14 research outputs found

    Lung ultrasound training: how short is too short? observational study on the effects of a focused theoretical training for novice learners

    No full text
    Abstract Background Lung ultrasound has been increasingly used in the last years for the assessment of patients with respiratory diseases; it is considered a simple technique, now spreading from physicians to other healthcare professionals as nurses and physiotherapists, as well as to medical students. These providers may require a different training to acquire lung ultrasound skills, since they are expected to have no previous experience with ultrasound. The aim of the study was to assess the impact of a short theoretical training focused on lung ultrasound pattern recognition in a population of novice nurse learners with no previous experience with ultrasound. Methods We included the nurses attending a critical care advanced course for nurses performed at the University of Pavia. Images’ interpretation skills were tested on two slide sets (a 25-clip set focused on B-pattern recognition and a 25-clip set focused on identification of pleural movement as lung sliding, lung pulse, lung point, no movement) before and after three 30-minute teaching modules dedicated to general ultrasound principles, B-lines assessment and lung sliding assessment. A cut off of 80% was considered acceptable for correctly interpreted images after this basic course. Results 22 nurses were enrolled (age 26.0 [24.0–28.0] years; men 4 (18%)); one nurse had previous experience with other ultrasound techniques, none of them had previous experience with lung ultrasound. After the training, the number of correctly interpreted clips improved from 3.5 [0.0–13.0] to 22.0 [19.0–23.0] (p < 0.0001) for B-pattern and from 0.5 [0.0–2.0] to 8.5 [6.0–12.0] (p < 0.0001) for lung sliding assessment. The number of correct answers for B-pattern recognition was significantly higher than for lung sliding assessment, both before (3.5 [0.0–13.0] vs. 0.5 [0.0–2.0]; p = 0.0036) and after (22.0 [19.0–23.0] vs. 8.5 [6.0–12.0]; p < 0.0001) the training. After the training, nurses were able to correctly recognize the presence or the absence of a B-pattern in 84.2 ± 10.3% of cases; lung sliding was correctly assessed in 37.1 ± 15.3% of cases. Conclusions Lung ultrasound is considered a simple technique; while a short, focused training significantly improves B-pattern recognition, lung sliding assessment may require a longer training for novice learners. Trial registration Not applicable

    Toward the development of a fully elastic mitral ring: Preliminary, acute, in vivo evaluation of physiomechanical behavior

    Get PDF
    ObjectivesThe optimal repair of functional mitral regurgitation is still debated. No device is able to simultaneously abolish mitral regurgitation and replicate natural mitral annular dynamics. We have tested a fully elastic mitral ring in an acute animal study with the purpose of evaluating (1) ring design and implantation technique, (2) elastic performance, and (3) acute effects on the native mitral annulus.MethodsTen healthy sheep underwent surgical implantation of mitral devices, the elastic component of which is represented by a helicoid metallic spring. Preimplantation and postimplantation echocardiographic parameter measurements to evaluate annular dynamics and ventricular function comprise mitral annular motion, systolic tissue Doppler imaging peak wave, transmitral pressure gradient, peak transmitral flow velocity, and ejection fraction. Postimplantation angiographic analysis allowed measurement of the mitral annular area and perimeter variations by means of segmentation of the radiopaque mitral device contour.ResultsNo significant difference in terms of ejection fraction (P = .13) and systolic tissue Doppler imaging peak wave (P = .87) was found before and after implantation. Mitral annular motion (1.16 cm) was preserved. The percentage of systolic annular reduction derived from angiographic analysis was 14.1% (range, 7.7%–19.7%) in terms of area and 7.2% (range, 4.9%–10.0%) in terms of perimeter.ConclusionsA mitral elastic ring, implantable by using a standard technique, acutely preserves mitral annular dynamics, allowing area and perimeter changes. Further chronic study is needed to verify the biocompatibility and durability of the device

    Implantation of an Elastic Ring at Equator of the Left Ventricle Influences Cardiac Mechanics in Experimental Acute Ventricular Dysfunction

    Get PDF
    ObjectivesWe hypothesize that the implantation of an endoventricular elastic ring at the left ventricle (LV) equatorial site will positively affect the cardiac mechanics in an experimental model of acute LV dysfunction.BackgroundChanges in the elastic properties of LV occur in the dilated and failing heart, contributing to overall cardiac mechanical dysfunction. No interventions are as yet specifically designed to improve LV elasticity in failing hearts.MethodsAcute LV enlargement and dysfunction was induced in 13 healthy sheep via the insertion of a large Dacron patch into the lateral wall. In 6 of these sheep, a customized elastic ring was implanted at the inner surface of the LV equator (ring group), and the remaining 7 served as control subjects (dysfunction group). Systolic and diastolic function was evaluated using echocardiography and pressure–volume (P–V) analysis.ResultsIn the ring group, both the maximum rate of pressure increase and the slope of end-systolic P–V relationship were significantly different from those without ring (1,718 ± 726 vs. 1,049 ± 269 and 1.25 ± 0.30 vs. 0.88 ± 0.19; both p < 0.05). Preload recruitable stroke work changed even more prominently (33 ± 11 vs. 17 ± 5; p = 0.005), along with stroke volume, ejection fraction, and stroke work. Although ring implantation had no effect on end-diastolic P–V relationship, it positively affected the active component of diastole: the maximum rate of pressure decrease declined significantly (p = 0.037). The time constant of relaxation tended to decrease (37 ± 8 vs. 44 ± 6; p = 0.088).ConclusionsImproving the elastic component of the LV at its equatorial site substantially augments contractility and early relaxation in acute systodiastolic LV dysfunction
    corecore