27 research outputs found

    Invasive Plants and Enemy Release: Evolution of Trait Means and Trait Correlations in Ulex europaeus

    Get PDF
    Several hypotheses that attempt to explain invasive processes are based on the fact that plants have been introduced without their natural enemies. Among them, the EICA (Evolution of Increased Competitive Ability) hypothesis is the most influential. It states that, due to enemy release, exotic plants evolve a shift in resource allocation from defence to reproduction or growth. In the native range of the invasive species Ulex europaeus, traits involved in reproduction and growth have been shown to be highly variable and genetically correlated. Thus, in order to explore the joint evolution of life history traits and susceptibility to seed predation in this species, we investigated changes in both trait means and trait correlations. To do so, we compared plants from native and invaded regions grown in a common garden. According to the expectations of the EICA hypothesis, we observed an increase in seedling height. However, there was little change in other trait means. By contrast, correlations exhibited a clear pattern: the correlations between life history traits and infestation rate by seed predators were always weaker in the invaded range than in the native range. In U. europaeus, the role of enemy release in shaping life history traits thus appeared to imply trait correlations rather than trait means. In the invaded regions studied, the correlations involving infestation rates and key life history traits such as flowering phenology, growth and pod density were reduced, enabling more independent evolution of these key traits and potentially facilitating local adaptation to a wide range of environments. These results led us to hypothesise that a relaxation of genetic correlations may be implied in the expansion of invasive species

    Adrenal Mass Characterization in the Era of Quantitative Imaging: State of the Art

    No full text
    Detection and characterization of adrenal lesions have evolved during the past two decades. Although the role of imaging in adrenal lesions associated with hormonal secretion is usually straightforward, characterization of non-functioning adrenal lesions may be challenging to confidently identify those that need to be resected. Although many adrenal lesions can be readily diagnosed when they display typical imaging features, the diagnosis may be challenging for atypical lesions. Computed tomography (CT) remains the cornerstone of adrenal imaging, but other morphological or functional modalities can be used in combination to reach a diagnosis and avoid useless biopsy or surgery. Early- and delayed-phase contrast-enhanced CT images are essential for diagnosing lipid-poor adenoma. Ongoing studies are evaluating the capabilities of dual-energy CT to provide valid virtual non-contrast attenuation and iodine density measurements from contrast-enhanced examinations. Adrenal lesions with attenuation values between 10 and 30 Hounsfield units (HU) on unenhanced CT can be characterized by MRI when iodinated contrast material injection cannot be performed. 18F-FDG PET/CT helps differentiate between atypical benign and malignant adrenal lesions, with the adrenal-to-liver maximum standardized uptake value ratio being the most discriminative variable. Recent studies evaluating the capabilities of radiomics and artificial intelligence have shown encouraging results

    Artificial intelligence in diagnostic and interventional radiology: Where are we now?

    No full text
    International audienceThe emergence of massively parallel yet affordable computing devices has been a game changer for research in the field of artificial intelligence (AI). In addition, dramatic investment from the web giants has fostered the development of a high-quality software stack. Going forward, the combination of faster computers with dedicated software libraries and the widespread availability of data has opened the door to more flexibility in the design of AI models. Radiomics is a process used to discover new imaging biomarkers that has multiple applications in radiology and can be used in conjunction with AI. AI can be used throughout the various processes of diagnostic imaging, including data acquisition, reconstruction, analysis and reporting. Today, the concept of "AI-augmented" radiologists is preferred to the theory of the replacement of radiologists by AI in many indications. Current evidence bolsters the assumption that AI-assisted radiologists work better and faster. Interventional radiology becomes a data-rich specialty where the entire procedure is fully recorded in a standardized DICOM format and accessible via standard picture archiving and communication systems. No other interventional specialty can bolster such readiness. In this setting, interventional radiology could lead the development of AI-powered applications in the broader interventional community. This article provides an update on the current status of radiomics and AI research, analyzes upcoming challenges and also discusses the main applications in AI in interventional radiology to help radiologists better understand and criticize articles reporting AI in medical imaging

    Preoperative Arterial Embolization of Musculoskeletal Tumors: A Tertiary Center Experience

