175 research outputs found

    New insulin glargine 300 U/ml compared with glargine 100 U/ml in insulin-naïve people with type 2 diabetes on oral glucose-lowering drugs:a randomized controlled trial (EDITION 3)

    Get PDF
    AIMS: To compare the efficacy and safety of new insulin glargine 300 U/ml (Gla-300) with that of glargine 100 U/ml (Gla-100) in insulin-naïve people with type 2 diabetes using oral glucose-lowering drugs. METHODS: The EDITION 3 study was a multicentre, open-label, parallel-group study. Participants were randomized to Gla-300 or Gla-100 once daily for 6 months, discontinuing sulphonylureas and glinides, with a dose titration aimed at achieving pre-breakfast plasma glucose concentrations of 4.4–5.6 mmol/l (80–100 mg/dl). The primary endpoint was change in glycated haemoglobin (HbA1c) from baseline to month 6. The main secondary endpoint was percentage of participants with ≥1 nocturnal confirmed [≤3.9 mmol/l (≤70 mg/dl)] or severe hypoglycaemia from week 9 to month 6. Other measures of glycaemia and hypoglycaemia, weight change and insulin dose were assessed. RESULTS: Randomized participants (n = 878) had a mean (standard deviation) age of 57.7 (10.1) years, diabetes duration 9.8 (6.4) years, body mass index 33.0 (6.7) kg/m(2) and HbA1c 8.54 (1.06) % [69.8 (11.6) mmol/mol]. HbA1c levels decreased by equivalent amounts with the two treatments; the least squares mean difference in change from baseline was 0.04 [95% confidence interval (CI) −0.09 to 0.17] % or 0.4 (−1.0 to 1.9) mmol/mol. Numerically fewer participants reported ≥1 nocturnal confirmed (≤3.9 mmol/l) or severe hypoglycaemia from week 9 to month 6 [relative risk (RR) 0.89 (95% CI 0.66 to 1.20)] with Gla-300 versus Gla-100; a significantly lower risk of hypoglycaemia with this definition was found over the 6-month treatment period [RR 0.76 (95% CI 0.59 to 0.99)]. No between-treatment differences in adverse events were identified. CONCLUSIONS: Gla-300 is as effective as Gla-100 in reducing HbA1c in insulin-naïve people with type 2 diabetes, with lower hypoglycaemia risk

    New Insulin Glargine 300 Units/mL Versus Glargine 100 Units/mL in People With Type 1 Diabetes: A Randomized, Phase 3a, Open-Label Clinical Trial (EDITION 4)

    Get PDF
    OBJECTIVE Insulin therapy in type 1 diabetes still provides suboptimal outcomes. Insulin glargine 300 units/mL (Gla-300), with a flatter pharmacodynamic profile compared with insulin glargine 100 units/mL (Gla-100), is an approach to this problem. RESEARCH DESIGN AND METHODS People with type 1 diabetes, using a mealtime and basal insulin regimen, were randomized open-label to Gla-300 or Gla-100 and to morning or evening injection, continuing the mealtime analog, and followed for 6 months. RESULTS Participants (n = 549) were a mean age of 47 years and had a mean duration of diabetes of 21 years and BMI of 27.6 kg/m2. The change in HbA1c (primary end point; baseline 8.1%) was equivalent in the two treatment groups (difference, 0.04% [95% CI −0.10 to 0.19]) (0.4 mmol/mol [−1.1 to 2.1]), and Gla-300 was thus noninferior. Similar results with wider 95% CIs were found for morning and evening injection times and for prebreakfast self-measured plasma glucose (SMPG) overall. Results were also similar for Gla-300 when morning and evening injection time was compared, including overlapping 8-point SMPG profiles. Hypoglycemia did not differ, except for the first 8 weeks of the study, when nocturnal confirmed or severe hypoglycemia was lower with Gla-300 (rate ratio 0.69 [95% CI 0.53–0.91]). Hypoglycemia with Gla-300 did not differ by time of injection. The basal insulin dose was somewhat higher at 6 months for Gla-300. The adverse event profile did not differ and was independent of the Gla-300 time of injection. Weight gain was lower with Gla-300. CONCLUSIONS In long-duration type 1 diabetes, Gla-300 provides similar glucose control to Gla-100, with a lower risk of hypoglycemia after transfer from other insulins, independent of time of injection, and less weight gain

