462 research outputs found

    Spiral cracks in drying precipitates

    Full text link
    We investigate the formation of spiral crack patterns during the desiccation of thin layers of precipitates in contact with a substrate. This symmetry-breaking fracturing mode is found to arise naturally not from torsion forces, but from a propagating stress front induced by the fold-up of the fragments. We model their formation mechanism using a coarse-grain model for fragmentation and successfully reproduce the spiral cracks. Fittings of experimental and simulation data show that the spirals are logarithmic, corresponding to constant deviation from a circular crack path. Theoretical aspects of the logarithmic spirals are discussed. In particular we show that this occurs generally when the crack speed is proportional to the propagating speed of stress front.Comment: 4 pages, 5 figures, RevTe

    An in vivo study of the host response to starch-based polymers and composites subcutaneously implanted in rats

    Get PDF
    Implant failure is one of the major concerns in the biomaterials field. Several factors have been related to the fail but in general these biomaterials do not exhibit comparable physical, chemical or biological properties to natural tissues and ultimately, these devices can lead to chronic inflammation and foreign-body reactions. Starch-based biodegradable materials and composites have shown promising properties for a wide range of biomedical applications as well as a reduced capacity to elicit a strong reaction from immune system cells in vitro. In this work, blends of corn starch with ethylene vinyl alcohol (SEVA-C), cellulose acetate (SCA) and polycaprolactone (SPCL), as well as hydroxyapatite (HA) reinforced starch-based composites, were investigated in vivo. The aim of the work was to assess the host response evoked for starch-based biomaterials, identifying the presence of key cell types. The tissues surrounding the implant were harvested together with the material and processed histologically for evaluation using immunohistochemistry. At implant retrieval there was no cellular exudate around the implants and no macroscopic signs of an inflammatory reaction in any of the animals. The histological analysis of the sectioned interface tissue after immunohistochemical staining using ED1, ED2, CD54, MHC class II and a/b antibodies showed positively stained cells for all antibodies, except for a/b for all the implantation periods, where it was different for the various polymers and for the period of implantation. SPCL and SCA composites were the materials that stimulated the greatest cellular tissue responses, but generally biodegradable starch-based materials did not induce a severe reaction for the studied implantation times, which contrasts with other types of degradable polymeric biomaterials.Fundação para a Ciência e a Tecnologia (FCT

    Time-dependent failure in load-bearing polymers: a potential hazard in structural applications of polylactides

    Get PDF
    With their excellent biocompatibility and relatively high mechanical strength, polylactides are attractive candidates for application in load-bearing, resorbable implants. Pre-clinical studies provided a proof of principle for polylactide cages as temporary constructs to facilitate spinal fusion, and several cages already made it to the market. However, also failures have been reported: clinical studies reported considerable amounts of subsidence with lumbar spinal fusion cages, and in an in vivo goat study, polylactide spinal cages failed after only three months of implantation, although mechanical testing had predicted sufficient strength for at least eight months. The failures appear to be related to the long-term performance of polylactides under static loading conditions, a phenomenon which is common to all glassy polymers and finds its origin in stress-activated molecular mobility leading to plastic flow. This paper reviews the mechanical properties and deformation kinetics of amorphous polylactides. Compression tests were performed with various strain rates, and static stress experiments were done to determine time-to failure. Pure PLLA appeared to have a higher yield strength than its co-polymers with d-lactide, but the kinetic behaviour of the polymers was the same: an excellent short-term strength at higher loading rates, but lifetime under static stress is rather poor. As spinal implants need to maintain mechanical integrity for a period of at least six months, this has serious implications for the clinical application of amorphous polylactides in load bearing situations. It is recommended that standards for mechanical testing of implants made of polymers be revised in order to consider this typical time-dependent behaviour

    Anterior-inferior plating of middle-third fractures of the clavicle

    Get PDF
    © The Author(s) 2009. This article is published with open access at Springerlink.com Introduction Various techniques have been reported for the treatment of middle-third clavicle (collar bone) fractures. This prospective study was conducted to evaluate the results of anterior-inferior plating using a 3.5-mm reconstruction plate for the treatment of middle-third clavicle fractures

