218 research outputs found

    Potts model on recursive lattices: some new exact results

    Full text link
    We compute the partition function of the Potts model with arbitrary values of qq and temperature on some strip lattices. We consider strips of width Ly=2L_y=2, for three different lattices: square, diced and `shortest-path' (to be defined in the text). We also get the exact solution for strips of the Kagome lattice for widths Ly=2,3,4,5L_y=2,3,4,5. As further examples we consider two lattices with different type of regular symmetry: a strip with alternating layers of width Ly=3L_y=3 and Ly=m+2L_y=m+2, and a strip with variable width. Finally we make some remarks on the Fisher zeros for the Kagome lattice and their large q-limit.Comment: 17 pages, 19 figures. v2 typos corrected, title changed and references, acknowledgements and two further original examples added. v3 one further example added. v4 final versio

    Verification Testing To Confirm VO2max Attainment in Inactive Women With Obesity

    Get PDF
    International Journal of Exercise Science 13(4): 1448-1458, 2020. Incidence of obesity is increasing worldwide which is deleterious to health due to its association with increased risk of cardiovascular disease, diabetes, and some cancers. Completion of regular physical activity in individuals with obesity increases maximal oxygen uptake (VO2max). However, whether individuals with obesity can exhibit ‘true’ VO2max is unresolved. This study examined efficacy of verification testing (VER) to identify ‘true’ VO2max in 17 inactive women with obesity (age, body fat, and VO2max = 37 ± 10 yr, 48.7 ± 3.5 %, and 19.4 ± 3.0 mL/kg/min, respectively). They performed ramp exercise (RAMP) to volitional fatigue followed by VER at 105 percent peak power output (%PPO) at baseline and after 3 and 6 wk of high intensity interval training. Results showed no difference in ramp and verification-derived VO2max (1.99 ± 0.37 L/min vs. 1.98 ± 0.32 L/min, 2.00 ± 0.40 L/min vs. 2.04 ± 0.38 L/min, and 2.08 ± 0.34 L/min vs. 2.08 ± 0.32 L/min at 0, 3 and 6 wk of training), although in 40 % of VER tests, VO2max was greater than the RAMP value. Overall, verification testing may be adopted as an additional approach to confirm ‘true’ VO2max attainment in obese women as ramp exercise frequently underestimates VO2max in this population

    Development of an Anger camera in Lanthanum Bromide for gamma-ray space astronomy in the MeV range

    No full text
    International audienceLanthanum bromide is a very promising scintillator material for the next generation of g-ray telescopes. We present in this paper first g-ray imaging results obtained by coupling a LaBr3 crystal with a position-sensitive 8×8 multianode photomultiplier tube to form a simple Anger camera module. The readout of the 64 signals is carried out with the most recent evolution of the MultiAnode ReadOut Chip (MAROC) which was initially designed for the luminometer of the ATLAS detector. Measured charge distributions are compared with detailed GEANT4 simulations that include the tracking of the optical photons produced in the scintillation crystal. The depth of interaction (d.o.i.) of 662-keV g-rays inside the crystal is derived from the charge distributions using an artificial neural network. We obtain for an irradiation at detector centre a mean standard deviation of the d.o.i. of 1.69 mm. Such a position-sensitive g-ray detector can form an innovative building block for a future space calorimete

    A new approach for almost automatic installation of elastic cloud infrastructures

    Get PDF
    In the context of the cloud infrastructures at the INFN computing center of Torino, we implemented new simplified tools based up on OpenNebula cloud manager for almost automatic deployment of standard cloud infrastructure, monitoring, maintenance, and VMs management within elastic cloud infrastructures. Such new tools for small and medium infrastructures could significantly improve their usability and efficiency by simplifying the installation and set up processes, providing easier access to elastic cloud technologies to sites with limited specific knowledge or dedicated manpower; introducing flexibility in a dynamic allocation of resources to the different stakeholders in one single infrastructure, maximizing the efficiency

    More than one shade of pink as a marker of early amelanotic/hypomelanotic melanoma

