98 research outputs found

    The LifeV library: engineering mathematics beyond the proof of concept

    Get PDF
    LifeV is a library for the finite element (FE) solution of partial differential equations in one, two, and three dimensions. It is written in C++ and designed to run on diverse parallel architectures, including cloud and high performance computing facilities. In spite of its academic research nature, meaning a library for the development and testing of new methods, one distinguishing feature of LifeV is its use on real world problems and it is intended to provide a tool for many engineering applications. It has been actually used in computational hemodynamics, including cardiac mechanics and fluid-structure interaction problems, in porous media, ice sheets dynamics for both forward and inverse problems. In this paper we give a short overview of the features of LifeV and its coding paradigms on simple problems. The main focus is on the parallel environment which is mainly driven by domain decomposition methods and based on external libraries such as MPI, the Trilinos project, HDF5 and ParMetis. Dedicated to the memory of Fausto Saleri.Comment: Review of the LifeV Finite Element librar

    Thermoplastic Materials for the Metal Replacement of Non-Structural Components in Marine Engines

    Get PDF
    Metal replacements for automotive and aerospace components are already a consolidated reality, in light of the advantages offered by fibre-reinforced polymers, consisting of reduced costs, weight, and environmental impact. As a result, engineering has been studying the possibility of replacing currently used metallic alloys with alternative materials, such as thermoplastic fibre-reinforced polymers, in the manufacturing of non-structural sections of marine engines. Given the peculiar characteristics of the working environment of such parts, i.e., ship engine spaces, and the strict requirements regarding safety, the selection of the polymer must be properly performed through a tailored material design process. Consequently, the redesign of the components must be carried out with the aim of exploiting the best of the materials’ properties while ensuring the correct resistance and simplifying installation operations. In this framework, finite element simulations may represent a suitable approach to validate the conformity of the proposed material and design. In this paper, this methodology is applied to a camshaft cover of a four-stroke marine engine, currently made of aluminium alloy. A 30% wt GFs/PA6,6 was identified as the most promising material and the novel plastic cover proved to guarantee the correct resistance while ensuring an important reduction in weight, processing costs, and required energy

    Possible additional value of 18FDG-PET in managing pancreas intraductal papillary mucinous neoplasms: Preliminary results

    Get PDF
    Although some clinical and radiological features may predict malignancy presence in intraductal papillary mucinous pancreas neoplasms, preoperative diagnosis remains difficult. In this study we present 7 patients with Intraductal Papillary Mucinous Neoplasm (IPMN) studied both with 18FDG-PET and magnetic resonance cholangiopancreatography (MRCP). A focal hypermetabolism was documented in 2 patients (the standardized uptake value in the neoplastic foci was 6.7 and 9), while absence of FDG uptake in the neoplasm area was recorded in the remaining 5 cases. Mean follow-up was 27 months (range 21–34). The final judgement was benign IPMN in 5 cases and malignant IPMN in 2. PET scan always correctly predicted the presence or absence of malignancy, while MRCP failed to detect malignancy in 3/7 cases. In conclusion, this preliminary experience suggests that 18FDG-PET may prove useful for malignancy detection in IPMN, improving differential diagnosis with benign intraductal papillary growth by functional data

    Target normal sheath acceleration: theory, comparison with experiments and future perspectives

    Get PDF
    Ions can be effectively accelerated during the interaction of an ultra-intense ultra-short laser pulse irradiating a thin solid target via the so-called target normal sheath acceleration (TNSA) mechanism. One of the pivotal questions at this stage of the research is how to predict the properties of the accelerated ions, both from a fundamental point of view and in the light of foreseen applications. In this context, it is desirable to have a simple but reliable description to be used to extrapolate current results to future regimes, which will be made available in the near future, thanks to developments in laser technology. In this paper, the possible approaches for an analytical description of TNSA are discussed, and a theoretical TNSA model is developed. This model is then used to investigate the maximum ion energy as a function of laser parameters. Detailed comparisons with available experimental data and scaling laws are presented. In particular, the relative role played by both the laser pulse energy and irradiance in determining the ion features is investigated

    State of the art of 18F-FDG PET/CT application in inflammation and infection: a guide for image acquisition and interpretation

