673 research outputs found
Influence of normal and radial contributions of local current density on local electrochemical impedance spectroscopy.
A new tri-electrode probe is presented and applied to local electrochemical impedance spectroscopy (LEIS) measurements. As opposed to two-probe systems, the three-probe one allows measurement not only of normal, but also of radial contributions of local current densities to the local impedance values. The results concerning the cases of the blocking electrode and the electrode with faradaic reaction are discussed from the theoretical point of view for a disk electrode. Numerical simulations and experimental results are compared for the case of the ferri/ferrocyanide electrode reaction at the Pt working electrode disk. At the centre of the disk, the impedance taking into account both normal and radial contributions was in good agreement with the local impedance measured in terms of only the normal contribution. At the periphery of the electrode, the impedance taking into account both normal and radial contributions differed significantly from the local impedance measured in terms of only the normal contribution. The radial impedance results at the periphery of the electrode are in good agreement with the usual explanation that the associated larger current density is attributed to the geometry of the electrode, which exhibits a greater accessibility at the electrode edge
On the de Haas-van Alphen effect in inhomogeneous alloys
We show that Landau level broadening in alloys occurs naturally as a
consequence of random variations in the local quasiparticle density, without
the need to consider a relaxation time. This approach predicts
Lorentzian-broadened Landau levels similar to those derived by Dingle using the
relaxation-time approximation. However, rather than being determined by a
finite relaxation time , the Landau-level widths instead depend directly
on the rate at which the de Haas-van Alphen frequency changes with alloy
composition. The results are in good agreement with recent data from three very
different alloy systems.Comment: 5 pages, no figure
A falls prevention programme to improve quality of life, physical function and falls efficacy in older people receiving home help services: study protocol for a randomised controlled trial
BACKGROUND:
Falls and fall-related injuries in older adults are associated with great burdens, both for the individuals, the health care system and the society. Previous research has shown evidence for the efficiency of exercise as falls prevention. An understudied group are older adults receiving home help services, and the effect of a falls prevention programme on health-related quality of life is unclear. The primary aim of this randomised controlled trial is to examine the effect of a falls prevention programme on quality of life, physical function and falls efficacy in older adults receiving home help services. A secondary aim is to explore the mediating factors between falls prevention and health-related quality of life.
METHODS:
The study is a single-blinded randomised controlled trial. Participants are older adults, aged 67 or older, receiving home help services, who are able to walk with or without walking aids, who have experienced at least one fall during the last 12 months and who have a Mini Mental State Examination of 23 or above. The intervention group receives a programme, based on the Otago Exercise Programme, lasting 12 weeks including home visits and motivational telephone calls. The control group receives usual care. The primary outcome is health-related quality of life (SF-36). Secondary outcomes are leg strength, balance, walking speed, walking habits, activities of daily living, nutritional status and falls efficacy. All measurements are performed at baseline, following intervention at 3 months and at 6 months' follow-up. Sample size, based on the primary outcome, is set to 150 participants randomised into the two arms, including an estimated 15-20% drop out. Participants are recruited from six municipalities in Norway.
DISCUSSION:
This trial will generate new knowledge on the effects of an exercise falls prevention programme among older fallers receiving home help services. This knowledge will be useful for clinicians, for health managers in the primary health care service and for policy makers
Transiting exoplanets from the CoRoT space mission VIII. CoRoT-7b: the first Super-Earth with measured radius
We report the discovery of very shallow (DF/F = 3.4 10-4), periodic dips in
the light curve of an active V = 11.7 G9V star observed by the CoRoT satellite,
which we interpret as due to the presence of a transiting companion. We
describe the 3-colour CoRoT data and complementary ground-based observations
that support the planetary nature of the companion. Methods. We use CoRoT color
information, good angular resolution ground-based photometric observations in-
and out- of transit, adaptive optics imaging, near-infrared spectroscopy and
preliminary results from Radial Velocity measurements, to test the diluted
eclipsing binary scenarios. The parameters of the host star are derived from
optical spectra, which were then combined with the CoRoT light curve to derive
parameters of the companion. We examine carefully all conceivable cases of
false positives, and all tests performed support the planetary hypothesis.
