, losioni, voda za oči) daju vrijedan uvid u postupke njege i liječenja očiju u antička vremena. U ove su se male kamene pečate obično gravirala imena očnih liječnika i naziv kolirija koji se rabio za pojedinu očnu bolest. Pečati za kolirije pronađeni su posvuda u Rimskom Carstvu, a ponajviše na okupiranim keltskim teritorijima i to u vojnim logorima. U Hispaniji (na Iberijskom poluotoku) pronađena su tek tri takva pečata. Ovi nam nalazi govore o njezi očiju u ovoj staroj rimskoj provinciji i o životu u to doba. Cilj je članka razmotriti korisnost i društvenu važnost pečata za kolirije i pružiti čitatelju uvid u oftalmološku praksu u Rimskom Carstvu

    Glial metabolic alterations during glaucoma pathogenesis

    Get PDF
    Glaucoma is the leading cause of irreversible blindness. Current treatment options are limited and often only slow disease progression. Metabolic dysfunction has recently been recognized as a key early and persistent mechanism in glaucoma pathophysiology. Several intrinsic metabolic dysfunctions have been identified and treated in retinal ganglion cells to provide neuroprotection. Growing pre-clinical and clinical evidence has confirmed that metabolic alterations in glaucoma are widespread, occurring across visual system tissues, in ocular fluids, in blood/serum, and at the level of genomic and mitochondrial DNA. This suggests that metabolic dysfunction is not constrained to retinal ganglion cells and that metabolic alterations extrinsic to retinal ganglion cells may contribute to their metabolic compromise. Retinal ganglion cells are reliant on glial metabolic support under normal physiological conditions, but the implications of metabolic dysfunction in glia are underexplored. We highlight emerging evidence that has demonstrated metabolic alterations occurring within glia in glaucoma, and how this may affect neuro-glial metabolic coupling and the metabolic vulnerability of retinal ganglion cells. In other neurodegenerative diseases which share features with glaucoma, several other glial metabolic alterations have been identified, suggesting that similar mechanisms and therapeutic targets may exist in glaucoma

    Nicotinamide provides neuroprotection in glaucoma by protecting against mitochondrial and metabolic dysfunction.

    Get PDF
    Nicotinamide adenine dinucleotide (NAD) is a REDOX cofactor and metabolite essential for neuronal survival. Glaucoma is a common neurodegenerative disease in which neuronal levels of NAD decline. We assess the effects of nicotinamide (a precursor to NAD) on retinal ganglion cells (the affected neuron in glaucoma) in normal physiological conditions and across a range of glaucoma relevant insults including mitochondrial stress and axon degenerative insults. We demonstrate retinal ganglion cell somal, axonal, and dendritic neuroprotection by nicotinamide in rodent models which represent isolated ocular hypertensive, axon degenerative, and mitochondrial degenerative insults. We performed metabolomics enriched for small molecular weight metabolites for the retina, optic nerve, and superior colliculus which demonstrates that ocular hypertension induces widespread metabolic disruption, including consistent changes to α-ketoglutaric acid, creatine/creatinine, homocysteine, and glycerophosphocholine. This metabolic disruption is prevented by nicotinamide. Nicotinamide provides further neuroprotective effects by increasing oxidative phosphorylation, buffering and preventing metabolic stress, and increasing mitochondrial size and motility whilst simultaneously dampening action potential firing frequency. These data support continued determination of the utility of long-term nicotinamide treatment as a neuroprotective therapy for human glaucoma