    Biodegradable Polymers in Bone Tissue Engineering

    Get PDF
    The use ofdegradable polymers in medicine largely started around the mid 20th century with their initial use as in vivo resorbing sutures. Thorough knowledge on this topic as been gained since then and the potential applications for these polymers were, and still are, rapidly expanding. After improving the properties of lactic acid-based polymers, these were no longer studied only from a scientific point of view, but also for their use in bone surgery in the 1990s. Unfortunately, after implanting these polymers, different foreign body reactions ranging from the presence of white blood cells to sterile sinuses with resorption of the original tissue were observed. This led to the misconception that degradable polymers would, in all cases, lead to inflammation and/or osteolysis at the implantation site. Nowadays, we have accumulated substantial knowledge on the issue of biocompatibility of biodegradable polymers and are able to tailor these polymers for specific applications and thereby strongly reduce the occurrence of adverse tissue reactions. However, the major issue of biofunctionality, when mechanical adaptation is taken into account, has hitherto been largely unrecognized. A thorough understanding of how to improve the biofunctionality, comprising biomechanical stability, but also visualization and sterilization of the material, together with the avoidance of fibrotic tissue formation and foreign body reactions, may greatly enhance the applicability and safety of degradable polymers in a wide area of tissue engineering applications. This review will address our current understanding of these biofunctionality factors, and will subsequently discuss the pitfalls remaining and potential solutions to solve these problems

    Spherical calcium phosphate nanoparticle fillers allow polymer processing of bone fixation devices with high bioactivity

    Full text link
    Treatment of bone defects generally requires a fixation device. Biodegradable implants can often prevent second operations in contrast to metallic implants that are surgically removed after healing. In this study, we investigate the preparation of a bone fixation device with additional bioactivity by adding nanoparticulate amorphous tricalcium phosphate (ATCP) to improve bonding to bone. Medically approved poly(lactide-co-glycolide) (PLGA) and spherical (ATCP) nanoparticles were blended directly or through a two-step approach, where ATCP was first dispersed in PLGA by solvent casting, extruded and hot pressed producing blocks and bone screws. The latter route yielded good particle dispersion while blending alone led to inhomogeneous mixtures. Samples were immersed in simulated body fluid and showed rapid formation of surface hydroxyapatite layers (examined by X-ray diffraction and scanning electron microscopy) already after 3 days, thus confirming very high bioactivity. Polymer degradation during processing and upon simulated implantation conditions was followed by gel permeation chromatography. The elevated temperature during extrusion was the strongest single factor contributing to PLGA degradation. Screws could be machined out of extruded cylinders and demonstrated the ability to process PLGA/ATCP 90/10 composites with regular workshop tools. These properties suggest the use of such composites as improved, bioactive, and degradable bone fixation systems particularly in oral and maxillofacial surgery. POLYM. ENG. SCI., 50:952-960, 2010. (C) 2009 Society of Plastics Engineer

    The Evaluation of the Possibilities of Using PLGA Co-Polymer and Its Composites with Carbon Fibers or Hydroxyapatite in the Bone Tissue Regeneration Process – in Vitro and in Vivo Examinations

    Get PDF
    Synthetic polymers belonging to the aliphatic polyester group have become highly promising biomaterials for reconstructive medicine. The purpose of the present work is a biological evaluation of lactide-glycolide co-polymer (PLGA) and its composites with carbon fibers (PLGA+CF) or hydroxyapatite (PLGA+HA). The cytotoxicity of the evaluated materials towards hFOB 1.19 human osteoblast-like cells was assessed. Moreover, during the one-year contact of the assessed materials with living osseous tissue, the progress of bone formation was analyzed and the accompanying process of the materials’ degradation was evaluated. The materials under evaluation proved to be biocompatible
    corecore