33,720 research outputs found

    Oscillating chiral currents in nanotubes: a route to nanoscale magnetic test tubes

    Get PDF
    With a view to optimising the design of carbon-nanotube (CNT) windmills and to maximising the internal magnetic field generated by chiral currents, we present analytical results for the group velocity components of an electron flux through chiral carbon nanotubes. Chiral currents are shown to exhibit a rich behaviour and can even change sign and oscillate as the energy of the electrons is increased. We find that the transverse velocity and associated angular momentum of electrons is a maximum for non-metallic CNTs with a chiral angle of 18o^o. Such CNTs are therefore the optimal choice for CNT windmills and also generate the largest internal magnetic field for a given longitudinal current. For a longitudinal current of order 10−410^{-4} amps, this field can be of order 10−110^{-1}Teslas, which is sufficient to produce interesting spintronic effects and a significant contribution to the self inductance.Comment: 4 pages, 1 figur

    High temperature static strain gage alloy development program

    Get PDF
    The literature, applicable theory and finally an experimental program were used to identify new candidate alloy systems for use as the electrical resistance elements in static strain gages up to 1250K. The program goals were 50 hours of use in the environment of a test stand gas turbine engine with measurement accuracies equal to or better than 10 percent of full scale for strains up to + or - 2000 microstrain. As part of this effort, a computerized electrical resistance measurement system was constructed for use at temperatures between 300K and 1250K and heating and cooling rates of 250K/min and 10K/min. The two best alloys were an iron-chromium-aluminum alloy and a palladium base alloy. Although significant progress was made, it was concluded that a considerable additional effort would be needed to fully optimize and evaluate these candidate systems

    A holistic multimodal approach to the non-invasive analysis of watercolour paintings

    Get PDF
    A holistic approach using non-invasive multimodal imaging and spectroscopic techniques to study the materials (pigments, drawing materials and paper) and painting techniques of watercolour paintings is presented. The non-invasive imaging and spectroscopic techniques include VIS-NIR reflectance spectroscopy and multispectral imaging, micro-Raman spectroscopy, X-ray fluorescence spectroscopy (XRF) and optical coherence tomography (OCT). The three spectroscopic techniques complement each other in pigment identification. Multispectral imaging (near infrared bands), OCT and micro-Raman complement each other in the visualisation and identification of the drawing material. OCT probes the microstructure and light scattering properties of the substrate while XRF detects the elemental composition that indicates the sizing methods and the filler content . The multiple techniques were applied in a study of forty six 19th century Chinese export watercolours from the Victoria & Albert Museum (V&A) and the Royal Horticultural Society (RHS) to examine to what extent the non-invasive analysis techniques employed complement each other and how much useful information about the paintings can be extracted to address art conservation and history questions

    High temperature static strain gage development contract, tasks 1 and 2

    Get PDF
    Results are presented for the first two tasks to develop resistive strain gage systems for use up to 1250 K on blades and vanes in gas turbine engines under tests. The objective of these two tasks was to further improve and evaluate two static strain gage alloys identified as candidates in a previous program. Improved compositions were not found for either alloy. Further efforts on the Fe-11.9Al-10.6Cr weigth percent alloy were discontinued because of time dependent drift problems at 1250 K in air. When produced as a 6.5 micrometer thick sputtered film, the Pd-13Cr weight percent alloys is not sufficiently stable for this use in air at 1250 K and a protective overcoat system will need to be developed

    ‘VIOLET’: a fluorescence-based simulation exercise for training healthcare workers in the use of personal protective equipment

    Get PDF
    Background Healthcare workers caring for patients with high-consequence infectious diseases (HCIDs) require protection from pathogen exposure, for example by wearing personal protective equipment (PPE). Protection is acquired through the inherent safety of the PPE components, but also their safe and correct use, supported by adequate training and user familiarity. However, the evidence base for HCID PPE ensembles and any associated training is lacking, with subsequent variation between healthcare providers. Aim To develop an evidence-based assessment and training tool for evaluating PPE ensembles and doffing protocols, in the assessment of patients with suspected HCIDs. Methods VIOLET (Visualising Infection with Optimised Light for Education and Training) comprises a healthcare mannequin adapted to deliver simulated bodily fluids containing UV-fluorescent tracers. On demand and remotely operated, the mannequin projectile vomits (blue), coughs (red), has diarrhoea (yellow) and is covered in sweat (orange). Wearing PPE, healthcare staff participate in an HCID risk assessment and examination of the ‘patient’, thereby becoming exposed to these bodily fluids. Contamination of PPE is visualized and body-mapped under UV light before and after removal. Observational findings and participant feedback, around its use as a training exercise, is also recorded. Findings Significant contamination from different exposure events was seen, enabling evaluation of PPE and doffing procedures used. Observational data and participant feedback demonstrated its strengths and success as a training technique. Conclusion Simulation exercises using VIOLET provide evidence-based assessment of PPE ensembles, and are a valuable resource for training of healthcare staff in wearing and safe doffing of PPE

    Use of ultraviolet-fluorescence-based simulation in evaluation of personal protective equipment worn for first assessment and care of a patient with suspected high-consequence infectious disease

    Get PDF
    Background: Variations currently exist across the UK in the choice of personal protective equipment (PPE) used by healthcare workers when caring for patients with suspected high-consequence infectious diseases (HCIDs). Aim: To test the protection afforded to healthcare workers by current PPE ensembles during assessment of a suspected HCID case, and to provide an evidence base to justify proposal of a unified PPE ensemble for healthcare workers across the UK. Methods: One ‘basic level’ (enhanced precautions) PPE ensemble and five ‘suspected case’ PPE ensembles were evaluated in volunteer trials using ‘Violet’; an ultraviolet-fluorescence-based simulation exercise to visualize exposure/contamination events. Contamination was photographed and mapped. Findings: There were 147 post-simulation and 31 post-doffing contamination events, from a maximum of 980, when evaluating the basic level of PPE. Therefore, this PPE ensemble did not afford adequate protection, primarily due to direct contamination of exposed areas of the skin. For the five suspected case ensembles, 1584 post-simulation contamination events were recorded, from a maximum of 5110. Twelve post-doffing contamination events were also observed (face, two events; neck, one event; forearm, one event; lower legs, eight events). Conclusion: All suspected case PPE ensembles either had post-doffing contamination events or other significant disadvantages to their use. This identified the need to design a unified PPE ensemble and doffing procedure, incorporating the most protective PPE considered for each body area. This work has been presented to, and reviewed by, key stakeholders to decide on a proposed unified ensemble, subject to further evaluation
    • …
    corecore