107 research outputs found

    CHANGING NURSING CARE TIME AS AN EFFECT OF CHANGED CHARACTERISTICS OF THE DIALYSIS POPULATION

    Get PDF
    Background The population of dialysis patients is ageing. Dialysis nurses are confronted with geriatric patients with multiple comorbidities. Nurses are confronted with an increasing burden of care. Objectives The present study focused on the question of whether, over time, the increasing age and comorbidities of the haemodialysis population increased nursing care time. Furthermore, we studied potential changes in the predictors of the required nursing time. Design Observational study. Participants A total of 980 dialysis patients from 12 dialysis centres were included. Measurements Nurses filled out the classification tool for each patient and completed a form for reporting patient characteristics for groups of relevant haemodialysis patients at baseline and after 1 and four years. Changes in patient and dialysis characteristics were analysed, as well as the estimated nursing care time needed. Results An increase in the nursing time needed for dialysis was largely due to decreased mobility, closing of the vascular access and a greater need for psychosocial attention and was most strongly present in incident dialysis patients. The time needed for dialysis decreased as patient participation increased and vascular access changed from catheters to fistulae. Over the four-year period, the average overall needed nursing care time per haemodialysis session did not change. Conclusions Our study shows that the average nursing time needed per patient did not change in the four-year observation period. However, more time is required for incident patients; thus, if a centre has high patient turnover, more nursing care time is needed.</p

    Resonant Auger spectroscopy at the L2,3 shake-up thresholds as a probe of electron correlation effects in nickel

    Full text link
    The excitation energy dependence of the three-hole satellites in the L3-M4,5M4,5 and L2-M4,5M4,5 Auger spectra of nickel metal has been measured using synchrotron radiation. The satellite behavior in the non-radiative emission spectra at the L3 and L2 thresholds is compared and the influence of the Coster-Kronig channel explored. The three-hole satellite intensity at the L3 Auger emission line reveals a peak structure at 5 eV above the L3 threshold attributed to resonant processes at the 2p53d9 shake-up threshold. This is discussed in connection with the 6-eV feature in the x-ray absorption spectrum.Comment: 8 pages, 4 figures; http://prb.aps.org/abstract/PRB/v58/i7/p3677_

    Electronic Structure of Transition Metals Fe, Ni and Cu in the GW Approximation

    Full text link
    The quasiparticle band structures of 3d transition metals, ferromagnetic Fe, Ni and paramagnetic Cu, are calculated by the GW approximation. The width of occupied 3d valence band, which is overestimated in the LSDA, is in good agreement with experimental observation. However the exchange splitting and satellite in spectra are not reproduced and it is required to go beyond the GW approximation. The effects of static screening and dynamical correlation are discussed in detail in comparison with the results of the static COHSEX approximation. The dynamical screening effects are important for band width narrowing.Comment: 4 pages, 3 figure

    Consumer price indexes: an analysis of heterogeneity across sub-populations

    Get PDF
    La rilevanza dell'Indece dei Prezzi al Consumo quale misura dell'inflazione è stata a lungo dibattuta in particolare esminando le differenti cause di distorsione dovute all'utilizzo di un paniere fisso di beni e servizi. Di conseguenza la letteratura ha proposto indici dei prezzi sperimentali per particolari sottogruppi di popolazioni. tali indici hanno rilevanza ai fini della politica economica e sociale, poiché è probabile che differenti gruppi di popolazione abbiano comportamenti nei consumi differenti dalla media, ad esempio i consumatori poveri (Garner, Johnson & Kokoski, 1996) e quelli anziani (Stewart, 2008). Lo scopo di questo lavoro è quello di esaminare le possibilità offerte da metodi di costruzione alternativi degli Indici dei Prezzi al Consumo ai fini di cogliere la variabilità dei tassi di inflazione relativi a differenti categorie di consumatori.The soundeness of Consumer Price Indexes (CPI) as a measure of inflation has long been debeate, focusing on the different sources of bias inherent to use of a constant basket of goods and services. Thus experimental consumer price indexes have been proposed for targeted sub-populations specifically relevant for social and economic policy, that are likely to have consumption patterns different from yhe average, i.e poor (Garner, Johnson & Kokoski, 1996) and elderly (Stewart, 2008)houseolds. Aim of this work is to investigate the possibilities offered by alternative methods of construction of consumer price indices in order to capture the variability of inflation rates facing different houseolds' types