    Get PDF
    Aim The diagnosis, severity and extent of a sterile inflammation or a septic infection could be challenging since there is not one single test able to achieve an accurate diagnosis. The clinical use of 18F-fluorodeoxyglucose ([F-18]FDG) positron emission tomography/computed tomography (PET/CT) imaging in the assessment of inflammation and infection is increasing worldwide. The purpose of this paper is to achieve an Italian consensus document on [F-18]FDG PET/CT or PET/MRI in inflammatory and infectious diseases, such as osteomyelitis (OM), prosthetic joint infections (PJI), infective endocarditis (IE), prosthetic valve endocarditis (PVE), cardiac implantable electronic device infections (CIEDI), systemic and cardiac sarcoidosis (SS/CS), diabetic foot (DF), fungal infections (FI), tuberculosis (TBC), fever and inflammation of unknown origin (FUO/IUO), pediatric infections (PI), inflammatory bowel diseases (IBD), spine infections (SI), vascular graft infections (VGI), large vessel vasculitis (LVV), retroperitoneal fibrosis (RF) and COVID-19 infections. Methods In September 2020, the inflammatory and infectious diseases focus group (IIFG) of the Italian Association of Nuclear Medicine (AIMN) proposed to realize a procedural paper about the clinical applications of [F-18]FDG PET/CT or PET/MRI in inflammatory and infectious diseases. The project was carried out thanks to the collaboration of 13 Italian nuclear medicine centers, with a consolidate experience in this field. With the endorsement of AIMN, IIFG contacted each center, and the pediatric diseases focus group (PDFC). IIFG provided for each team involved, a draft with essential information regarding the execution of [F-18]FDG PET/CT or PET/MRI scan (i.e., indications, patient preparation, standard or specific acquisition modalities, interpretation criteria, reporting methods, pitfalls and artifacts), by limiting the literature research to the last 20 years. Moreover, some clinical cases were required from each center, to underline the teaching points. Time for the collection of each report was from October to December 2020. Results Overall, we summarized 291 scientific papers and guidelines published between 1998 and 2021. Papers were divided in several sub-topics and summarized in the following paragraphs: clinical indications, image interpretation criteria, future perspectivess and new trends (for each single disease), while patient preparation, image acquisition, possible pitfalls and reporting modalities were described afterwards. Moreover, a specific section was dedicated to pediatric and PET/MRI indications. A collection of images was described for each indication. Conclusions Currently, [F-18]FDG PET/CT in oncology is globally accepted and standardized in main diagnostic algorithms for neoplasms. In recent years, the ever-closer collaboration among different European associations has tried to overcome the absence of a standardization also in the field of inflammation and infections. The collaboration of several nuclear medicine centers with a long experience in this field, as well as among different AIMN focus groups represents a further attempt in this direction. We hope that this document will be the basis for a "common nuclear physicians' language" throughout all the country

    Age of the Mt. Ortles ice cores, the Tyrolean Iceman and glaciation of the highest summit of South Tyrol since the Northern Hemisphere Climatic Optimum

    Get PDF
    In 2011 four ice cores were extracted from the summit of Alto dell'Ortles (3859 m), the highest glacier of South Tyrol in the Italian Alps. This drilling site is located only 37 km southwest from where the Tyrolean Iceman, similar to 5.3 kyrs old, was discovered emerging from the ablating ice field of Tisenjoch (3210 m, near the Italian-Austrian border) in 1991. The excellent preservation of this mummy suggested that the Tyrolean Iceman was continuously embedded in prehistoric ice and that additional ancient ice was likely preserved elsewhere in South Tyrol. Dating of the ice cores from Alto dell'Ortles based on Pb-210, tritium, beta activity and C-14 determinations, combined with an empirical model (COPRA), provides evidence for a chronologically ordered ice stratigraphy from the modern glacier surface down to the bottom ice layers with an age of similar to 7 kyrs, which confirms the hypothesis. Our results indicate that the drilling site has continuously been glaciated on frozen bedrock since similar to 7 kyrs BP. Absence of older ice on the highest glacier of South Tyrol is consistent with the removal of basal ice from bedrock during the Northern Hemisphere Climatic Optimum (6-9 kyrs BP), the warmest interval in the European Alps during the Holocene. Borehole inclinometric measurements of the current glacier flow combined with surface ground penetration radar (GPR) measurements indicate that, due to the sustained atmospheric warming since the 1980s, an acceleration of the glacier Alto dell'Ortles flow has just recently begun. Given the stratigraphic-chronological continuity of the Mt. Ortles cores over millennia, it can be argued that this behaviour has been unprecedented at this location since the Northern Hemisphere Climatic Optimum
    • …
    corecore