851 research outputs found
Analysis of heavy spin--3/2 baryon--heavy spin--1/2 baryon--light vector meson vertices in QCD
The heavy spin--3/2 baryon--heavy spin--1/2 baryon vertices with light vector
mesons are studied within the light cone QCD sum rules method. These vertices
are parametrized in terms of three coupling constants. These couplings are
calculated for all possible transitions. It is shown that correlation functions
for these transitions are described by only one invariant function for every
Lorenz structure. The obtained relations between the correlation functions of
the different transitions are structure independent while explicit expressions
of invariant functions depend on the Lorenz structure.Comment: 17 Pages, 6 Figures and 4 Table
Thymomas: a review.
Thymomas are neoplasma of thymic epithelial cells. They may be benign or malignant and may
associate with locai ìnvasiveness and paraneoplastic diseases. Myasthenia gravis is often
associated with thymomas, bui this is not thè rule. Several classifications have been proposed:
some of them follow thè histopathological findings (Rosai and Levine, Snover, Marino and Muller-
Hermelink classification), other emphasizes thè clinic-pathological stage (Masaoka, Verley and
Hollmann stadiation). One third of thymomas is asymptomatic. Diagnosis is made often by plain
X-ray and confirmed by Computed Tomography or fine needle biopsy. Surgery is effective in 100%
of noninvasive cases and in 58% of invasive ones. Radio and chemotherapy are recommended
only in advanced or inoperable stages
The 4 K outer cryostat for the CUORE experiment: construction and quality control
The external shell of the CUORE cryostat is a large cryogen-free system
designed to host the dilution refrigerator and the bolometers of the CUORE
experiment in a low radioactivity environment. The three vessels that form the
outer shell were produced and delivered to the Gran Sasso underground
Laboratories in July 2012. In this paper, we describe the production techniques
and the validation tests done at the production site in 2012.Comment: 11 pages, 13 figures; to appear in NIM
Searches for axioelectric effect of solar axions with BGO-scintillator and BGO-bolometer detectors
A search for axioelectric absorption of 5.5 MeV solar axions produced in the
reaction has been
performed with a BGO detectors. A model-independent limit on the product of
axion-nucleon and axion-electron coupling constants has
been obtained: for 90\% C.L..Comment: 5 pages, 3 figures, Proceedings of the 10th Patras Workshop on
Axions, WIMPs and WISP 29 June - 4 July 2014, CERN, Geneva, Switzerlan
The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors
The cryogenic underground observatory for rare events (CUORE) is a 1-ton
scale bolometric experiment whose detector consists of an array of 988 TeO2
crystals arranged in a cylindrical compact structure of 19 towers. This will be
the largest bolometric mass ever operated. The experiment will work at a
temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free
system based on pulse tubes and a custom high power dilution refrigerator,
designed to match these specifications. The cryostat has been commissioned in
2014 at the Gran Sasso National Laboratories and reached a record temperature
of 6 mK on a cubic meter scale. In this paper, we present results of CUORE
commissioning runs. Details on the thermal characteristics and cryogenic
performances of the system will be also given.Comment: 7 pages, 2 figures, LTD16 conference proceedin
Routine serum biomarkers, but not dual-energy X-ray absorptiometry, correlate with cortical bone mineral density in children and young adults with chronic kidney disease
BACKGROUND: Biomarkers and dual-energy X-ray absorptiometry (DXA) are thought to be poor predictors of bone mineral density (BMD). The Kidney Disease: Improving Global Outcomes guidelines suggest using DXA if the results will affect patient management, but this has not been studied in children or young adults in whom bone mineral accretion continues to 30 years of age. We studied the clinical utility of DXA and serum biomarkers against tibial cortical BMD (CortBMD) measured by peripheral quantitative computed tomography, expressed as Z-score CortBMD, which predicts fracture risk. METHODS: This was a cross-sectional multicentre study in 26 patients with CKD4 and 5 and 77 on dialysis. RESULTS: Significant bone pain that hindered activities of daily living was present in 58%, and 10% had at least one low-trauma fracture. CortBMD and cortical mineral content Z-scores were lower in dialysis compared with CKD patients (P = 0.004 and P = 0.02). DXA BMD hip and lumbar spine Z-scores did not correlate with CortBMD or biomarkers. CortBMD was negatively associated with parathyroid hormone (PTH; r = -0.44, P < 0.0001) and alkaline phosphatase (ALP; r = -0.22, P = 0.03) and positively with calcium (Ca; r = 0.33, P = 0.001). At PTH <3 times upper limit of normal, none of the patients had a CortBMD below -2 SD (odds ratio 95% confidence interval 7.331 to infinity). On multivariable linear regression PTH (β = -0.43 , P < 0.0001), ALP (β = -0.36, P < 0.0001) and Ca (β = 0.21, P = 0.005) together predicted 57% of variability in CortBMD. DXA measures did not improve this model. CONCLUSIONS: Taken together, routinely used biomarkers, PTH, ALP and Ca, but not DXA, are moderate predictors of cortical BMD. DXA is not clinically useful and should not be routinely performed in children and young adults with CKD 4-5D
First array of enriched ZnSe bolometers to search for double beta decay
The R&D activity performed during the last years proved the potential of ZnSe
scintillating bolometers to the search for neutrino-less double beta decay,
motivating the realization of the first large-mass experiment based on this
technology: CUPID-0. The isotopic enrichment in Se, the ZnSe
crystals growth, as well as the light detectors production have been
accomplished, and the experiment is now in construction at Laboratori Nazionali
del Gran Sasso (Italy). In this paper we present the results obtained testing
the first three ZnSe crystals operated as scintillating bolometers, and
we prove that their performance in terms of energy resolution, background
rejection capability and intrinsic radio-purity complies with the requirements
of CUPID-0
CUPID-0: the first array of enriched scintillating bolometers for 0decay investigations
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of82Se neutrinoless double-beta decay (0). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0at the level of 10- 3 counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn82Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
We report the results of a search for axions from the 14.4 keV M1 transition
from Fe-57 in the core of the sun using the axio-electric effect in TeO2
bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a
facility used to test bolometers for the CUORE experiment at the Laboratori
Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made
using a newly developed low energy trigger which was optimized to reduce the
detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established
at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the
Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the
flavor-singlet axial vector matrix element. Bounds are given for the interval
0.15 < S < 0.55.Comment: 14 pages, 6 figures, submitted to JCA
- …