5 research outputs found

    10-year stroke prevention after successful carotid endarterectomy for asymptomatic stenosis (ACST-1); a multicentre randomised trial

    Get PDF
    BACKGROUND: If carotid artery narrowing remains asymptomatic (ie, has caused no recent stroke or other neurological symptoms), successful carotid endarterectomy (CEA) reduces stroke incidence for some years. We assessed the long-term effects of successful CEA. METHODS: Between 1993 and 2003, 3120 asymptomatic patients from 126 centres in 30 countries were allocated equally, by blinded minimised randomisation, to immediate CEA (median delay 1 month, IQR 0·3-2·5) or to indefinite deferral of any carotid procedure, and were followed up until death or for a median among survivors of 9 years (IQR 6-11). The primary outcomes were perioperative mortality and morbidity (death or stroke within 30 days) and non-perioperative stroke. Kaplan-Meier percentages and logrank p values are from intention-to-treat analyses. This study is registered, number ISRCTN26156392. FINDINGS: 1560 patients were allocated immediate CEA versus 1560 allocated deferral of any carotid procedure. The proportions operated on while still asymptomatic were 89·7% versus 4·8% at 1 year (and 92·1%vs 16·5% at 5 years). Perioperative risk of stroke or death within 30 days was 3·0% (95% CI 2·4-3·9; 26 non-disabling strokes plus 34 disabling or fatal perioperative events in 1979 CEAs). Excluding perioperative events and non-stroke mortality, stroke risks (immediate vs deferred CEA) were 4·1% versus 10·0% at 5 years (gain 5·9%, 95% CI 4·0-7·8) and 10·8% versus 16·9% at 10 years (gain 6·1%, 2·7-9·4); ratio of stroke incidence rates 0·54, 95% CI 0·43-0·68, p<0·0001. 62 versus 104 had a disabling or fatal stroke, and 37 versus 84 others had a non-disabling stroke. Combining perioperative events and strokes, net risks were 6·9% versus 10·9% at 5 years (gain 4·1%, 2·0-6·2) and 13·4% versus 17·9% at 10 years (gain 4·6%, 1·2-7·9). Medication was similar in both groups; throughout the study, most were on antithrombotic and antihypertensive therapy. Net benefits were significant both for those on lipid-lowering therapy and for those not, and both for men and for women up to 75 years of age at entry (although not for older patients). INTERPRETATION: Successful CEA for asymptomatic patients younger than 75 years of age reduces 10-year stroke risks. Half this reduction is in disabling or fatal strokes. Net benefit in future patients will depend on their risks from unoperated carotid lesions (which will be reduced by medication), on future surgical risks (which might differ from those in trials), and on whether life expectancy exceeds 10 years. FUNDING: UK Medical Research Council, BUPA Foundation, Stroke Association

    Characterization of the LIGO detectors during their sixth science run

    No full text
    In 2009-2010, the Laser Interferometer Gravitational-Wave Observatory (LIGO) operated together with international partners Virgo and GEO600 as a network to search for gravitational waves (GWs) of astrophysical origin. The sensitivity of these detectors was limited by a combination of noise sources inherent to the instrumental design and its environment, often localized in time or frequency, that couple into the GW readout. Here we review the performance of the LIGO instruments during this epoch, the work done to characterize the detectors and their data, and the effect that transient and continuous noise artefacts have on the sensitivity of LIGO to a variety of astrophysical sources

    Characterization of a subset of large amplitude noise events in VIRGO science run 1 (VSR1)

    No full text

    Very low latency search for low mass compact binary coalescences in the LIGO S6 and Virgo VSR2 data

    No full text
    International audienceA very low latency search pipeline has been developed for the LIGO S6 and Virgo VSR2 science runs, targeting signals from coalescing compact binary systems with total mass from 2 to 35 solar masses. The goal of this search is to provide both single-detector triggers and multi-detector coincident triggers with a latency of a few minutes, the former for online detector monitoring and the latter to allow searching for electromagnetic counterparts to possible gravitational wave candidates. The features and current performance of this low latency search pipeline are presented

    Characterization of the LIGO detectors during their sixth science run

    No full text
    In 2009–2010, the Laser Interferometer Gravitational-Wave Observatory (LIGO) operated together with international partners Virgo and GEO600 as a network to search for gravitational waves (GWs) of astrophysical origin. The sensitivity of these detectors was limited by a combination of noise sources inherent to the instrumental design and its environment, often localized in time or frequency, that couple into the GW readout. Here we review the performance of the LIGO instruments during this epoch, the work done to characterize the detectors and their data, and the effect that transient and continuous noise artefacts have on the sensitivity of LIGO to a variety of astrophysical sources
    corecore