7 research outputs found

    The Review of Materials for Energy Harvesting

    Get PDF
    This paper presents a short review of the piezoelectric materials in energy harvesting. Energy harvesting principle, as the method for obtaining energy from environment has been described. Materials and material combinations for creating an energy harvesting composites are discussed, such as ceramic- and polymer-based composites and their mechanical properties. The list of the mostly used piezoelectric materials is presented and elaborated. Possible applications of the energy harvesting materials are discussed, including nanogenerators, biosensors and biomedical applications.10.13039/100010686-EIT's HEIAccepted for publishin

    Electrospinning As The Fabrication Technology For The Energy Harvesting Composites

    Get PDF
    This paper presents the electrospinning technology as used for the fabrication of the energy harvesting composites, including the review of ceramic-based and polymer-based piezoelectric composites and their electrical outputs for the energy harvesting applications. Energy harvesting is a method for obtaining electrical energy from the environment to be used for powering autonomous electronic devices. Current trend of reducing the size of the devices has led to the increasing number of new energy harvesting materials. Basic principles of fiber fabrication via electrospinning were presented, as well as material characterization methods. The special focus was given to the electrical properties of energy harvesting composites with a review of methods for detecting and measuring electrical outputs of these materials. Electrical performance of the electrospun piezoelectric nanogenerators was discussed.SMART-2M, Innovation Capacity Building for Higher Education in Industry 4.0 and Smart Manufacturing, European Institute of Innovation and Technology (EIT), the European Union’s Horizon 2020 research and innovation program under grant agreement 777204 and projects No. 451-03-9/2021-14/200107 and No. 451-03-9/2021-14/200378, Ministry of Education, Science and Technological Development, SerbiaPublishe

    Solution of fluid flow through the left heart ventricle

    No full text
    © 2019 Published by the Serbian Academic Center. Finite element method (FEM) has proved to be very successful in solving complex problems in engineering. In medicine, FEM found a special application in simulation of real problems and their solution while eliminating the need of learning from examples. In this paper, FEM was used with viscous fluid dynamics to simulate the function of left heart ventricle. Theoretical fundamentals of FEM and heart function were given. The paper represents illustrative example for educational purposes

    Clinical effectiveness of primary prevention implantable cardioverter-defibrillators: results of the EU-CERT-ICD controlled multicentre cohort study

    No full text
    Aims: The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter-Defibrillators (EU-CERT-ICD), a prospective investigator-initiated, controlled cohort study, was conducted in 44 centres and 15 European countries. It aimed to assess current clinical effectiveness of primary prevention ICD therapy. Methods and results: We recruited 2327 patients with ischaemic cardiomyopathy (ICM) or dilated cardiomyopathy (DCM) and guideline indications for prophylactic ICD implantation. Primary endpoint was all-cause mortality. Clinical characteristics, medications, resting, and 12-lead Holter electrocardiograms (ECGs) were documented at enrolment baseline. Baseline and follow-up (FU) data from 2247 patients were analysable, 1516 patients before first ICD implantation (ICD group) and 731 patients without ICD serving as controls. Multivariable models and propensity scoring for adjustment were used to compare the two groups for mortality. During mean FU of 2.4 ± 1.1 years, 342 deaths occurred (6.3%/years annualized mortality, 5.6%/years in the ICD group vs. 9.2%/years in controls), favouring ICD treatment [unadjusted hazard ratio (HR) 0.682, 95% confidence interval (CI) 0.537–0.865, P = 0.0016]. Multivariable mortality predictors included age, left ventricular ejection fraction (LVEF), New York Heart Association class <III, and chronic obstructive pulmonary disease. Adjusted mortality associated with ICD vs. control was 27% lower (HR 0.731, 95% CI 0.569–0.938, P = 0.0140). Subgroup analyses indicated no ICD benefit in diabetics (adjusted HR = 0.945, P = 0.7797, P for interaction = 0.0887) or those aged ≥75 years (adjusted HR 1.063, P = 0.8206, P for interaction = 0.0902). Conclusion: In contemporary ICM/DCM patients (LVEF ≤35%, narrow QRS), primary prophylactic ICD treatment was associated with a 27% lower mortality after adjustment. There appear to be patients with less survival advantage, such as older patients or diabetics.peerReviewe

    Rationale and design of the EU-CERT-ICD prospective study: comparative effectiveness of prophylactic ICD implantation

    Get PDF
    AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value. METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.peerReviewe

    Rationale and design of the EU‐CERT‐ICD prospective study:comparative effectiveness of prophylactic ICD implantation

    No full text
    Abstract Aims: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU‐CERT‐ICD) aims to assess its current clinical value. Methods and results: The EU‐CERT‐ICD is a prospective investigator‐initiated non‐randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non‐randomized control group). The primary endpoint is all‐cause mortality; the co‐primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost‐effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12‐lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years. Conclusions: The EU‐CERT‐ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers
    corecore