Blends with separation larger than 0.40 arcsec or triple systems are almost
excluded with a 8 10-4 risk left. We conclude that, as far as we have been
exhaustive, we have discovered a planetary companion, named CoRoT-7b, for which
we derive a period of 0.853 59 +/- 3 10-5 day and a radius of Rp = 1.68 +/-
0.09 REarth. Analysis of preliminary radial velocity data yields an upper limit
of 21 MEarth for the companion mass, supporting the finding.
CoRoT-7b is very likely the first Super-Earth with a measured radius.Comment: Accepted in Astronomy and Astrophysics; typos and language
corrections; version sent to the printer w few upgrade
UV and EUV Instruments
We describe telescopes and instruments that were developed and used for
astronomical research in the ultraviolet (UV) and extreme ultraviolet (EUV)
regions of the electromagnetic spectrum. The wavelength ranges covered by these
bands are not uniquely defined. We use the following convention here: The EUV
and UV span the regions ~100-912 and 912-3000 Angstroem respectively. The
limitation between both ranges is a natural choice, because the hydrogen Lyman
absorption edge is located at 912 Angstroem. At smaller wavelengths,
astronomical sources are strongly absorbed by the interstellar medium. It also
marks a technical limit, because telescopes and instruments are of different
design. In the EUV range, the technology is strongly related to that utilized
in X-ray astronomy, while in the UV range the instruments in many cases have
their roots in optical astronomy. We will, therefore, describe the UV and EUV
instruments in appropriate conciseness and refer to the respective chapters of
this volume for more technical details.Comment: To appear in: Landolt-Boernstein, New Series VI/4A, Astronomy,
Astrophysics, and Cosmology; Instruments and Methods, ed. J.E. Truemper,
Springer-Verlag, Berlin, 201
Construction, assembly and tests of the ATLAS electromagnetic end-cap calorimeters
The construction and the assembly of the two end-caps of the ATLAS liquid argon electromagnetic calorimeter as well as their test and qualification programs are described. The work described here started at the beginning of 2001 and lasted for approximately three years. The results of the qualification tests performed before installation in the LHC ATLAS pit are given. The detectors are now installed in the ATLAS cavern, full of liquid argon and being commissioned. The complete detectors coverage is powered with high voltage and readout
Performance of an endcap prototype of the ATLAS accordion electromagnetic calorimeter
The design and construction of a lead-liquid argon endcap calorimeter prototype using an accordion geometry and conceived as a sector of the inner wheel of the endcap calorimeter of the future ATLAS experiment at the LHC is described. The performance obtained using electron beam data is presented. The main results are an energy resolution with a sampling term below and a small local constant term, a good linearity of the response with the incident energy and a global constant term of 0.8\% over an extended area in the rapidity range of . These properties make the design suitable for the ATLAS electromagnetic endcap calorimeter
Performance of a large scale prototype of the ATLAS accordion electromagnetic calorimeter
A 2 m long prototype of a lead-liquid argon electromagnetic calorimeter with accordion-shaped electrodes, conceived as a sector of the barrel calorimeter of the future ATLAS experiment at the LHC, has been tested with electron and pion beams in the energy range 10 to 287 GeV. A sampling term of 10%/root E(GeV) was obtained for electrons in the rapidity range 0 < eta < 1, while the constant term measured over an area of about 1 m(2) is 0.69%. With a cell size of 2.7 cm the position resolution is. about 4 mm/root E(GeV)
Performance of the ATLAS electromagnetic calorimeter end-cap module 0
The construction and beam test results of the ATLAS electromagnetic end-cap calorimeter pre-production module 0 are presented. The stochastic term of the energy resolution is between 10% GeV^1/2 and 12.5% GeV^1/2 over the full pseudorapidity range. Position and angular resolutions are found to be in agreement with simulation. A global constant term of 0.6% is obtained in the pseudorapidity range 2.5 eta 3.2 (inner wheel)
- …