    Get PDF
    Amelanotic/hypomelanotic melanoma (AHM) may be difficult to diagnose because of a lack of pigmentation. To evaluate whether dermoscopy can be useful for the diagnosis of early AHM, 133 digital dermoscopic images of lesions histopathologically diagnosed as amelanotic/hypomelanotic superficial spreading melanoma with ≤1 mm thickness (AHSSMs) (n = 27), amelanotic/hypomelanotic non-melanocytic lesions (AHNMLs) (e.g., seborrhoeic keratosis and basal cell carcinoma) (n = 79), and amelanotic/hypomelanotic benign melanocytic lesions (AHBMLs) (e.g., compound and dermal nevi) (n = 27), were dermoscopically assessed by three blinded dermatologists. Using multivariate analysis, we found a significantly increased risk of diagnosing AHSSM versus AHNML and AHBML when the lesion was characterized by the presence of more than one shade of pink (odds ratio [OR] 37.11), irregular dots/globules (OR 23.73), asymmetric pigmentation (OR 8.85), and structureless pattern (OR 7.33). In conclusion, dermoscopy may improve early AHM detection, discriminating AHSSM from amelanotic/hypomelanotic non melanoma lesion

    The Effects of Park Based Interventions on Health: The Italian Project “Moving Parks”

    Get PDF
    Obesity and physical inactivity are global health problems responsible for the risk increment of noncommunicable diseases. To overcome these problems, interventions aimed at increasing physical activity (PA) are necessary. Green space can have a positive influence on promoting PA, so, the aim of the present study was to assess the effectiveness of the project “The moving parks project”, which provides for the administration of PA to citizens within Bologna’s parks (Italy). An ad hoc questionnaire was administered before and after three months of outdoor PA. A total of 329 adult subjects participated in the survey. At follow-up, all psychosocial parameters showed an improvement, with a reduction in the state of tension, sadness and fatigue, and an improvement in the state of energy, serenity, and vitality. The impact of the interventions carried out in the “Moving Parks project” was positive and appears to be a good strategy for improving health outcomes

    Physiological and perceptual responses to sprint interval exercise using arm versus leg cycling ergometry

    Get PDF
    Increases in power output and maximal oxygen consumption (VO2max) occur in response to sprint interval exercise (SIE), but common use of “all-out” intensities presents a barrier for many adults. Furthermore, lower-body SIE is not feasible for all adults. We compared physiological and perceptual responses to supramaximal, but “non-all-out” SIE between leg and arm cycling exercise. Twenty-four active adults (mean ± SD age: [25 ± 7] y; cycling VO2max: [39 ± 7] mL·kg−1·min−1) performed incremental exercise using leg (LCE) and arm cycle ergometry (ACE) to determine VO2max and maximal work capacity (Wmax). Subsequently, they performed four 20 s (s) bouts of SIE at 130 % Wmax on the LCE or ACE at cadence = 120–130 rev/min, with 2 min (min) recovery between intervals. Gas exchange data, heart rate (HR), blood lactate concentration (BLa), rating of perceived exertion (RPE), and affective valence were acquired. Data showed significantly lower (p  0.42), and lowest affective valence recorded (2.0 ± 1.8) was considered “good to fairly good”. Data show that non “all-out” ACE elicits lower absolute but higher relative HR and VO2 compared to LCE. Less aversive perceptual responses could make this non-all-out modality feasible for inactive adults

    Fluid-structure interaction simulation of prosthetic aortic valves : comparison between immersed boundary and arbitrary Lagrangian-Eulerian techniques for the mesh representation

    Get PDF
    In recent years the role of FSI (fluid-structure interaction) simulations in the analysis of the fluid-mechanics of heart valves is becoming more and more important, being able to capture the interaction between the blood and both the surrounding biological tissues and the valve itself. When setting up an FSI simulation, several choices have to be made to select the most suitable approach for the case of interest: in particular, to simulate flexible leaflet cardiac valves, the type of discretization of the fluid domain is crucial, which can be described with an ALE (Arbitrary Lagrangian-Eulerian) or an Eulerian formulation. The majority of the reported 3D heart valve FSI simulations are performed with the Eulerian formulation, allowing for large deformations of the domains without compromising the quality of the fluid grid. Nevertheless, it is known that the ALE-FSI approach guarantees more accurate results at the interface between the solid and the fluid. The goal of this paper is to describe the same aortic valve model in the two cases, comparing the performances of an ALE-based FSI solution and an Eulerian-based FSI approach. After a first simplified 2D case, the aortic geometry was considered in a full 3D set-up. The model was kept as similar as possible in the two settings, to better compare the simulations' outcomes. Although for the 2D case the differences were unsubstantial, in our experience the performance of a full 3D ALE-FSI simulation was significantly limited by the technical problems and requirements inherent to the ALE formulation, mainly related to the mesh motion and deformation of the fluid domain. As a secondary outcome of this work, it is important to point out that the choice of the solver also influenced the reliability of the final results
    corecore