    Incretin-Based Therapies for the Treatment of Type 2 Diabetes: Evaluation of the Risks and Benefits

    Get PDF
    Limited evidence suggests that GLP-I may also preserve ventricular function and improve outcomes in human subjects with heart failure or myocardial infarction (11,12). [...] both exenatide and liraglutide reduce blood pressure, body weight, and plasma lipid profiles in subjects with type 2 diabetes (13), raising the hope that longterm treatment with these agents may reduce the incidence of cardiovascular events.\n However, two safety issues have been raised - pancreatitis and medullary carcinoma of the thyroid

    Differences in the Management of Type 1 Diabetes Among Adults Under Excellent Control Compared With Those Under Poor Control in the T1D Exchange Clinic Registry

    Get PDF
    OBJECTIVEOptimizing glycemic control in type 1 diabetes is important to minimize the risk of complications. We used the large T1D Exchange clinic registry database to identify characteristics and diabetes management techniques in adults with type 1 diabetes, differentiating those under excellent glycemic control from those with poorer control.RESEARCH DESIGN AND METHODSThe cross-sectional analysis included 627 participants with HbA1c <6.5% (excellent control) and 1,267 with HbA1c ≥8.5% (fair/poor control) at enrollment who were ≥26 years of age (mean ± SD 45.9 ± 13.2 years), were not using continuous glucose monitoring, and had type 1 diabetes for ≥2 years (22.8 ± 13.0 years).RESULTSCompared with the fair/poor control group, participants in the excellent control group had higher socioeconomic status, were more likely to be older and married, were less likely to be overweight, were more likely to exercise frequently, and had lower total daily insulin dose per kilogram (P < 0.0001 for each). Excellent control was associated with more frequent self-monitoring of blood glucose (SMBG), giving mealtime boluses before a meal rather than at the time of or after a meal, performing SMBG before giving a bolus, and missing an insulin dose less frequently (P < 0.0001 for each). Frequency of severe hypoglycemia was similar between groups, whereas diabetic ketoacidosis was more common in the fair/poor control group.CONCLUSIONSDiabetes self-management related to insulin delivery, glucose monitoring, and lifestyle tends to differ among adults with type 1 diabetes under excellent control compared with those under poorer control. Future studies should focus on modifying diabetes management skills in adult type 1 diabetes patients with suboptimal glycemic control

    Efficacy and Safety of Flexible Versus Fixed Dosing Intervals of Insulin Glargine 300 U/mL in People with Type 2 Diabetes

    Get PDF
    Background: Insulin glargine 300 U/mL (Gla-300) has a more constant and prolonged action profile than insulin glargine 100 U/mL and in clinical studies is associated with similar glycemic control but less hypoglycemia. Whether its effects are altered by variability of injection time was examined in two 3-month substudies. Materials and Methods: Eligible participants completing 6 months of optimized treatment with Gla-300 in EDITION 1 (n = 109) and EDITION 2 (n = 89), having a mean hemoglobin A1c (HbA(1c)) level of 7.3 % (SD 1.0 %), were randomized (1:1) to groups advised to increase variability of between-injection intervals to 24 +/- up to 3 h or to maintain fixed 24-h intervals for 3 months. Changes of HbA(1c) level and other efficacy and safety measures were assessed. Results: In the fixed-dosing group, 64% of participants reported all intervals within the 23-25-h range, compared with 15% of those advised flexible dosing. In the fixed- and flexible-dosing groups, 12% and 41%, respectively, of between-injection intervals were outside the 23-25-h range, and 2% and 16%, respectively, were outside the 21-27-h range. Least squares mean between-group difference in HbA(1c) change from baseline was 0.05 % (95% confidence interval [CI], -0.13 to 0.23); for fasting plasma glucose, 2.7 mg/dL (95% CI, -9.0 to 14.4); and for daily basal insulin dose, 0.00 U/kg (95% CI, -0.02 to 0.03). Frequencies of hypoglycemia and adverse events did not differ between groups. Conclusions: The efficacy and safety of Gla-300 demonstrated in EDITION 1 and EDITION 2 are maintained in substudies when the insulin was injected up to 3 h before or after the usual time of administration.Peer reviewe