    Visual fatigue during control room work in process industries

    No full text
    BACKGROUND: Working in front of computer screens is visually demanding and related to adverse eye symptoms. Occurrence of glare further increases visual fatigue. OBJECTIVE: This paper presents results from an examination of visual ergonomics in control room environments at two Swedish process industries. METHODS: Visual conditions were examined and evaluated in nine control rooms and eighteen process operators answered questions about their perceived workload and visual experiences. RESULTS: When working in the control rooms, the mental workload was rated significantly higher by the participants, compared to experienced performance. The operators further experienced significantly higher visual fatigue and blurred vision compared to double vision and sore eyes. Visual demands were increased in conditions where contrast glare was present, as well as frequent changes of focusing distances, and low contrast between background and characters in computer screens. CONCLUSIONS: Suboptimal visual working conditions in the control rooms contributes to increased visual demands on the operators. Presence of glare is leading to visual fatigue and an unnecessary high mental load. The findings support the relevance of considering principles of general and visual ergonomics when designing and organizing work in control rooms. Workstation design should also be flexible to allow for individual and contextual adjustments

    Repeatability of quantitative measurements of retinal layers with SD-OCT and agreement between vertical and horizontal scan protocols in healthy eyes.

    No full text
    PurposeTo evaluate the repeatability of the new spectral domain optical coherence tomography (HOCT-1F), and also to evaluate the agreement between vertical and horizontal scan protocols. In addition, we also evaluated the relation between the repeatability and age.MethodsThree consecutive measurements of the inner limiting membrane-retinal pigment epithelium (ILM-RPE), inner limiting membrane-inner plexiform layer (ILM-IPL) from macular horizontal and vertical scans, and inner limiting membrane-retinal nerve fiber layer (ILM-RNFL) from optic disc horizontal scan. 159 subjects were included in the analysis. The within subject standard deviation (Sw) and the repeatability limits (Rlimit) are used to represent the repeatability of the parameters for the different sectors.ResultsThe Sw for the ILM-RPE thickness was less than 3.5 μm for each sector and scan direction. The Sw values varied within the sectors and scan modes, with horizontal scan modes resulting in better values for the horizontal sectors, and vice versa. The Sw for the GCL-IPL thickness was less than 2 μm, and was similar between the vertical and horizontal scan modes for each sector map. For the optic disc scan, the Sw was not symmetric along the clock-hour map sectors, the largest Sw values were seen in the vertical sectors (8.6 μm). The mean difference between the vertical and horizontal scans was less than 2 μm for each retinal thickness sector map. Significant but weak correlation between the Sw and the subject's age was seen in both macular and optic disc scans.ConclusionsThe repeatability of the HOCT-1F to measure the ILM-RPE-, ILM-IPL- and ILM-RNFL-thickness is good. The repeatability of the ILM-RPE thickness is dependent on the scan direction, which should be taken into account when calculating retinal thickness. There is a weak correlation between the repeatability and the subject's age

    Effect of Instrument Design and Technique on the Precision and Accuracy of Objective Refraction Measurement

    No full text
    Background: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. Results: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. Conclusion: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction

    Prophylactic nicotinamide treatment protects from rotenone-induced neurodegeneration by increasing mitochondrial content and volume

    No full text
    Abstract Leber’s hereditary optic neuropathy (LHON) is driven by mtDNA mutations affecting Complex I presenting as progressive retinal ganglion cell dysfunction usually in the absence of extra-ophthalmic symptoms. There are no long-term neuroprotective agents for LHON. Oral nicotinamide provides a robust neuroprotective effect against mitochondrial and metabolic dysfunction in other retinal injuries. We explored the potential for nicotinamide to protect mitochondria in LHON by modelling the disease in mice through intravitreal injection of the Complex I inhibitor rotenone. Using MitoV mice expressing a mitochondrial-tagged YFP in retinal ganglion cells we assessed mitochondrial morphology through super-resolution imaging and digital reconstruction. Rotenone induced Complex I inhibition resulted in retinal ganglion cell wide mitochondrial loss and fragmentation. This was prevented by oral nicotinamide treatment. Mitochondrial ultrastructure was quantified by transition electron microscopy, demonstrating a loss of cristae density following rotenone injection, which was also prevented by nicotinamide treatment. These results demonstrate that nicotinamide protects mitochondria during Complex I dysfunction. Nicotinamide has the potential to be a useful treatment strategy for LHON to limit retinal ganglion cell degeneration
    corecore