112 research outputs found

    Zero-Shot Learning - The Good, the Bad and the Ugly

    Get PDF

    Macrofungal diversity of Bolu Abant Nature Park (Turkey)

    Get PDF
    This study was based on materials of macrofungi collected from Bolu Abant Nature Park between 2008 and 2009. As a result of field and laboratory studies, 103 taxa belonging to 34 families were identified. Five (5) taxa belong to Ascomycota and 98 to Basidiomycota

    Gaze Embeddings for Zero-Shot Image Classification

    Get PDF

    Learning Decision Trees Recurrently Through Communication

    Get PDF

    Generalized Many-Way Few-Shot Video Classification

    Get PDF
    Few-shot learning methods operate in low data regimes. The aim is to learn with few training examples per class. Although significant progress has been made in few-shot image classification, few-shot video recognition is relatively unexplored and methods based on 2D CNNs are unable to learn temporal information. In this work we thus develop a simple 3D CNN baseline, surpassing existing methods by a large margin. To circumvent the need of labeled examples, we propose to leverage weakly-labeled videos from a large dataset using tag retrieval followed by selecting the best clips with visual similarities, yielding further improvement. Our results saturate current 5-way benchmarks for few-shot video classification and therefore we propose a new challenging benchmark involving more classes and a mixture of classes with varying supervision

    {VGSE}: {V}isually-Grounded Semantic Embeddings for Zero-Shot Learning

    Get PDF

    Conductometric Biosensor Based on Urease, Adsorbed on Silicalite for Determination of Urea in Serum Samples

    Get PDF
    The method of enzyme adsorption on nano- and microsized zeolites, developed by us, is described. It is notable by such advantages as simple and fast performance, the absence of toxic compounds, high reproducibility and repeatability. The biosensor based on the method developed was applied for urea measurement in samples of blood serum. It was shown that the biosensor could surely distinguish healthy people from people with renal dysfunction. Good results reproducibility was proved at urea determination in real samples of blood serum (RSD = 10%). For these reasons, the biosensors based on enzyme adsorption are more suitable for standardization and production than those based on conventional methods of immobilization. When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/3547

    Elaboration of new method of enzyme adsorption on silicalite and nano beta zeolite for amperometric biosensor creation

    No full text
    Aim. Optimization of a new method of enzyme immobilization for amperometric biosensor creation. Methods. The amperometric biosensor with glucose oxidase immobilized on zeolites as bioselective elements and platinum disk electrode as transducers of biochemical signal into the electric one was used in the work. Results. The biosensors based on glucose oxidase adsorbed on zeolites were characterized by a higher sensitivity to glucose and a better inter-reproducibility. The best analytical characteristics were obtained for the biosensors based on nano beta zeolite. It has been found that an increase in the amount of zeolite on the surface of amperometric transducer may change such biosensor parameters as sensitivity to the substrate and duration of the analysis. Conclusions. The proposed method of enzyme immobilization by adsorption on zeolites is shown to be quite promising in the development of amperometric biosensors and therefore should be further investigated.Мета. Оптимізація нового методу іммобілізації ферментів для розробки амперометричних біосенсорів. Методи. Використано іммобілізовану глюкозооксидазу на цеоліті як біоселективний елемент біосенсора та платиновий дисковий електрод – як амперометричний перетворювач біохімічного сигналу в електричний. Результати. Біосенсор на основі глюкозооксидази, адсорбованої на цеолітах, вирізняється високою чутливістю до глюкози та покращеною інтер-відновлюваністю виготовлення біосенсорів. Найкращі аналітичні характеристики притаманні біосенсору на основі нано-бета цеоліту. Встановлено, що при зміні кількості цеолітів на поверхні амперметричного перетворювача можна варіювати параметри біосенсора, такі як чутливість до субстрату та час аналізу. Висновки. Показано, що запропонований метод іммобілізації, а саме – адсорбція ферментів на цеолітах є дуже перспективним при розробці амперометричних біосенсорів.Цель. Оптимизация нового метода иммобилизации ферментов для разработки амперометрических биосенсоров. Методы. Использовали иммобилизованную глюкозооксидазу на цеолитах как биоселективный элемент биосенсора и платиновый дисковый электрод – как амперометрический преобразователь биохимического сигнала в электрический. Результаты. Биосенсор на основе глюкозооксидазы, адсорбированной на цеолитах, отличается высокой чувствительностью к глюкозе и улучшенной интер-воспроизводимостью приготовления биосенсоров. Наилучшими аналитическими характеристиками обладает биосенсор на основе нано-бета цеолита. Установлено, что при изменении количества цеолитов на поверхности амперометрического преобразователя можно менять параметры биосенсора, такие как чувствительность к субстрату и время анализа. Выводы. Показано, что предложенный метод иммобилизации, а именно – адсорбция ферментов на цеолитах является перспективным при разработке амперометрических биосенсоров

