8 research outputs found

    The accuracy of three-dimensional rapid prototyped surgical template guided anterior segmental osteotomy

    Get PDF
    Surgical guiding templates provided a reliable way to transfer the simulation to the actual operation. However, there was no template designed for anterior segmental osteotomy so far. The study aimed to introduce and evaluate a set of 3D rapid prototyping surgical templates used in anterior segmental osteotomy. From August 2015 to August 2017, 17 patients with bimaxillary protrusions were recruited and occlusal-based multi-sectional templates were applied in the surgeries. The cephalometric analysis and 3D superimposition were performed to evaluate the differences between the simulations and actual post-operative outcomes. The patients were followed-up for 12 months to evaluate the incidence rate of complications and relapse. Bimaxillary protrusion was corrected in all patients with no complication. In radiographic evaluations, there was no statistically significant difference between the actual operations and the computer-aided 3D simulations (p >0.05, the mean linear and angular differences were less than 1.32mm and 1.72° consequently, and 3D superimposition difference was less than 1.4mm). The Pearson intraclass correlation coefficient reliabilities were high (0.897), and the correlations were highly significant (P< 0.001). The 3D printed surgical template designed in this study can safely and accurately transfer the computer-aided 3D simulation into real practice

    Evaluation of the Properties of 3D-Printed Ti Alloy Plates: <i>In Vivo</i> and <i>In Vitro</i> Comparative Experimental Study

    No full text
    Titanium (Ti)-based implants play a significant role in rigid internal fixation in maxillofacial surgery. No study has reported that three-dimensional-printed Ti alloy plates (3D-Ti plates) have comprehensively excellent properties similar to standard plates (Matrix-MANDIBLE, SYNTHES, Switzerland) (Synthes-Ti plates). In this work, we manufactured 3D-Ti plates by selective laser melting with Ti6Al4V powder. The surface morphology, mechanical properties, and bone–plate contact rate of the 3D-Ti plates and the Synthes-Ti plates were characterized and compared via electron microscopy, atomic force microscopy, Vickers hardness test, three-point bending test, and software calculation. Human bone marrow stromal cells (HBMSCs) were cultured on the plates to test their biocompatibility. Importantly, the 3D-Ti plates were placed into a mandibular fracture model to assess the effect of medical application for 4 and 24 weeks. The 3D-Ti plates were demonstrated to have similar biocompatibility and stability for rigid internal fixation with the Synthes-Ti plates, lower roughness (106.44 ± 78.35 nm), better mechanical strength (370.78 ± 1.25 HV10), and a higher bone–plate contact rate (96.9%). These promising results indicate the feasibility of using 3D-Ti plates for irregular shapes and complex anatomical structures in a clinical context

    Global Incidence and Risk Factors Associated With Postoperative Urinary Retention Following Elective Inguinal Hernia Repair

    No full text
    Importance Postoperative urinary retention (POUR) is a well-recognized complication of inguinal hernia repair (IHR). A variable incidence of POUR has previously been reported in this context, and contradictory evidence surrounds potential risk factors.Objective To ascertain the incidence of, explore risk factors for, and determine the health service outcomes of POUR following elective IHR.Design, Setting, and Participants The Retention of Urine After Inguinal Hernia Elective Repair (RETAINER I) study, an international, prospective cohort study, recruited participants between March 1 and October 31, 2021. This study was conducted across 209 centers in 32 countries in a consecutive sample of adult patients undergoing elective IHR.Exposure Open or minimally invasive IHR by any surgical technique, under local, neuraxial regional, or general anesthesia.Main Outcomes and Measures The primary outcome was the incidence of POUR following elective IHR. Secondary outcomes were perioperative risk factors, management, clinical consequences, and health service outcomes of POUR. A preoperative International Prostate Symptom Score was measured in male patients.Results In total, 4151 patients (3882 male and 269 female; median [IQR] age, 56 [43-68] years) were studied. Inguinal hernia repair was commenced via an open surgical approach in 82.2% of patients (n = 3414) and minimally invasive surgery in 17.8% (n = 737). The primary form of anesthesia was general in 40.9% of patients (n = 1696), neuraxial regional in 45.8% (n = 1902), and local in 10.7% (n = 446). Postoperative urinary retention occurred in 5.8% of male patients (n = 224), 2.97% of female patients (n = 8), and 9.5% (119 of 1252) of male patients aged 65 years or older. Risk factors for POUR after adjusted analyses included increasing age, anticholinergic medication, history of urinary retention, constipation, out-of-hours surgery, involvement of urinary bladder within the hernia, temporary intraoperative urethral catheterization, and increasing operative duration. Postoperative urinary retention was the primary reason for 27.8% of unplanned day-case surgery admissions (n = 74) and 51.8% of 30-day readmissions (n = 72).Conclusions The findings of this cohort study suggest that 1 in 17 male patients, 1 in 11 male patients aged 65 years or older, and 1 in 34 female patients may develop POUR following IHR. These findings could inform preoperative patient counseling. In addition, awareness of modifiable risk factors may help to identify patients at increased risk of POUR who may benefit from perioperative risk mitigation strategies
    corecore