128 research outputs found

    Highly efficient vortex four-wave mixing in asymmetric semiconductor quantum wells

    Get PDF
    © 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement Orbital angular momentum (OAM) is an important property of vortex light, which provides a valuable tool to manipulate the light-matter interaction in the study of classical and quantum optics. Here we propose a scheme to generate vortex light fields via four-wave mixing (FWM) in asymmetric semiconductor quantum wells. By tailoring the probe-field and control-field detunings, we can effectively manipulate the helical phase and intensity of the FWM field. Particularly, when probe field and control field have identical detuning, we find that both the absorption and phase twist of the generated FWM field are significantly suppressed. Consequently, the highly efficient vortex FWM is realized, where the maximum conversion efficiency reaches around 50%. Our study provides a tool to transfer vortex wavefronts from input to output fields in an efficient way, which may find potential applications in solid-state quantum optics and quantum information processing

    Fiber-optic acoustic pressure sensor based on large-area nanolayer silver diaghragm

    Get PDF
    This is the published version. © 2014 Optical Society of AmericaA fiber-optic acoustic pressure sensor based on a large-area nanolayer silver diaphragm is demonstrated with a high dynamic pressure sensitivity of 160  nm/Pa at 4 kHz frequency. The sensor exhibits a noise limited detectable pressure level of 14.5  μPa/Hz1/2. Its high dynamic pressure sensitivity and simple fabrication process make it an attractive tool for acoustic sensing and photo-acoustic spectroscopy

    Analysis of solids with different matrices by buffer-gas-assisted laser ionization orthogonal time-of-flight mass spectrometry

    Get PDF
    A laser ionization orthogonal time-of-flight mass spectrometer with a low-pressure source and high laser irradiance was used to analyze 27 solid samples with 9 different matrices, including aluminium, soil, copper sulfide, zinc sulfide, iron, nickel, copper, zinc, and tungsten. The influence of laser energy on non-stoichiometric effects, such as matrix effects and elemental fractionation, has been investigated. The results indicate that matrix effects can be alleviated to a great extent at high laser irradiance. Additionally, with the irradiance of 10(10)-10(11) Wcm(-2), most elements presented relatively stable relative sensitivity coefficients (RSC), while W, Pb, and Bi demonstrated unusual characteristics that their RSCs increased along with increasing laser energy.National 863 program ; Natural Science Foundation of China ; Fujian Province Department of Science Technolog

    Semi-quantitative analysis of geological samples using laser plasma time-of-flight mass spectrometry

    Get PDF
    A method has been developed that allows the direct measurement of the elemental composition of geological samples based on a newly developed laser plasma time-of-flight mass spectrometer with a collisional cooling system. This technique has the merits of small sample consumption and rapid elemental analysis. Four geological reference materials were used in the experiment. The system has shown a satisfactory resolving power with few interferences in the spectra. The limits of detection were about 10(-6)-10(-7) g g(-1) for most of the metal elements. The relative sensitivity coefficients (RSCs) of the elements with mass heavier than 30 amu could be used for direct semi-quantitative analysis.National 863 program ; Fujian Province Department of Science Technology ; National Natural Science Foundation of Chin

    Tunable replica symmetry breaking in random laser

    Get PDF
    Replica symmetry breaking (RSB) has been widely recognized as a statistical analysis approach to understand the disorder and nonlinear interactions in complex systems ranging from atoms to the cosmic scale. However, it is challenging to analyze the nonlinear optical characteristics of random laser (RL) in disordered gain medium via RSB due to the lack of a general RSB-based statistical analysis framework. In this work, we report the tunable RSB in polymer fiber RL, where the effects of temperature and different structures on RSB are investigated experimentally and theoretically. It experimentally proves that RSB in RL is not robust, and disorder and temperature are responsible for tunable RSB in RL, which contributes to the improvement of the statistical analysis framework for investigating the optical principles of RL using RSB. And the finding of the tunable RSB allows to investigate the dynamical differences for various RL systems, which broadens the directions for the use of spin-glass theory to explore the physical mechanism of RL