    Emerging role of insulin with incretin therapies for management of type 2 diabetes

    Get PDF
    Type 2 diabetes mellitus (T2DM) is a progressive disease warranting intensification of treatment, as beta-cell function declines over time. Current treatment algorithms recommend metformin as the first-line agent, while advocating the addition of either basal-bolus or premixed insulin as the final level of intervention. Incretin therapy, including incretin mimetics or enhancers, are the latest group of drugs available for treatment of T2DM. These agents act through the incretin axis, are currently recommended as add-on agents either as second-or third-line treatment, without concurrent use of insulin. Given the novel role of incretin therapy in terms of reducing postprandial hyperglycemia, and favorable effects on weight with reduced incidence of hypoglycemia, we explore alternative options for incretin therapy in T2DM management. Furthermore, as some evidence alludes to incretins potentially increasing betacell mass and altering disease progression, we propose introducing these agents earlier in the treatment algorithm. In addition, we suggest the concurrent use of incretins with insulin, given the favorable effects especially in relation to weight gain

    Emerging technologies for the management of Type 1 diabetes in pregnancy

    Get PDF
    Purpose of Review: The purpose of the study is to discuss emerging technologies available in the management of type 1 diabetes in pregnancy. Recent Findings: The latest evidence suggests that continuous glucose monitoring (CGM) should be offered to all women on intensive insulin therapy in early pregnancy. Studies have additionally demonstrated the ability of CGM to help gain insight into specific glucose profiles as they relate to glycaemic targets and pregnancy outcomes. Despite new studies comparing insulin pump therapy to multiple daily injections, its effectiveness in improving glucose and pregnancy outcomes remains unclear. Sensor-integrated insulin delivery (also called artificial pancreas or closed-loop insulin delivery) in pregnancy has been demonstrated to improve time in target and performs well despite the changing insulin demands of pregnancy. Summary: Emerging technologies show promise in the management of type 1 diabetes in pregnancy; however, research must continue to keep up as technology advances. Further research is needed to clarify the role technology can play in optimising glucose control before and during pregnancy as well as to understand which women are candidates for sensor-integrated insulin delivery

    Assessing the effectiveness of a 3-month day-and-night home closed-loop control combined with pump suspend feature compared with sensor-augmented pump therapy in youths and adults with suboptimally controlled type 1 diabetes: a randomised parallel study protocol