    Application of silicalite for improvement of enzyme adsorption on the stainless steel electrodes

    No full text
    Aim. Improvement of analytical characteristics of an enzyme biosensor based on new inexpensive perspective stainless steel electrodes using silicalite nanoparticles. Methods. Conductometric enzyme biosensor was used. Results. Three methods of glucose oxidase (GOx) immobilization were studied and compared: GOx adsorption on silicalite modified electrodes (GOx-SME); cross-linking by glutaraldehyde without silicalite (GOx-GA); GOx adsorption on SME along with cross-linking by glutaraldehyde (GOx-SME-GA). The GOx-SME-GA biosensors based on stainless steel electrodes were characterized by 12–25-fold higher sensitivity comparing with other biosensors. The developed GOx-SME-GA biosensors were characterized by good reproducibility of glucose biosensors construction (relative standard deviation (RSD) – 18 %), improved signal reproducibility (RSD of glucose determination was 7 %) and good storage stability (29 % loss of activity after 18 days). Conclusions. The method of enzyme immobilization using silicalite together with GA cross-linking sufficiently enhances the enzyme adsorption on the stainless steel electrodes and improves the analytical parameters of biosensors. This method is found to be promising for further creation of other enzyme biosensors.Мета. Покращення аналітичних характеристик ферментних біосенсорів на основі нових недорогих перспективних електродів з нержавіючої сталі за допомогою наночастинок силікаліту. Методи. Використано кондуктометричний біосенсор з іммобілізованою глюкозооксидазою як біоселективним елементом та сталеві електроди як перетворювачі. Результати. Застосовано і порівняно три методи іммобілізації глюкозооксидази (ГО) на поверхні датчиків: адсорбція ГО на модифікованій частинками силікаліту поверхні електрода; поперечне зшивання ГО з глутаровим альдегідом (ГА) без використання силікаліту; сорбція ГО на модифікованому силікалітом електроді у комбінації з поперечним зшиванням з ГА. Біосенсори з ферментами, іммобілізованими на поверхні сталевого електроду за рахунок сорбції на шарі силікаліту у комбінації з поперечним зшиванням з ГА, мають в 12–25 разів вищу чутливість порівняно з іншими біосенсорами. Ця ж група біосенсорів характеризується високою відтворюваністю сигналів між різними партіями (відносне стандартне відхилення (ВСВ) становить 18 %), а також відтворюваністю в одній партії з ВСВ 7 %. Таким біосенсорам притаманна висока стабільність при зберіганні (втрата лише 29 % від первинного сигналу після 18 днів зберігання). Висновки. Показано, що використання частинок силікаліту поряд з методом поперечного зшивання з ГА значно підвищує сорбцію ферментів на поверхні датчиків з нержавіючої сталі під час іммобілізації, а також покращує аналітичні параметри біосенсорів. Цей метод іммобілізації ферментів може бути застосований для подальшого удосконалення роботи біосенсорів.Цель. Улучшение аналитических характеристик ферментных биосенсоров на основе новых недорогих перспективных электродов с помощью наночастиц силикалита. Методы. Использовали кондуктометрический биосенсор с иммобилизованной глюкозооксидазой в качестве биоселективного элемента и стальные электроды как преобразователь. Результаты. Сопоставлены между собой три метода иммобилизации глюкозооксидазы (ГО) на поверхности преобразователей: адсорбция ГО на поверхности модифицированных силикалитом электродов; поперечная сшивка ГО с глутаровым альдегидом (ГА) без использования силикалита; адсорбция ГО на модифицированном силикалитом преобразователе в комбинации с поперечной сшивкой с ГА. Биосенсоры, созданные вследствие комбинации сорбции ГО на слое силикалита на поверхности стального электрода и сшивки с ГА, имеют чувствительность в 12–25 раз выше, нежели другие биосенсоры. Биосенсоры этой же группы отличаются высокой воспроизводимостью сигналов между разными партиями (относительное стандартное отклонение (ОСО) составляет 18 %), и воспроизводимостью внутри одной партии с ОСО 7 %. Такие биосенсоры обладают высокой стабильностью при хранении (потеря чувствительности в первые 18 дней хранения достигает лишь 29 %). Выводы. Показано, что использование частиц силикалита одновременно с методом поперечной сшивки с ГА в значительной степени повышает сорбцию ферментов на поверхности преобразователей из нержавеющей стали во время иммобилизации, а также улучшает аналитические парметры бисоенсоров. Такой метод иммобилизации ферментов может быть применен для дальнейшего усовершенствования работы биосенсоров
    corecore