198 research outputs found

    Multicenter evaluation of a new electrochemiluminescence immunoassay for everolimus concentrations in whole blood

    Get PDF
    Background: The precise monitoring of everolimus, an immunosuppressant drug, is vital for transplant recipients due to its narrow therapeutic range. This study evaluated the analytical performance of a new electrochemiluminescence immunoassay (ECLIA) for everolimus concentrations in whole blood. Methods: Accuracy, imprecision, and sensitivity studies for the Roche Elecsys everolimus ECLIA were performed at 5 European laboratories. The ECLIA was compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods, as well as the Quantitative Microsphere System everolimus assay. Results: Everolimus ECLIA accuracies were within the range 100% +/- 9%. Coefficients of variation (CVs) across the target range were <= 4.8% for repeatability and <= 8.4% for intermediate imprecision, whereas multisite reproducibility at lower (2.71 mcg/L) and higher everolimus concentrations (3.0-30.0 mcg/L) resulted in CVs of <= 13.7% and <= 12.4%, respectively. The CV at the assay's lower limit of quantification without considering bias was excellent, estimated as <= 9.3% at 0.5 mcg/L. The weighted Deming regression analysis, used for comparison of the results obtained by everolimus ECLIA and by LC-MS/MS methods, yielded a slope of 1.21 [95% confidence interval (CI): 1.15-1.26], intercept of 0.478 mcg/L (95% CI: 0.241-0.716), and a Pearson correlation coefficient (r) of 0.91. A single-site comparison between the ECLIA and the Quantitative Microsphere System assay revealed a slope of 1.05 (95% CI: 0.917-1.17), intercept of 1.03 mcg/L (95% CI: 0.351-1.70), and r of 0.91. Conclusions: Based on these results, the Roche Elecsys everolimus ECLIA can be considered suitable for routine therapeutic drug monitoring. A positive bias was observed with respect to LC-MS/MS methods, suggesting that it may be necessary to rebaseline individual patients when switching from LC-MS/MS to the ECLIA; however, this must also be considered for any change of method for everolimus measurement

    The Heliophysics Feature Catalogue, a tool for the study of solar features

    Get PDF
    The behavior of filaments and prominences during the Solar Cycle is a signature of Sun's activity. It is therefore important to follow their evolution during the cycle, in order to be able to associate it with the various phases of the Solar Cycle as well as with other Solar features or events. The virtual observatory HELIO provides information that can be used for such studies, especially its Heliophysics Feature Catalogue gives a unique access to the description of various features during around one cycle. Features available are: filaments, prominences, photospheric and coronal active regions, coronal radio emission, type III radio bursts, coronal holes and sunspots. Web interfaces allow the user to query data for these features. Useful information can also be shared with other HELIO services, such as Heliophysics Event Catalogue, which provides access to dozens of tables of events such as flares, CME

    A tomographic microscopy-compatible Langendorff system for the dynamic structural characterization of the cardiac cycle

    Get PDF
    ntroduction: Cardiac architecture has been extensively investigated ex vivo using a broad spectrum of imaging techniques. Nevertheless, the heart is a dynamic system and the structural mechanisms governing the cardiac cycle can only be unveiled when investigating it as such. Methods: This work presents the customization of an isolated, perfused heart system compatible with synchrotron-based X-ray phase contrast imaging (X-PCI). Results: Thanks to the capabilities of the developed setup, it was possible to visualize a beating isolated, perfused rat heart for the very first time in 4D at an unprecedented 2.75 ÎĽm pixel size (10.6 ÎĽm spatial resolution), and 1 ms temporal resolution. Discussion: The customized setup allows high-spatial resolution studies of heart architecture along the cardiac cycle and has thus the potential to serve as a tool for the characterization of the structural dynamics of the heart, including the effects of drugs and other substances able to modify the cardiac cycle

    Influence of surgical approach on component positioning in primary total hip arthroplasty

    Get PDF
    Background: Minimal invasive surgery (MIS) has gained growing popularity in total hip arthroplasty (THA) but concerns exist regarding component malpositioning. The aim of the present study was to evaluate femoral and acetabular component positioning in primary cementless THA comparing a lateral to a MIS anterolateral approach. Methods: We evaluated 6 week postoperative radiographs of 52 hips with a minimal invasive anterolateral approach compared to 54 hips with a standard lateral approach. All hips had received the same type of implant for primary cementless unilateral THA and had a healthy hip contralaterally. Results: Hip offset was equally restored comparing both approaches. No influence of the approach was observed with regard to reconstruction of acetabular offset, femoral offset, vertical placement of the center of rotation, stem alignment and leg length discrepancy. However, with the MIS approach, a significantly higher percentage of cups (38.5 %) was malpositioned compared to the standard approach (16.7 %) (p = 0.022). Conclusions: The MIS anterolateral approach allows for comparable reconstruction of stem position, offset and center of rotation compared to the lateral approach. However, surgeons must be aware of a higher risk of cup malpositioning for inclination and anteversion using the MIS anterolateral approach

    Technology roadmap for cold-atoms based quantum inertial sensor in space

    Get PDF
    Recent developments in quantum technology have resulted in a new generation of sensors for measuring inertial quantities, such as acceleration and rotation. These sensors can exhibit unprecedented sensitivity and accuracy when operated in space, where the free-fall interrogation time can be extended at will and where the environment noise is minimal. European laboratories have played a leading role in this field by developing concepts and tools to operate these quantum sensors in relevant environment, such as parabolic flights, free-fall towers, or sounding rockets. With the recent achievement of Bose-Einstein condensation on the International Space Station, the challenge is now to reach a technology readiness level sufficiently high at both component and system levels to provide "off the shelf"payload for future generations of space missions in geodesy or fundamental physics. In this roadmap, we provide an extensive review on the status of all common parts, needs, and subsystems for the application of atom-based interferometers in space, in order to push for the development of generic technology components

    Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

    Get PDF
    A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe

    Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Get PDF
    The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 ÎĽ\mum thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 3â‹…10153 \cdot 10^{15} neq/cm2^2. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations

    The CMS Phase-1 pixel detector upgrade

    Get PDF
    The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.Peer reviewe

    Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

    Get PDF
    The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment's silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to Phi(eq) = 2x10(16) cm(-2), and an ionising dose of approximate to 5 MGy after an integrated luminosity of 3000 fb(-1). Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 mu m thick p-bulk pad diodes and strip sensors irradiated up to fluences of Phi(eq) = 1.3 x 10(16) cm(-2) are shown.Peer reviewe
    • …
    corecore