    Get PDF
    Introduction:\textbf{Introduction:} Despite therapeutic advances, many individuals with type 1 diabetes are unable to achieve tight glycaemic target without increasing the risk of hypoglycaemia. The objective of this study is to determine the effectiveness of a 3-month day-and-night home closed-loop glucose control combined with a pump suspend feature, compared with sensor-augmented insulin pump therapy in youths and adults with suboptimally controlled type 1 diabetes. Methods and analysis:\textbf{Methods and analysis:} The study adopts an open-label, multi-centre, multi-national (UK and USA), randomised, single-period, parallel design and aims for 84 randomised patients. Participants are youths (6-21 years) or adults (>21 years) with type 1 diabetes treated with insulin pump therapy and suboptimal glycaemic control (glycated haemoglobin (HbA1c) ≥7.5% (58 mmol/mol) and ≤10% (86 mmol/mol)). Following a 4-week run-in period, eligible participants will be randomised to a 3-month use of automated closed-loop insulin delivery combined with pump suspend feature or to sensor-augmented insulin pump therapy. Analyses will be conducted on an intention-to-treat basis. The primary outcome is the time spent in the target glucose range from 3.9 to 10.0 mmol/L based on continuous glucose monitoring levels during the 3-month free-living phase. Secondary outcomes include HbA1c at 3 months, mean glucose, time spent below and above target; time with glucose levels 16.7 mmol/L, glucose variability; total, basal and bolus insulin dose and change in body weight. Participants' and their families' perception in terms of lifestyle change, daily diabetes management and fear of hypoglycaemia will be evaluated. Ethics and dissemination:\textbf{Ethics and dissemination:} Ethics/institutional review board approval has been obtained. Before screening, all participants/guardians will be provided with oral and written information about the trial. The study will be disseminated by peer-reviewed publications and conference presentations. Trial registration number:\textbf{Trial registration number:} NCT02523131; Pre-results.JDRF, National Institute for Health Research Cambridge Biomedical Research Centre, Wellcome Strategic Award (100574/Z/12/Z)

    Exenatide once weekly treatment maintained improvements in glycemic control and weight loss over 2 years

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The once-weekly (QW) formulation of the glucagon-like peptide-1 receptor agonist exenatide has been demonstrated to improve A1C, fasting plasma glucose (FPG), body weight, serum lipid profiles, and blood pressure in patients with type 2 diabetes through 52 weeks of treatment. In this report, we describe the 2-year results of the open-label, open-ended extension to the DURATION-1 trial of exenatide QW for type 2 diabetes.</p> <p>Methods</p> <p>A 2-stage protocol was used: patients received either exenatide QW (2 mg) or exenatide twice daily for 30 weeks (5 μg for the first 4 weeks and 10 μg thereafter), followed by 1.5 years of treatment with exenatide QW (2 mg), for a total of 2 years (104 weeks) of exenatide treatment. Of the 295 (intent-to-treat [ITT]) patients who entered the trial, 73% (n = 216) completed 2 years of treatment (completer population). Baseline characteristics (mean ± SE) for these patients were: A1C, 8.2 ± 0.1%; FPG, 168.4 ± 43.0 mg/dL; body weight, 101.1 ± 18.7 kg; and diabetes duration, 7 ± 5 years.</p> <p>Results</p> <p>In the completer population, significant improvements (LS mean ± SE [95% CI]) were maintained after 2 years of treatment in A1C (-1.71 ± 0.08% [-1.86 to -1.55%]), FPG (-40.1 ± 2.9 mg/dL [-45.7 to -34.5 mg/dL]), and body weight (-2.61 ± 0.52 kg [-3.64 to -1.58 kg]) compared with baseline. The percentages of patients who achieved an A1C of <7.0% and ≤6.5% at 2 years were 60% and 39%, respectively. A significant reduction in systolic blood pressure (SBP; -3.0 ± 1.0 mmHg [-4.9 to -1.1 mmHg]) was maintained through 2 years of treatment. Serum lipid profiles were also significantly improved, including triglycerides (geometric LS mean change from baseline, -15 ± 2.7% [-21% to -10%]), total cholesterol (-8.6 ± 2.8 mg/dL [-14.0 to -3.1 mg/dL]), and low-density lipoproteins (-4.5 ± 2.2 mg/dL [-8.9 to -0.01 mg/dL]). Changes in A1C, body weight, FPG, SBP, and lipids in the ITT population were similar to those seen in the completer population. Nausea (predominantly mild in intensity) was the most common adverse event, although the frequency and intensity of nausea decreased over time. No severe hypoglycemia was observed.</p> <p>Conclusions</p> <p>Exenatide QW was well tolerated during the 2-year treatment period. This study demonstrated sustained glucose control and weight loss throughout 2 years of treatment with exenatide QW.</p> <p>Trial Registration</p> <p>ClinicalTrials.gov <a href="http://www.clinicaltrials.gov/ct2/show/NCT00308139">NCT00308139</a></p
    corecore