    Fluoride content and recharge ability of five glassionomer dental materials

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The relationship between fluoride content and fluoride release for glass-ionomer cements is not well understood. The aim of this laboratory study was: to determine the fluoride concentrations at the surfaces of glass-ionomer materials with respect to different storage media and different pH environments; to examine the recharge ability of the materials after NaF immersion; and to assess the morphological changes at the material surfaces using scanning electron microscope and energy dispersive spectroscopic techniques (SEM/EDS).</p> <p>Methods</p> <p>Five glass-ionomer materials, Fuji Triage (FT), Fuji II LC (FII), Fuji VIII (FVIII), Fuji IX GP (FIX), and Ketac N100 (KN), were analyzed in this study. Resin-based fluoride releasing material Helioseal F (HSF) was used as a comparison material. The sample consisted of 120 cured cement disks (n = 20 disks of each tested material, 10 × 1.5 mm). Five disks of each material were stored in 4 different storage media (I- saline, II- acidic solution ph = 2.5, III- acid solution ph = 5.5, IV- NaF solution (c = 500/106). After 7 days, two disks of each material were transferred from media I, II and III to the NaF solution for 3 min. EDS analysis was conducted in 3 randomly selected spots of each experimental disk. SEM was used to determine morphological characteristics of the material surface. Differences between the experimental groups have been analyzed using Student's t-test with the level of significance set at p < 0.001.</p> <p>Results</p> <p>FT showed the highest fluoride content at the surface of the material. The lowest amounts of fluoride ions were detected at the surfaces of the FT disks stored at low pH environments, and this difference was statistically significant (p < 0.001). Glass-ionomers showed significantly higher fluoride concentrations when compared to the HSF (p < 0.001). After immersion in the NaF solution, fluoride concentrations at the surfaces of the disks increased when compared with previous storage media (FT>FVIII>KN>FII>FIX). SEM analysis of the surface morphology revealed numerous voids, cracks and microporosities in all experimental groups, except for KN and HSF. More homogenous material structure with more discrete cracks was observed in samples stored at neutral pH environment, compared to disks stored in acidic solutions.</p> <p>Conclusion</p> <p>The tested materials could be considered as promising dental materials with potential prophylactic characteristics due to their relatively high fluoride content, but also the ability to extensively reabsorb fluoride ions, especially in acidic environments.</p

    Spared unconscious influences of spatial memory in diencephalic amnesia

    Get PDF
    Spatial memory is crucial to our daily lives and in part strongly depends on automatic, implicit memory processes. This study investigates the neurocognitive basis of conscious and unconscious influences of object–location memory in amnesic patients with Korsakoff’s syndrome (N = 23) and healthy controls (N = 18) using a process-dissociation procedure in a computerized spatial memory task. As expected, the patients performed substantially worse on the conscious memory measures but showed even slightly stronger effects of unconscious influences than the controls. Moreover, a delayed test administered after 1 week revealed a strong decline in conscious influences in the patients, while unconscious influences were not affected. The presented results suggest that conscious and unconscious influences of spatial memory can be clearly dissociated in Korsakoff’s syndrome

    Comparative study of the analysis of seized samples by GC-MS, 1H NMR and FT-IR spectroscopy within a Night-Time Economy (NTE) setting

    Get PDF
    Rapid analysis of surrendered or seized drug samples provides important intelligence for health (e.g. treatment or harm reduction), and custodial services. Herein, three in-situ techniques, GC-MS, 1H NMR and FT-IR spectroscopy, with searchable libraries, are used to analyse 318 samples qualitatively, using technique specific library-based searches, obtained over the period 24th – 29th August 2019. 259 samples were identified as consisting of a single component, of which cocaine was the most prevalent (n = 158). Median match scores for all three techniques were ≥ 0.84 and showed agreement except for metformin (n = 1), oxandrolone (identified as vitamin K by IR (n = 4)), diazepam (identified as zolpidem by FT-IR (n = 2)) and 2-Br-4,5-DMPEA (n = 1), a structural isomer of 2C-B identified as a polymer of cellulose (cardboard) by FT-IR. 51 samples were found to consist of two or more components, of which 49 were adulterated cocaine samples (45 binary and 4 tertiary samples). GC-MS identified all components present in the 49 adulterated cocaine samples, whereas IR identified only cocaine in 88 % of cases (adulterant only = 12 %). The breakdown for 1H NMR spectroscopy was all components identified (51 %), cocaine only (33 %), adulterant only (10 %), cocaine and one adulterant (tertiary mixtures only, 6 %)
    corecore