    Efficient and tunable liquid crystal random laser based on plasmonic-enhanced FRET

    Get PDF
    Random lasers (RLs), which possess peculiar advantages (e.g., emission and coherence tunable) over traditional lasers with optical resonators, have witnessed rapid development in the past decades. However, it is still a challenge to tune the lasing peak of an RL over a wide range. Here, a temperature-dependent Förster resonance energy transfer (FRET) RL is demonstrated in pyrromethene 597 (PM597, “donor”) and Nile blue (NB, “acceptor”) doped chiral liquid crystals. By changing the temperature that drives the liquid crystal bandgap shift, our RL device exhibits a lasing output change from 560 nm (yellow) to 700 nm (red). While the intrinsic FRET efficiency between PM597 and NB is relatively low, the red lasing is weak. By introducing gold nanorods (GNRs) into these RL devices and utilizing GNRs’ localized surface plasmon resonance (LSPR) effect, the efficiency of FRET transfer is increased by 68.9%, thereby reducing the threshold of the RL devices. By tuning the longitudinal LSPR to match the emission wavelength of NB, the best 200-fold lasing intensity enhancement is recorded. Our findings open a pathway toward realizing LSPR-enhanced FRET tunable RLs and broaden the range of their possible exploration in photonics research and technologies

    Direct infusion mass spectrometry or liquid chromatography mass spectrometry for human metabonomics? A serum metabonomic study of kidney cancer

    Get PDF
    Serum samples from kidney cancer patients and healthy controls were analyzed by both direct infusion mass spectrometry (DIMS) and liquid chromatography-mass spectrometry (LC-MS) with a high resolution ESI-Q-TOFMS. The classification and biomarker discovery capacities of the two methods were compared, and MS/MS experiments were carried out to identify potential biomarkers. DIMS had comparable classification and prediction capabilities to LC-MS but consumed only similar to 5% of the analysis time. With regard to biomarker discovery, twenty-three variables were found as potential biomarkers by DIMS, and 48 variables were obtained by LC-MS. DIMS is recommended to be a fast diagnostic method for kidney cancer, while LC-MS is necessary when comprehensive screening of biomarkers is required.Medical Center Construction Foundation of Xiamen ; Fujian Province Department of Science Technology ; National Natural Science Foundation of China [20775063

    Comparison of effectiveness of Halo-femoral traction after anterior spinal release in severe idiopathic and congenital scoliosis: a retrospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Halo-femoral traction could gradually improve the coronal and sagittal deformity and restore the trunk balance through the elongation of the spine. The purpose of this retrospective study was to assess the effectiveness of Halo-femoral traction after anterior spinal release in the management of severe idiopathic and congenital scoliosis.</p> <p>Methods</p> <p>Sixty patients with severe and rigid curve treated with anterior spinal release, Halo-femoral traction, and second stage posterior spinal fusion were recruited for this retrospective study. Idiopathic Scoliosis (IS) group was 30 patients (23 females and 7 males) with mean age of 15.5 years. The average coronal Cobb angle was 91.6° and the mean global thoracic kyphosis was 50.6°. The curve type of these patients were 2 with Lenke 1AN, 4 with Lenke 1A+, 1 with Lenke 1BN, 10 with Lenke 1CN, 3 with Lenke 1C+, 3 with Lenke 3CN, 3 with Lenke 3C+, and 4 with Lenke 5C+. Congenital Scoliosis (CS) group included 30 patients (20 females and 10 males) with average age of 15.2 years. The average coronal Cobb angle of the main curve before operation was 95.7° and the average thoracic kyphosis was 70.2°. All patients had a minimum 12-month follow-up radiograph (range 12–72 months, mean 38 months).</p> <p>Results</p> <p>The average traction time was 23 days and the average traction weight was 16 kg. Four patients experienced brachial plexus palsy and complete nerve functional restoration was achieved at two months follow-up. For the IS group, the post-operative mean Cobb angle of major curve averaged 40.1° with correction rate of 57.5%. For the CS group, the post-operative mean Cobb angle was 56.5° with average correction rate of 45.2%. The difference in curve magnitude between the IS and CS patients after posterior correction was statistically significant (t = 4.15, p < 0.001). The correction rate of kyphosis between IS and CS patients was also statistically significant (t = -2.59, p < 0.016).</p> <p>Conclusion</p> <p>Halo-femoral traction was a safe, well-tolerated and effective method for the treatment of severe and rigid scoliosis patients. The posterior correction rate obtained after anterior release and traction was significant superior than that recorded from side bending film in current study.</p

