564 research outputs found

    Surfactant Sensors in Biotechnology; Part 1 ā€“ Electrochemical Sensors

    Get PDF
    An overview on electrochemical surfactant sensors is given with special attention to papers published since 1993. The importance of surfactants in modern biotechnology is stressed out. Electrochemical sensors are usually divided according to the measured physical quantity to potentiometric, amperometric, conductometric and impedimetric surfactant sensors. The last ones are very few. Potentiometric surfactant sensors are the most numerous due to their simplicity and versatility. They can be used either as end-point titration sensors or as direct EMF measurement sensors, in batch or flow-through mode. Some amperometric surfactant sensors are true biosensors that use microorganisms or living cells

    Application of a New Potentiometric Sensor for Determination of Anionic Surfactants in Wastewater

    Get PDF
    A new screen-printed potentiometric microsensor (SPMS) for the determination of anionic surfactants (ASs) based on the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion pair as a sensing material was applied to real industrial effluents. The sensor is accurate, inexpensive, simple and very sensitive. The solutions of cetylpyridinium chloride (CPC) of the concentrations down to 5Ā· 10ā€“5 mol dmā€“3 were used as a titrant. Standard addition method was used for checking the precision and accuracy of measurements providing satisfactory results with recoveries between 98.3 to 102.0 % in pure AS solutions and 99.0 to 114.5 % in wastewater. Standard spectrophotometric method Methylene Blue Active Substances (MBAS) was used as control for comparison of the results obtained with the new sensor. The results obtained using SPMS were compared with those obtained by the polymeric membrane ion-selective electrodes (ISEs), containing the same sensing material, and exhibited good mutual agreement

    Positron and positronium annihilation patterns in zeolites and bulk ceramics

    Get PDF
    Positron lifetime (LT) measurements have revealed that in porous media the annihilation pattern is probably dominated by a near-saturation level trapping both for the positron and the positronium as well, which masks the contribution from the ldquofree annihilationrdquo, i.e., annihilation from delocalised positrons. In this work we compare positron lifetime spectra of crystalline zeolites with bulk ceramic materials fabricated by sintering from the same constituents as the zeolites and analyse common features and differences between them. For the dense ceramic samples the contribution from long-living components to the annihilation pattern is substantially lower than that for the zeolites. The results are analysed with the aim to extract new knowledge for the zeolites and for the sensitivity limits for free volume studies in ceramics. (Ā© 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

    24. Carotid Stiffness in Migraine

    Get PDF

    A cross-country examination on the fear of covid-19 and the sense of loneliness during the first wave of covid-19 outbreak

    Get PDF
    The aim of the current study is to examine gender, age. and cross-country differences in fear of COVID-19 and sense of loneliness during the lockdown, by comparing people from those countries with a high rate of infections and deaths (e.g., Spain and Italy) and from countries with a mild spread of infection (e.g., Croatia, Serbia, Slovakia, Slovenia, and Bosnia and Herzegovina). A total of 3876 participants (63% female) completed an online survey on ā€œEveryday life practices in COVID-19 timeā€ in April 2020, including measures of fear of COVID-19 and loneliness. Males and females of all age groups in countries suffering from the powerful impact of the COVID-19 pandemic reported greater fear of COVID-19 and sense of loneliness. In less endangered countries, females and the elderly reported more symptoms than males and the young; in Spanish and Italian samples, the pattern of differences is considerably more complex. Future research should thoroughly examine different age and gender groups. The analysis of emotional well-being in groups at risk of mental health issues may help to lessen the long term social and economic costs due to the COVID-19 outbreak

    Surfactant Sensors in Biotechnology; Part 2 ā€“ Non-Electrochemical Sensors

    Get PDF
    An overview on non-electrochemical surfactant sensors is given with special attention to work published since 1993. In the first part the importance of surfactants in modern biotechnology is stressed out and works on electrochemical surfactant sensors have been summarised. In this part the research of non-electrochemical surfactant sensors is reported, primarily optochemical and piezoelectric surfactant sensors. Papers investigating some specific interactions of potential interest for surfactant sensors are reported as well

    Search for Light Gauge Bosons of the Dark Sector at the Mainz Microtron

    Get PDF
    A new exclusion limit for the electromagnetic production of a light U(1) gauge boson {\gamma}' decaying to e^+e^- was determined by the A1 Collaboration at the Mainz Microtron. Such light gauge bosons appear in several extensions of the standard model and are also discussed as candidates for the interaction of dark matter with standard model matter. In electron scattering from a heavy nucleus, the existing limits for a narrow state coupling to e^+e^- were reduced by nearly an order of magnitude in the range of the lepton pair mass of 210 MeV/c^2 < m_e^+e^- < 300 MeV/c^2. This experiment demonstrates the potential of high current and high resolution fixed target experiments for the search for physics beyond the standard model.Comment: 4 pages, 7 figure

    Recoil polarization and beam-recoil double polarization measurement of \eta electroproduction on the proton in the region of the S_{11}(1535) resonance

    Get PDF
    The beam-recoil double polarization P_{x'}^h and P_{z'}^h and the recoil polarization P_{y'} were measured for the first time for the p(\vec{e},e'\vec{p})\eta reaction at a four-momentum transfer of Q^2=0.1 GeV^2/c^2 and a center of mass production angle of \theta = 120^\circ at MAMI C. With a center of mass energy range of 1500 MeV < W < 1550 MeV the region of the S_{11}(1535) and D_{13}(1520) resonance was covered. The results are discussed in the framework of a phenomenological isobar model (Eta-MAID). While P_{x'}^h and P_{z'}^h are in good agreement with the model, P_{y'} shows a significant deviation, consistent with existing photoproduction data on the polarized-target asymmetry.Comment: 4 pages, 1 figur

    A Large-Scale FPGA-Based Trigger and Dead-Time Free DAQ System for the Kaos Spectrometer at MAMI

    Full text link
    The Kaos spectrometer is maintained by the A1 collaboration at the Mainz Microtron MAMI with a focus on the study of (e,e'K^+) coincidence reactions. For its electron-arm two vertical planes of fiber arrays, each comprising approximately 10 000 fibers, are operated close to zero degree scattering angle and in close proximity to the electron beam. A nearly dead-time free DAQ system to acquire timing and tracking information has been installed for this spectrometer arm. The signals of 144 multi-anode photomultipliers are collected by 96-channel front-end boards, digitized by double-threshold discriminators and the signal time is picked up by state-of-the-art F1 time-to-digital converter chips. In order to minimize background rates a sophisticated trigger logic was implemented in newly developed Vuprom modules. The trigger performs noise suppression, signal cluster finding, particle tracking, and coincidence timing, and can be expanded for kinematical matching (e'K^+) coincidences. The full system was designed to process more than 4 000 read-out channels and to cope with the high electron flux in the spectrometer and the high count rate requirement of the detectors. It was successfully in-beam tested at MAMI in 2009.Comment: Contributed to 17th IEEE Real Time Conference (RT10), Lisbon, 24-28 May 201
    • ā€¦
    corecore