47 research outputs found

    Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study

    Get PDF
    To assess and compare the accuracies of intraoral scanners (IOS) and stereophotogrammetry (SPG) devices for complete-arch digital implant impressions.A 4-analog model was digitized using a desk scanner to obtain a reference file. Thirty test scans were conducted using the investigated IOS device, while an additional 30 scans were performed using the SPG device. Using the best-fit algorithm, the resulting 60 test files were aligned with the reference file. Linear (ΔX, ΔY, and ΔZ-axis) and angular deviations (ΔANGLE) were evaluated. Three-dimensional (3D) deviation was calculated based on the Euclidean distance (ΔEUC). The analysis was stratified according to the scanning device and implant position. Fisher's F and t-tests were used to compare the variances and expected values of the two scanning systems.IOS expressed a higher 3D (ΔEUC) mean deviation than SPG (52.8 ”m vs. 33.4 ”m, P < 0.0001), with extreme measurements up to 181.9 ”m. A significantly higher standard deviation (SD) was associated with IOS (37.1 ”m vs. 17.7 ”m, P < 0.0001). Considering angular deviations, the IOS showed slightly higher angular mean deviations (ΔANGLE) than the SPG (0.28° vs. 0.24°, P = 0.0022), with extreme measurements of up to 0.73°. The SPG SD values were significantly lower than the IOS SD values (0.14° vs. 0.04°, P < 0.0001).The SPG showed significantly higher 3D and angular accuracies for complete arch implant impressions, with consistent repeatability. IOS scanning revealed significantly higher extreme deviations exceeding the acceptable threshold value. Despite study limitations, SPG appears more feasible than IOS for complete-arch digital implant impressions

    Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study

    Get PDF
    Objectives: To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo. Materials and Methods: Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at.05. Results: A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 ÎŒm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of −49.60 ÎŒm (p =.0143; SD 138.15) and mean ΔANGLE difference of −0.40° (p <.0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p =.0162) and ΔANGLE (p =.0001) only for impression devices, with SPG performing better. Conclusions: SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing. © 2023 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd

    Functional Neuromyofascial Activity: Interprofessional Assessment to Inform Person-Centered Participative Care-An Osteopathic Perspective

    Get PDF
    : Introduction: Health professionals and bodyworkers may be pivotal in promoting prevention programs, providing tailored advice and guidance to patients' adherence to self-care strategies, such as physical activity. Contemporary evidence encourages manual therapists to involve patients in decision-making and treatment procedures integrating passive and active approaches in treatment planning. This manuscript provides a definition and applications of neuromyofascial movement patterns, discusses the significance of functional assessment, and gives an example of clinical applications in the osteopathic field to highlight how this assessment can promote interdisciplinarity. Methods: The reporting framework used in the current manuscript followed guidelines for writing a commentary. Results: The manuscript highlights the crucial role that the neuromyofascial system plays in human movement and overall well-being and the importance of a functional neuromyofascial activity assessment in the context of person-centered participative care. Conclusions: Understanding individual neuromyofascial patterns could help healthcare practitioners, movement specialists, and bodyworkers in tailoring treatment plans, meeting patients' unique needs, and promoting a more effective personalized approach to care. The current perspective could spark debates within the professional community and provide a research roadmap for developing an evidence-informed interprofessional framework

    Technical analysis of a renewable woody biomass generator/electrolyzer poly-generative system

    Get PDF
    In the REPowerEU plan, the European Commission has envisaged a rapid reduction in dependence on fossil fuels, an acceleration of the green transition and has shown its willingness to tackle the climate crisis by resorting to greater and better use of renewable energy sources. Furthermore, from 2035 the “Fit for 55” climate package aims to reduce emissions of pollutants and climate-altering gas emissions and to encourage the diffusion of new pure electric or fuel cell hybrid electric vehicles. In this context, this article deals with a poly-generative energy system for the production of H2, electric and thermal powers. It is able to satisfy the new vehicles needs and/or the electric/thermal loads of a rural building located in Rende (Italy, Lat. 39.3°N) on two typical winter and summer days. The poly-generative system is mainly composed of an energy system fed by woody biomass in a cogenerative arrangement, a photovoltaic system and a PEM electrolyzer. Technical analysis of the system shows that for the mixed fleet of 30 vehicles the output electrical and thermal powers and hydrogen production are respectively of about 50 kW, 97 kW and 9.23 kg. Furthermore, the system covers totally the electric load on summer days and the thermal load for hot water production in the summer and winter days