    Atrasentan and renal events in patients with type 2 diabetes and chronic kidney disease (SONAR): a double-blind, randomised, placebo-controlled trial

    Get PDF
    Background: Short-term treatment for people with type 2 diabetes using a low dose of the selective endothelin A receptor antagonist atrasentan reduces albuminuria without causing significant sodium retention. We report the long-term effects of treatment with atrasentan on major renal outcomes. Methods: We did this double-blind, randomised, placebo-controlled trial at 689 sites in 41 countries. We enrolled adults aged 18–85 years with type 2 diabetes, estimated glomerular filtration rate (eGFR)25–75 mL/min per 1·73 m 2 of body surface area, and a urine albumin-to-creatinine ratio (UACR)of 300–5000 mg/g who had received maximum labelled or tolerated renin–angiotensin system inhibition for at least 4 weeks. Participants were given atrasentan 0·75 mg orally daily during an enrichment period before random group assignment. Those with a UACR decrease of at least 30% with no substantial fluid retention during the enrichment period (responders)were included in the double-blind treatment period. Responders were randomly assigned to receive either atrasentan 0·75 mg orally daily or placebo. All patients and investigators were masked to treatment assignment. The primary endpoint was a composite of doubling of serum creatinine (sustained for ≥30 days)or end-stage kidney disease (eGFR <15 mL/min per 1·73 m 2 sustained for ≥90 days, chronic dialysis for ≥90 days, kidney transplantation, or death from kidney failure)in the intention-to-treat population of all responders. Safety was assessed in all patients who received at least one dose of their assigned study treatment. The study is registered with ClinicalTrials.gov, number NCT01858532. Findings: Between May 17, 2013, and July 13, 2017, 11 087 patients were screened; 5117 entered the enrichment period, and 4711 completed the enrichment period. Of these, 2648 patients were responders and were randomly assigned to the atrasentan group (n=1325)or placebo group (n=1323). Median follow-up was 2·2 years (IQR 1·4–2·9). 79 (6·0%)of 1325 patients in the atrasentan group and 105 (7·9%)of 1323 in the placebo group had a primary composite renal endpoint event (hazard ratio [HR]0·65 [95% CI 0·49–0·88]; p=0·0047). Fluid retention and anaemia adverse events, which have been previously attributed to endothelin receptor antagonists, were more frequent in the atrasentan group than in the placebo group. Hospital admission for heart failure occurred in 47 (3·5%)of 1325 patients in the atrasentan group and 34 (2·6%)of 1323 patients in the placebo group (HR 1·33 [95% CI 0·85–2·07]; p=0·208). 58 (4·4%)patients in the atrasentan group and 52 (3·9%)in the placebo group died (HR 1·09 [95% CI 0·75–1·59]; p=0·65). Interpretation: Atrasentan reduced the risk of renal events in patients with diabetes and chronic kidney disease who were selected to optimise efficacy and safety. These data support a potential role for selective endothelin receptor antagonists in protecting renal function in patients with type 2 diabetes at high risk of developing end-stage kidney disease. Funding: AbbVie
    corecore