    No full text
    The purpose of this study was to report the effectiveness of preoperative transcatheter arterial embolization (TAE) of musculoskeletal tumors in terms of blood loss and functional outcomes. Patients who underwent preoperative TAE of hypervascular musculoskeletal tumors between January 2018 and December 2021 were retrospectively included. The patients’ characteristics, TAE procedure details, degree of post-TAE devascularization, surgical outcomes in terms of red blood cell transfusion and functional results were collected. The degree of devascularization was compared between patients who had peri-operative transfusion and those who did not. Thirty-one patients were included. The 31 TAE procedures led to complete (58%) or near-complete (42%) tumor devascularization. Twenty-two patients (71%) had no blood transfusion during surgery. Nine patients (29%) had a blood transfusion, with a median number of red blood cell packs of three (q1, 2; q3, 4; range: 1–4). Eight patients (27%) had complete improvement of the initial musculoskeletal symptoms at the end of the follow-up, 15 (50%) had partially satisfying improvement, 4 (13%) had partially unsatisfying improvement and 3 (10%) had no improvement. Our study suggests that preoperative TAE of hypervascular musculoskeletal tumors allowed for bloodless surgery in 71% of patients and minimal transfusion needs for the remaining 29%

    Impact of Sarcopenia on Patients with Localized Pancreatic Ductal Adenocarcinoma Receiving FOLFIRINOX or Gemcitabine as Adjuvant Chemotherapy

    No full text
    Background: Despite its toxicity, modified FOLFIRINOX is the main chemotherapy for localized, operable pancreatic adenocarcinomas. Sarcopenia is known as a factor in lower overall survival (OS). The purpose of this study was to assess the impact of sarcopenia on OS in patients with localized pancreatic ductal adenocarcinoma (PDAC) who received modified FOLFIRINOX or gemcitabine as adjuvant chemotherapy. Methods: Patients with operated PDAC who received gemcitabine-based (GEM group) or oxaliplatin-based (OXA group) adjuvant chemotherapy between 2008 and 2021 were retrospectively included. Sarcopenia was estimated on a baseline computed tomography (CT) examination using the skeletal muscular index (SMI). The primary evaluation criterion was OS. Secondary evaluation criteria were disease-free survival (DFS) and toxicity. Results: Seventy patients treated with gemcitabine-based (n = 49) and oxaliplatin-based (n = 21) chemotherapy were included, with a total of fifteen sarcopenic patients (eight in the GEM group and seven in the OXA group). The median OS was shorter in sarcopenic patients (25 months) compared to non-sarcopenic patients (158 months) (p = 0.01). A longer OS was observed in GEM non-sarcopenic patients (158 months) compared to OXA sarcopenic patients (14.4 months) (p < 0.01). The median OS was 157.7 months in the GEM group vs. 34.1 months in the OXA group (p = 0.13). No differences in median DFS were found between the GEM group and OXA group. More toxicity events were observed in the OXA group (50%) than in the GEM group (10%), including vomiting (p = 0.02), mucositis (p = 0.01) and neuropathy (p = 0.01). Conclusion: Sarcopenia is associated with a worse prognosis in patients with localized operated PDAC whatever the delivered adjuvant chemotherapy

    Assessment of hepatic arterial hemodynamics with 4D flow MRI : in vitro analysis of motion and spatial resolution related error and in vivo feasibility study in 20 volunteers

    No full text
    Objectives To assess the ability of four-dimensional (4D) flow MRI to measure hepatic arterial hemodynamics by determining the effects of spatial resolution and respiratory motion suppression in vitro and its applicability in vivo with comparison to two-dimensional (2D) phase-contrast MRI. Methods A dynamic hepatic artery phantom and 20 consecutive volunteers were scanned. The accuracies of Cartesian 4D flow sequences with k-space reordering and navigator gating at four spatial resolutions (0.5- to 1-mm isotropic) and navigator acceptance windows (+/- 8 to +/- 2 mm) and one 2D phase-contrast sequence (0.5-mm in -plane) were assessed in vitro at 3 T. Two sequences centered on gastroduodenal and hepatic artery branches were assessed in vivo for intra - and interobserver agreement and compared to 2D phase-contrast. Results In vitro, higher spatial resolution led to a greater decrease in error than narrower navigator window (30.5 to -4.67% vs -6.64 to -4.67% for flow). In vivo, hepatic and gastroduodenal arteries were more often visualized with the higher resolution sequence (90 vs 71%). Despite similar interobserver agreement (kappa = 0.660 and 0.704), the higher resolution sequence had lower variability for area (CV = 20.04 vs 30.67%), flow (CV = 34.92 vs 51.99%), and average velocity (CV = 26.47 vs 44.76%). 4D flow had lower differences between inflow and outflow at the hepatic artery bifurcation (11.03 +/- 5.05% and 15.69 +/- 6.14%) than 2D phase-contrast (28.77 +/- 21.01%). Conclusion High-resolution 4D flow can assess hepatic artery anatomy and hemodynamics with improved accuracy, greater vessel visibility, better interobserver reliability, and internal consistency
    corecore