    Short versus standard treatment with pegylated interferon alfa-2A plus ribavirin in patients with hepatitis C virus genotype 2 or 3: the cleo trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with chronic hepatitis C virus (HCV) genotype 2 or 3, 24 weeks' treatment with pegylated interferon alfa (PEG-IFN-alpha) and ribavirin induces a sustained virological response (SVR) in almost 80% of cases. Evidence suggests that a similar response rate may be obtained with shorter treatment periods, especially in patients with a rapid virological response (RVR). The aim of this study was to compare the efficacy of 12 or 24 weeks of treatment in patients with chronic HCV genotype 2 or 3 and to identify patients suitable for 12 weeks treatment.</p> <p>Methods</p> <p>Two hundred and ten patients received PEG-IFN-alpha-2a (180 ug/week) and ribavirin (800-1200 mg/day) for 4 weeks. Patients with a RVR (HCV RNA not detectable) were randomized (1:1) to either 12 (group A1) or 24 (group A2) weeks of combination therapy. Patients without a RVR continued with 24-weeks' combination therapy (group B). HCV RNA was monitored at weeks 4, 8, 12, and 24, and at week 24 post-treatment.</p> <p>Results</p> <p>At study end, end of treatment response (ETR) was observed in 62 (86%) patients of group A1 and in 55 (77%) patients of group A2 (p < 0.05) Relapse rate was 3% each in groups A1 and A2, and 6% in group B. Among patients with a HCVRNA test 24 weeks after the end of treatment, SVR was observed in 60 (83%) of group A1 patients and in 53 (75%) of group A2 patients. Rapid virological response, low baseline HCV RNA levels, elevated alanine aminotransferase levels and low fibrosis score, were the strongest covariates associated with SVR, independent of HCV genotype. No baseline characteristic was associated with relapse.</p> <p>Conclusion</p> <p>In HCV patients with genotype 2 or 3, 12-week combination therapy is as efficacious as 24-week therapy and several independent covariates were predictive of SVR.</p> <p>Trial registration</p> <p>Trial number ISRCTN29259563</p

    Evaluation of appendicitis risk prediction models in adults with suspected appendicitis

    Get PDF
    Background Appendicitis is the most common general surgical emergency worldwide, but its diagnosis remains challenging. The aim of this study was to determine whether existing risk prediction models can reliably identify patients presenting to hospital in the UK with acute right iliac fossa (RIF) pain who are at low risk of appendicitis. Methods A systematic search was completed to identify all existing appendicitis risk prediction models. Models were validated using UK data from an international prospective cohort study that captured consecutive patients aged 16–45 years presenting to hospital with acute RIF in March to June 2017. The main outcome was best achievable model specificity (proportion of patients who did not have appendicitis correctly classified as low risk) whilst maintaining a failure rate below 5 per cent (proportion of patients identified as low risk who actually had appendicitis). Results Some 5345 patients across 154 UK hospitals were identified, of which two‐thirds (3613 of 5345, 67·6 per cent) were women. Women were more than twice as likely to undergo surgery with removal of a histologically normal appendix (272 of 964, 28·2 per cent) than men (120 of 993, 12·1 per cent) (relative risk 2·33, 95 per cent c.i. 1·92 to 2·84; P < 0·001). Of 15 validated risk prediction models, the Adult Appendicitis Score performed best (cut‐off score 8 or less, specificity 63·1 per cent, failure rate 3·7 per cent). The Appendicitis Inflammatory Response Score performed best for men (cut‐off score 2 or less, specificity 24·7 per cent, failure rate 2·4 per cent). Conclusion Women in the UK had a disproportionate risk of admission without surgical intervention and had high rates of normal appendicectomy. Risk prediction models to support shared decision‐making by identifying adults in the UK at low risk of appendicitis were identified

    The smiling scan technique: Facially driven guided surgery and prosthetics.

    No full text
    PURPOSE:To introduce a proof of concept technique and new integrated workflow to optimize the functional and esthetic outcome of the implant-supported restorations by means of a 3-dimensional (3D) facially-driven, digital assisted treatment plan. METHODS:The Smiling Scan technique permits the creation of a virtual dental patient (VDP) showing a broad smile under static conditions. The patient is exposed to a cone beam computed tomography scan (CBCT), displaying a broad smile for the duration of the examination. Intraoral optical surface scanning (IOS) of the dental and soft tissue anatomy or extraoral optical surface scanning (EOS) of the study casts are achieved. The superimposition of the digital imaging and communications in medicine (DICOM) files with standard tessellation language (STL) files is performed using the virtual planning software program permitting the creation of a VDP. CONCLUSIONS:The smiling scan is an effective, easy to use, and low-cost technique to develop a more comprehensive and simplified facially driven computer-assisted treatment plan, allowing a prosthetically driven implant placement and the delivery of an immediate computer aided design (CAD) computer aided manufacturing (CAM) temporary fixed dental prostheses (CAD/CAM technology)
    corecore