44 research outputs found
The OPERA magnetic spectrometer
The OPERA neutrino oscillation experiment foresees the construction of two
magnetized iron spectrometers located after the lead-nuclear emulsion targets.
The magnet is made up of two vertical walls of rectangular cross section
connected by return yokes. The particle trajectories are measured by high
precision drift tubes located before and after the arms of the magnet.
Moreover, the magnet steel is instrumented with Resistive Plate Chambers that
ease pattern recognition and allow a calorimetric measurement of the hadronic
showers. In this paper we review the construction of the spectrometers. In
particular, we describe the results obtained from the magnet and RPC prototypes
and the installation of the final apparatus at the Gran Sasso laboratories. We
discuss the mechanical and magnetic properties of the steel and the techniques
employed to calibrate the field in the bulk of the magnet. Moreover, results of
the tests and issues concerning the mass production of the Resistive Plate
Chambers are reported. Finally, the expected physics performance of the
detector is described; estimates rely on numerical simulations and the outcome
of the tests described above.Comment: 6 pages, 10 figures, presented at the 2003 IEEE-NSS conference,
Portland, OR, USA, October 20-24, 200
Electromagnetic characterization of the 990 ton gapless magnets for the OPERA experiment
The instrumented targets of the OPERA neutrino experiment are complemented by two massive spectrometers based on gapless iron magnets. In 2006, a systematic assessment of their electromagnetic properties have been carried out. In this document, we report the results of such characterization and demonstrate that the achieved performance fulfill the physics requirements for the study of νμ→ντ oscillations
The instrumented magnets for the OPERA experiment: construction and commissioning
The design and construction of the 990-ton gapless iron magnets for the OPERA experiment represent a major challenge from the point of view of mechanics, electric and heat engineering. Two of such magnets have been built in a deep underground hall of the Gran Sasso laboratories between 2003 and 2006 and they have been switched on for the first time in March 2006. In this paper we discuss the construction and characterization of these devices. First experience with the CNGS beam are also reported. © 2007 Elsevier B.V. All rights reserved
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
First events from the CNGS neutrino beam detected in the OPERA experiment
The OPERA neutrino detector at the underground Gran Sasso Laboratory (LNGS)
was designed to perform the first detection of neutrino oscillations in
appearance mode, through the study of nu_mu to nu_tau oscillations. The
apparatus consists of a lead/emulsion-film target complemented by electronic
detectors. It is placed in the high-energy, long-baseline CERN to LNGS beam
(CNGS) 730 km away from the neutrino source. In August 2006 a first run with
CNGS neutrinos was successfully conducted. A first sample of neutrino events
was collected, statistically consistent with the integrated beam intensity.
After a brief description of the beam and of the various sub-detectors, we
report on the achievement of this milestone, presenting the first data and some
analysis results.Comment: Submitted to the New Journal of Physic
Technical Design Report for the: PANDA Micro Vertex Detector
This document illustrates the technical layout and the expected performance
of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect
charged particles as close as possible to the interaction zone. Design criteria
and the optimisation process as well as the technical solutions chosen are
discussed and the results of this process are subjected to extensive Monte
Carlo physics studies. The route towards realisation of the detector is
outlined.Comment: 189 pages, 225 figures, 41 table
Physics Performance Report for PANDA: Strong Interaction Studies with Antiprotons
To study fundamental questions of hadron and nuclear physics in interactions
of antiprotons with nucleons and nuclei, the universal PANDA detector will be
built. Gluonic excitations, the physics of strange and charm quarks and nucleon
structure studies will be performed with unprecedented accuracy thereby
allowing high-precision tests of the strong interaction. The proposed PANDA
detector is a state-of-the art internal target detector at the HESR at FAIR
allowing the detection and identification of neutral and charged particles
generated within the relevant angular and energy range. This report presents a
summary of the physics accessible at PANDA and what performance can be
expected.Comment: 216 page
Study of the effects induced by lead on the emulsion films of the OPERA experiment
The OPERA neutrino oscillation experiment is based on the use of the Emulsion
Cloud Chamber (ECC). In the OPERA ECC, nuclear emulsion films acting as very
high precision tracking detectors are interleaved with lead plates providing a
massive target for neutrino interactions. We report on studies related to the
effects occurring from the contact between emulsion and lead. A low
radioactivity lead is required in order to minimize the number of background
tracks in emulsions and to achieve the required performance in the
reconstruction of neutrino events. It was observed that adding other chemical
elements to the lead, in order to improve the mechanical properties, may
significantly increase the level of radioactivity on the emulsions. A detailed
study was made in order to choose a lead alloy with good mechanical properties
and an appropriate packing technique so as to have a low enough effective
radioactivity.Comment: 19 pages, 11 figure